8. errOr cOdes

errOr
descriptiOn
cOde
F01
The battery voltage is still under 10V (for a 12V battery)
or 5V (for a 6V battery) after 2 hours of charging.
F02
The charger cannot desulphate the battery.
F03
The battery was unable to reach the "full charged"
voltage.
F04
The connections to the battery are reversed.
F05
The battery was unable to keep the battery fully
charged in maintain mode.
F06
The charger detected that the battery may be getting too
hot (thermal runaway).
If you get an error code, check the connections and settings and/or replace the battery.

9. trOUbleshOOting

prOblem
pOssible cAUse
ConneCTed
led is
The battery is not connected correctly.
not on.
Battery voltage is at zero volts.
Input fuse is blown.
output breaker has tripped.
CHARGING
LED is
Charger is in Abort Mode
flashing.
Battery is sulphated.
Battery is defective.
FULL CHARGE
LED
Surface charge voltage is high.
is on, but battery is not
fully charged.
Battery voltage is very low
and the charger detects it as
6V not 12V.
All LEDs are lit in an
A button may have been pressed while the
erratic manner.
charger was being plugged in.
enVirOnment prOtectiOn
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Weee regUlAtiOns
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7Ar
01284 757500
© Jack Sealey limited
01284 703534
sales@sealey.co.uk
Original Language Version
cAUse
Could be caused by trying to charge a 6 volt battery on the
12V setting, or the battery could be defective; have it checked
or replaced.
The battery could not be desulphated; have it checked or
replaced.
Could be caused by trying to charge a large battery or bank
of batteries on too low of a current setting, or the battery may
have shorted cell. Try again with a higher current setting, or
get the battery checked or replaced.
The battery is connected backwards. Unplug the charger and
reverse the connections to the battery.
The battery won't hold a charge. Could be caused by a drain
on the battery, or the battery could be defective. make sure
there are no loads on the battery. If there are, remove them. If
there are none, have the battery checked or replaced.
The charger automatically shuts the current off if it detects
the battery may be getting too hot or the battery may have
a shorted cell. Have the battery checked or replaced.
sOlUtiOn
Check for correct connection to the battery.
Turn off everything in the car and try to connect again.
Replace the fuse (5 Amp fuse).
Push button to reset the breaker.
Unplug the charger from the mains supply and plug it
back in.
Use
(Desulphation Mode) for 8 hours.
Have the battery checked.
Replace the battery.
Unplug the charger from the mains supply and plug it
back in.
Unplug the charger from the mains supply and plug it
back in, without touching the control board.
www.sealey.co.uk