  • Page 1 ProCash 2050xe USB Installation Guide...
  • Page 2 WINCOR NIXDORF International GmbH Handbuchredaktion BD PSD 43 D - 33094 Paderborn Germany Fax: +49 (0) 52 51 693-62 09 E-mail: manuals.hardware@wincor-nixdorf.com ... any technical questions or problems? Please contact your local representative. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 3 ProCash 2050xe USB Installation Guide Edition June 2010...
  • Page 4 All names of hardware and software products mentioned in this manual are trade names and/or trademarks of their respective manufacturers. This manual was produced using paper treated with chlorine-free bleach. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 5: Table Of Contents

    General safety precautions ..............2 Planning the Installation ................7 Device dimensions (35 mm (1.38") tunnel) ..........7 ProCash 2050xe USB with 4-cassette dispenser ......... 8 Device without illuminated signage ..........8 Device with illuminated signage ............. 10 Device with illuminated signage and lower light case ....11 ProCash 2050xe USB with 5-cassette dispenser .......
  • Page 6 Dimensions of safe attachment points ........... 61 Dimensions of cable areas ............. 63 Finding the required installation rack ........... 65 Tear-off sensor ..................67 Drilling diagrams ..................67 Drilling diagram for 25 mm (0.98") installation frame ......68 ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 7 Remote status indicator ............... 75 Dimensions of illuminated logos ............... 76 Transport path requirements ..............77 Transport measurements for ProCash 2050xe USB ......78 ProCash 2050xe USB with 4-cassette dispenser ......78 ProCash 2050xe USB with 5-cassette dispenser ......80 ProCash 2050xe USB with 6-cassette dispenser ......
  • Page 8 Pushing the cash media dispenser (CMD-V4) down ....139 Installing the power and data cables in the device ....... 139 Further procedure for CEN installation ......... 140 General information ..............140 Installing the tunnel frame ............... 141 ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 9 Notes concerning installation preparation ......... 175 Technical data ..................177 General installation conditions ............177 Electrical characteristics of the supply network ......177 Device conditions ................. 178 Installation specifications ............. 180 Environmental conditions ............. 182 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 10 Environmentally and recycling-friendly product development ... 186 Saving energy ..................187 Disposing of used consumables ............187 Labels on plastic case parts .............. 187 Returning, recycling and disposing of used units and consumables ..................187 ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 11 Interference Causing Standards Equipment Standards Canadian Standards International Association Electrotechnical Commission International Protection International Organization German Institute for for Standardization Standardization Data Transmission L N PE Line Neutral Protective Earth European Community 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 12 CIM 86) Remote Status Indicator SELV Safety Extra-Low Voltage TN network Power supply network in accordance with EN 60950 Underwriters Laboratories Inc. Uninterruptible Power Supply Association of Property Insurance Companies VIII ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 13: Introduction

    Introduction This installation guide provides all the information you require to plan and prepare installation and to set up the ProCash 2050xe USB. The ProCash 2050xe USB is available in the following versions: − ProCash 2050xe USB with a 35 mm (1.38") tunnel:...
  • Page 14: Important Safety Precautions

    − Remove the shipping restraints inside the unit which secure its components during transportation if necessary for the installation (see enclosed information sheet). General safety precautions This device complies with the relevant safety regulations for information processing equipment. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 15 − During a thunderstorm, data transmission lines must not be connected or disconnected. − Always keep the device's vents free from obstruction to ensure proper air circulation and to prevent malfunctions resulting from overheating. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 16 (e. g. EMA connection, relay panel for external features). − To clean and maintain the device only use cleaning agents approved by WINCOR NIXDORF International GmbH (see chapter "Appendix" in the operating manual). Repairs Repair work may only be carried out by authorized personnel.
  • Page 17 − Do not allow the battery to come into contact with water or fire. Replace only with the same or an equivalent type recommended by WINCOR NIXDORF International GmbH (see chapter "Appendix", section "Consumables" in the operating manual). Dispose of used batteries in compliance with national regulations and the manufacturer's specifications.
  • Page 18 Introduction ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 19: Planning The Installation

    Make sure that the values are neither higher nor lower than the specified values to prevent irreparable damage to the device. WINCOR NIXDORF International GmbH is not liable for any damage to the device resulting from failure to meet these conditions.
  • Page 20: Procash 2050Xe Usb With 4-Cassette Dispenser

    Device dimensions (35 mm (1.38") tunnel) Planning the Installation ProCash 2050xe USB with 4-cassette dispenser Device without illuminated signage Safe width 600 mm (23.62") (8.46") 600 (23.62") 72/43* 848 (33.39") (2.83/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69")
  • Page 21 Planning the Installation Device dimensions (35 mm (1.38") tunnel) Safe width 450 mm (17.72") (8.46") 450 (17.72") 738 (29.06") 600 (23.62") 1098 (43.23") (4.33") 1133 (44.61") 13.5 (0.53") (19.69") 634 (24.96") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 22: Device With Illuminated Signage

    Device with illuminated signage (8.46") (19.06") (1.97") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 23: Device With Illuminated Signage And Lower Light Case

    Device with illuminated signage and lower light case (8.46") (19.06") (1.97") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 24: Procash 2050Xe Usb With 5-Cassette Dispenser

    Device dimensions (35 mm (1.38") tunnel) Planning the Installation ProCash 2050xe USB with 5-cassette dispenser Device without illuminated signage (8.46") 848 (33.39") 72/43* (1.83") (2.83"/1.69"*) 1208 (47.56") (23.62") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max.
  • Page 25: Device With Illuminated Signage

    Device with illuminated signage (8.46") (19.06") (1.97") 72/43* 848 (33.39") (2.83"/1.69"*) (1.38") 600 (23.62") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 26: Device With Illuminated Signage And Lower Light Case

    Device with illuminated signage and lower light case (8.46") (19.06") (1.97") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 27: Procash 2050Xe Usb With 6-Cassette Dispenser

    Planning the Installation Device dimensions (35 mm (1.38") tunnel) ProCash 2050xe USB with 6-cassette dispenser Device without illuminated signage (8.46") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max.
  • Page 28: Device With Illuminated Signage

    Device with illuminated signage (8.46") (19.06") (1.97") 72/43* 848 (33.39") 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 29: Device With Illuminated Signage And Lower Light Case

    Device with illuminated signage and lower light case (8.46") (19.06") (1.97") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (1.38") 1208 (47.56") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 30: Device Dimensions (60 Mm (2.36") Tunnel)

    Device dimensions (60 mm (2.36") tunnel) All dimensions are specified in millimeters (inches). The views of the device are not drawn to scale. All device edges have a radius of 3 mm (0.12"). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 31: Procash 2050Xe Usb With 4-Cassette Dispenser

    Planning the Installation Device dimensions (60 mm (2.36") tunnel) ProCash 2050xe USB with 4-cassette dispenser Device without illuminated signage (8.46") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (2.36") 1183 (46.57") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max.
  • Page 32: Device With Illuminated Signage

    Device with illuminated signage (8.46") (19.06") (2.95") 848 (33.39") 72/43* 600 (23.62") (2.83"/1.69"*) (2.36") 1183 (46.57") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 33: Procash 2050Xe Usb With 5-Cassette Dispenser

    Planning the Installation Device dimensions (60 mm (2.36") tunnel) ProCash 2050xe USB with 5-cassette dispenser Device without illuminated signage (8.46") 848 (33.39") 72/43* (2.36") (2.83"/1.69"*) (23.62") 1183 (46.57") 1243 (48.94") 13.5 (0.53") (19.69") (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max.
  • Page 34: Device With Illuminated Signage

    Device with illuminated signage (8.46") (19.06") (2.95") 848 (33.39") 72/43* (2.83"/1.69"*) (2.36") 1183 (46.57") 600 (23.62") 1243 (48.94") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 35: Procash 2050Xe Usb With 6-Cassette Dispenser

    Planning the Installation Device dimensions (60 mm (2.36") tunnel) ProCash 2050xe USB with 6-cassette dispenser Device without illuminated signage (8.46") (23.62") (2.36") 848 (33.39") 72/43* (2.83"/1.69"*) 1183 (46.57") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83")
  • Page 36: Device With Illuminated Signage

    Device with illuminated signage (8.46") (2.95") (19.06") 600 (23.62") 848 (33.39") 72/43* (2.36") (2.82"/1.69"*) 1183 (46.57") 13.5 (0.53") (19.69") 634 (24.96") * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 37: Installation Options

    Installation options Installation options The ProCash 2050xe USB can only be installed through a wall opening. The following table gives a list of installation options depending on the floor heights on the customer panel side and on the device side taking into account the ergonomical measurements.
  • Page 38: Device View (35 Mm (1.38") Tunnel)

    Installation options Planning the Installation Device view (35 mm (1.38") tunnel) Without illuminated signage ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 39: With Illuminated Signage

    Planning the Installation Installation options With illuminated signage 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 40: With Illuminated Signage And Lower Light Case

    Installation options Planning the Installation With illuminated signage and lower light case ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 41: Device View (60 Mm (2.36") Tunnel)

    Planning the Installation Installation options Device view (60 mm (2.36") tunnel) Without illuminated signage 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 42: With Illuminated Signage

    Installation options Planning the Installation With illuminated signage ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 43: Wall Cutout 4-Cassette And 5-Cassette Dispenser

    1 Outside wall 2 Inside wall (device side) W *: Wall thickness for 35 mm (1.38") tunnel: max. 360 mm (14.17") Wall thickness for 60 mm (2.36") tunnel: max. 335 mm (13.19") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 44: Wall Cutout 6-Cassette Dispenser

    1 Outside wall 2 Inside wall (device side) W *: Wall thickness for 35 mm (1.38") tunnel: max. 360 mm (14.17") Wall thickness for 60 mm (2.36") tunnel: max. 335 mm (13.19") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 45: Vents

    Make sure that the distance between the vents and the wall is always at least 50 mm (1.97") (see also section "Space required for operation and maintenance"). 1 Vents 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 46: Storage If Construction Work Is Not Yet Complete

    35 mm (1.38") tunnel and those with a 60 mm (2.36") tunnel. Ventilation area Additional operation and maintenance space, right or left Operation and maintenance space Additional space required for the installation (for reaching the fastening screws in the safe). 1 Wall ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 47 Planning the Installation Space required for operation and maintenance 35 mm (1.38") tunnel 1155 (45.47") (5.91") (15.94") (1.97") (1.97") 13.5 (0.53") 700 (27.56") (13.78") (13.78") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 48 Space required for operation and maintenance Planning the Installation 60 mm (2.36") tunnel 1155 (45.47") (15.94") (5.91") 13.5 (1.97") (1.97") (0.53") 700 (27.56") (13.78") (13.78") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 49: Installation Options

    ProCash 2050xe USB version with 60 mm (2.36") tunnel. Installation options 4-cassette dispenser The ProCash 2050xe USB can be installed through the wall with floors the same height on the inside and on the outside, with a higher floor on the outside or with a higher floor on the inside.
  • Page 50 8 25 mm (0.98") install. frame * Height of customer panel keypad W**: Wall thickness for 35 mm (1.38") tunnel: max. 360 mm (14.17") Wall thickness for 60 mm (2.36") tunnel: max. 335 mm (13.19") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 51 Planning the Installation Installation options Version I: The height-adjustable installation rack is needed if the ProCash 2050xe USB is to be installed on the floor and the inside and outside floor heights are different (see section "Height-adjustable installation rack"). Version II: The 222 mm (3.23") installation frame is needed if the...
  • Page 52: Installation Options 5-Cassette Dispenser

    Planning the Installation Installation options 5-cassette dispenser The ProCash 2050xe USB can be installed through the wall with floors the same height on the inside and on the outside, with a higher floor on the outside or with a higher floor on the inside.
  • Page 53 X5 Height of base (X5 base frame * Height of customer panel keypad W**: Wall thickness for 35 mm (1.38") tunnel: max. 360 mm (14.17") Wall thickness for 60 mm (2.36") tunnel: max. 335 mm (13.19") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 54 Not any difference in floor level can be compensated by the installation version described. Therefore, the following limit value applies for wall Version II: min. 813 mm (32.01") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 55: Installation Option 6-Cassette Dispenser

    Planning the Installation Installation options Installation option 6-cassette dispenser Standard installation of the ProCash 2050xe USB with the same floor height on the inside and the outside is with the 25 mm (0.98") installation frame. 1 Device 4 Floor outside 2 Wall 5 25 mm (0.98") installation frame...
  • Page 56: Installation Site Requirements

    (see section "Space required for operation and maintenance"). Load-carrying capacity Ensure that the installation site has the required load-carrying capacity. You will find the relevant device weight in the section "Installation specifications" in the chapter "Appendix". ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 57: Protection From Removal By Force In Compliance With En And Vds Guidelines

    CEN standard. In case of a mounting structure other than the one specified in the sections "Mounting the installation frame" or "Mounting the installation rack" in the chapter "Installation", always contact your insurance company beforehand. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 58: 25 Mm (0.98") Installation Frame

    The 25 mm (0.98") installation frame has to be used if you want to install the ProCash 2050xe USB (4- or 5-cassette dispenser) on a base (provided by customer) or if you want to install the ProCash 2050xe USB (6-cassette dispenser) on the floor.
  • Page 59: Dimensions Of Safe Attachment Points

    2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor 5 This side must always point to the side with the safe door. 6 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 60: Dimensions Of Cable Areas

    1 Cable lead-ins in the installation frame 2 Area for cables 3 Cable feed openings underneath the installation frame 4 This side must always point to the side with the safe door. 5 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 61: Calculating The Base Height

    25 mm (0.98") installation frame Calculating the base height If you want to set the ProCash 2050xe USB on a base, calculate the base height using the following formula (see also the illustration in the section "Installation options 4-cassette dispenser" or "Installation options 5-cassette dispenser"):...
  • Page 62: 82 Mm (3.23") Installation Frame

    General information The 82 mm (3.23") installation frame has to be used if you want to install the ProCash 2050xe USB (5-cassette dispenser) in the specified wall cutout and with the same floor height on both sides of the wall.
  • Page 63: Dimensions Of Safe Attachment Points

    2 Attachment points of installation frame 3 Attachment points of installation frame 4 Attachment point of tear-off sensor 5 This side must always point to the side with the safe door. 6 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 64: Dimensions Of Cable Areas

    1 Cable lead-ins in the installation frame 2 Area for cables 3 Cable feed openings underneath the installation frame 4 This side must always point to the side with the safe door. 5 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 65: 222 Mm (8.74") Installation Frame

    General information The 222 mm (8.74") installation frame has to be used if you want to install the ProCash 2050xe USB (4-cassette dispenser) in the specified wall cutout and with the same floor height on both sides of the wall.
  • Page 66: Securing The Installation Frame

    For a safe with resistance grade IV (CEN IV) it is mandatory that the CEN frame is secured at the points (2) and (3) with eight threaded rods (see illustration below). If the mounting set is not provided, use equivalent fastening material. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 67: Dimensions Of Safe Attachment Points

    UL / CEN L / CEN III safe 4 Attachment point of tear-off sensor 5 This side must always point to the side with the safe door. 6 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 68 2 Attachment points of installation frame 3 Alternative attachment points of UL safe 4 Attachment point of tear-off sensor 5 This side must always point to the side with the safe door. 6 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 69: Dimensions Of Cable Areas

    1 Cable lead-ins in the installation frame 2 Area for cables 3 Cable feed openings underneath the installation frame 4 This side must always point to the side with the safe door. 5 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 70 1 Cable lead-ins in the installation frame 2 Area for cables 3 Cable feed openings underneath the installation frame 4 This side must always point to the side with the safe door. 5 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 71: Height-Adjustable Installation Rack

    General information The height-adjustable installation rack (hereinafter referred to as installation rack) is needed if the ProCash 2050xe USB (4-cassette dispenser) is to be installed in existing wall cutouts and the inside and outside floor heights are different. It consists of a top and a bottom part.
  • Page 72: Securing The Installation Rack

    For a safe with resistance grade IV (CEN IV) it is mandatory that the CEN rack is secured at the points (1) and (2) with eight threaded rods (see illustration below). If the mounting set is not provided, use equivalent fastening material. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 73: Dimensions Of Safe Attachment Points

    UL / CEN L / CEN III safe 3 Attachment point of tear-off sensor 4 This side must always point to the side with the safe door. 5 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 74 594 (23.39") 539 (21.22") 179 (7.05") 1 Attachment points of safe 2 Hole for tear-off sensor 3 This side must always point to the side with the safe door. 4 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 75: Dimensions Of Cable Areas

    527 (20.75") 453 (17.83") 448 (17.64") 433 (17.05") 398 (15.67") 113 (4.45") 1 Area for cables 2 This side must always point to the side with the safe door. 3 Customer panel side 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 76 Top part 550 (21.65") 530 (20.87") 484 (19.06") 1 Cable feed openings into installation rack 2 This side must always point to the side with the safe door. 3 Customer panel side ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 77: Finding The Required Installation Rack

    93 mm (3.66") from 190 mm (7.48") 320 mm (12.6") 152 mm (5.98") from 320 mm (12.6") 530 mm (20.87") 270 mm (10.63") (UL, CEN L, CEN III) 480 mm (18.9") (CEN IV) 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 78 X1 Height of wall opening (X1 wall 2 Wall X2 Adjustable height (X2 height 3 Floor inside X3 Adjustable height of installation rack 4 Floor outside variable X4 Height of installation rack bottom part rack ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 79: Tear-Off Sensor

    No power or data cables may be installed underneath the CMD-V4. Drilling diagrams The following illustrations specify the distance from the edge (safe) of the drill holes that are used to secure the ProCash 2050xe USB with installation frame or installation racks. 01750058390 G...
  • Page 80: Drilling Diagram For 25 Mm (0.98") Installation Frame

    For the hole diameter please refer to the mounting instructions of the caulking cartridge. Hole for tear-off at least 40 mm (1.57") in concrete. sensor: Consult your alarm technician about the size of the hole and the cartridge. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 81: Drilling Diagram For 82 Mm (3.23") Installation Frame

    For the hole diameter please refer to the mounting instructions of the caulking cartridge. Hole for tear-off at least 40 mm (1.57") in concrete. sensor: Consult your alarm technician about the size of the hole and the cartridge. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 82: Drilling Diagram For 222 Mm (8.74") Install. Frame

    For the hole diameter please refer to the mounting instructions of the caulking cartridge. Hole for tear-off at least 40 mm (1.57") in concrete. sensor: Consult your alarm technician about the size of the hole and the cartridge. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 83: Safe Width 450 Mm (17.72")

    For the hole diameter please refer to the mounting instructions of the caulking cartridge. Hole for tear-off at least 40 mm (1.57") in concrete. sensor: Consult your alarm technician about the size of the hole and the cartridge. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 84: Drilling Diagram For Height-Adjustable Installation Racks

    For the hole diameter please refer to the mounting instructions of the caulking cartridge. Hole for tear-off at least 40 mm (1.57") in concrete. sensor: Consult your alarm technician about the size of the hole and the cartridge. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 85: Power And Data Cables

    Avoid excess lengths of cable by shortening them where necessary. You must ensure that connecting cables do not impede or actually damage any moving components. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 86 You will also find details of the position of cable routing for the device in the sections "25 mm (0.98") installation frame", "82 mm (3.23") installation frame, "222 mm (8.74") installation frame" or "Height- adjustable installation rack". ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 87: Power Supply

    L N PE 1 Fuse or automatic circuit-breaker 2 Connection for ProCash 2050xe USB (incl. optional heater) 3 Modem connection 4 Connection of miscellaneous equipment Remote status indicator The optional remote status indicator comes with a 50 m (164.1 ft) connecting...
  • Page 88: Dimensions Of Illuminated Logos

    Dimensions of illuminated logos Planning the Installation Dimensions of illuminated logos If the ProCash 2050xe USB was ordered without logos, the logos have to be provided by the customer. The illustration shows the visible outer surface of the upper logo case (454 mm x 165 mm (17.87"...
  • Page 89: Transport Path Requirements

    Observe the ambient condition requirements for transportation and storage (see chapter "Appendix", section "Technical data"). Due to the shipping crate some dimensions are different (see illustrations below). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 90: Transport Measurements For Procash 2050Xe Usb

    Transport path requirements Planning the Installation Transport measurements for ProCash 2050xe ProCash 2050xe USB with 4-cassette dispenser Safe width 600 mm (23.62") 72/43* 848 (33.39") 580 (22.83") (2.83"/1.69"*) 1208 (47.56") 690 (27.17") 1 Shipping crate * Standard lock: 43 mm (1.69") Customer-specific lock: max.
  • Page 91 Planning the Installation Transport path requirements Safe width 450 mm (17.72") 738 (29.06") 606 (23.86") (4.33") 1098 (43.23") 670 (26.38") 1 Shipping crate 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 92: Procash 2050Xe Usb With 5-Cassette Dispenser

    Transport path requirements Planning the Installation ProCash 2050xe USB with 5-cassette dispenser 580 (22.83") 848 (33.39") 72/43* 690 (27.17") (2.83"/1.69"*) 1208 (47.56") 1 Shipping crate * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") ProCash 2050xe USB - Installation Guide...
  • Page 93: Procash 2050Xe Usb With 6-Cassette Dispenser

    Planning the Installation Transport path requirements ProCash 2050xe USB with 6-cassette dispenser 848 (33.39") 580 (22.83") 1208 (47.56") 72/43* 690 (27.17") (2.83"/1.69"*) 1 Shipping crate * Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 94 Refer to the next page for an example. Safe width 600 mm (23.62") 1350 (53.15") 1580 (62.2") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 95 Planning the Installation Transport path requirements Safe width 450 mm (17.72") 1350 (53.15") 1580 (62.20") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 96: Example With Minimum Transport Path Measurements

    Transport path requirements Planning the Installation Example with minimum transport path measurements Safe width 600 mm (23.62") 710 (27.95") 1350 (53.15") 1580 (62.2") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 97 Planning the Installation Transport path requirements Safe width 450 mm (17.72") 730 (28.74") 1350 (53.15") 1580 (62.2") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 98 Transport path requirements Planning the Installation ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 99: Installation

    Make sure that the values are neither higher nor lower than the specified values to prevent irreparable damage to the device. WINCOR NIXDORF International GmbH is not liable for any damage to the device resulting from failure to meet these conditions.
  • Page 100: Removing The Shipping Crate

    For transportation the device is equipped with a shipping crate. This must be removed before installation. To move the device, only push against the sides of the safe as shown in the following illustration. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 101: Removing The Shipping Crate

    Lift the device. Remove the shipping crate of the ProCash 2050xe USB (1). • Dispose of the shipping crate which is no longer needed according to the regulations of your country. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 102: Mounting Sets

    Mounting sets Installation Mounting sets The mounting sets are supplied with the installation frame or installation rack of the ProCash 2050xe USB. The mounting set for the tear-off sensor is not supplied with the device. Mounting set 01750006706 for installation frames or installation racks with UL safe If the mounting set is not provided, use equivalent fastening material.
  • Page 103: Mounting Set 01750051579 For Installation Frames Or Installation Racks With Cen Iii/Iv Safe

    * For a CEN IV safe two mounting sets are supplied with the 82 mm (3.23"), 222 mm (8.74") installation frame and the installation rack. For mounting the 25 mm (0.98") installation frame, only one mounting set is necessary. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 104: Mounting Set 01750078516 (For Ul / Cen L Safe) On 25 Mm (0.98") Installation Frame

    (3.23") and 222 mm (8.74") installation frames or height-adjustable installation racks Item Quantity required Pan head screw M16 x 60 – (ISO 4762, property class 10.9) Washer A 17 ISO 7089-St – ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 105: Overview Of Installation Types

    (see p. 124) * If you want to use a height-adjustable installation rack and the floor height inside and outside is the same, the ProCash 2050xe USB can also be installed on the 190 to 320 mm (7.48" to 12.6") installation rack.
  • Page 106: Installation With 25 Mm (0.98") Installation Frame

    If the mounting set is not provided, use equivalent fastening material. The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with a total of four threaded rods. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 107 P * Pos. of instal. frame for 35 mm (1.38") tunnel: 368 ± 5 mm (14.5" ± 0.2") Position of the installation frame for 60 mm (2.36") tunnel: 343 ± 5 mm (13.5" ± 0.2") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 108 The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustrations below). Consult your alarm technician about the size of the hole and the fixing. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 109 125 mm (4.92") in the load- bearing concrete. Excess lengths must be shortened correspondingly or, if necessary in case of deeper floor anchorages, be replaced by equivalent threaded rods. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 110 The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98"). • Insert the fixing for the tear-off sensor if required. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 111 Screw the installation frame to the base (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material. The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 112: Mounting The Device On The Installation Frame

    When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 113: Screwing The Device On The Installation Frame

    (2) in the illustration). Screw the safe to the installation frame (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 114: Pushing The Cash Media Dispenser (Cmd-V4) Down

    Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. • Replace the filling piece of the installation frame (position 5b) and the filling piece of the safe. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 115: Further Procedure For Cen Installation

    The locking axle and the track stops must remain in the safe for later service operations. If the tunnel frame is to be installed immediately afterwards, release the customer panel (see section "Installing the tunnel frame"). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 116: Installation With 82 Mm (3.23") Installation Frame

    Installation Installation with 82 mm (3.23") installation frame The following description refers to an installation of the ProCash 2050xe USB with 5-cassette dispenser with the same floor height. Mounting the installation frame Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation",...
  • Page 117 P * Position of the installation frame for 35 mm (1.38") tunnel: 368 ± 5 mm (14.49" ± 0.2") Pos. of instal. frame for 60 mm (2.36") tun.: 343 ± 5 mm (13.5" ± 0.2") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 118 The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 119 Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge. The threaded rods must protrude at a minimum 33 mm (1.3") and at a maximum 50 mm (1.97"). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 120 Screw the installation frame to the base (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material. The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 121: Mounting The Device On The Installation Frame

    When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 122: Screwing The Device On The Installation Frame

    (2) in the illustration). Screw the safe to the installation frame (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 123: Pushing The Cash Media Dispenser (Cmd-V4) Down

    Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. • Replace the filling piece of the installation frame (position 5b) and the filling piece of the safe. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 124: Further Procedure For Cen Installation

    The locking axle and the track stops must remain in the safe for later service operations. If the tunnel frame is to be installed immediately afterwards, release the customer panel (see section "Installing the tunnel frame"). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 125: Installation With 222 Mm (8.74") Installation Frame

    Installation with 222 mm (8.74") installation frame Installation with 222 mm (8.74") installation frame The following description refers to the installation of the ProCash 2050xe USB with 4-cassette dispenser with the same floor height. Mounting the installation frame Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation",...
  • Page 126 UL / CEN L / CEN III safe) or two threaded rods (for CEN IV safe) per group of holes A to D (see illustration below). The installation frame is secured with a total of four or eight threaded rods. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 127: Safe Width 600 Mm (23.62")

    Wall thickness for 60 mm (2.36") tunnel: max. 335 mm (13.19") P * Position of the installation frame for 35 mm (1.38") tunnel: 368 ± 5 mm (14.49"±0.2") Pos.of install.frame for 60 mm (2.36") tun.: 343 ± 5 mm (13.5" ± 0.2") 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 128: Safe Width 450 Mm (17.72")

    P * Position of the installation frame for 35 mm (1.38") tunnel: 368 ± 5 mm (14.49" ± 0.2") Pos.of install.frame for 60 mm (2.36") tun.: 343 ± 5 mm (13.5" ± 0.2") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 129: General Information

    The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 130 125 mm (4.92") in the load- bearing concrete. Excess lengths must be shortened correspondingly or, if necessary in case of deeper floor anchorages, be replaced by equivalent threaded rods. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 131 • Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 132: Mounting The Device On The Installation Frame

    When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 133: Screwing The Device On The Installation Frame

    (2) in the illustration). Screw the safe to the installation frame (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 134: Pushing The Cash Media Dispenser (Cmd-V4) Down

    Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. • Replace the filling piece of the installation frame (position 5b) and the filling piece of the safe. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 135: Further Procedure For Cen Installation

    The locking axle and the track stops must remain in the safe for later service operations. If the tunnel frame is to be installed immediately afterwards, release the customer panel (see section "Installing the tunnel frame"). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 136: Installation With Height-Adjustable Installation Rack

    Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (67 mm (2.64") in relation to the bottom part of the installation rack). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 137: Preparing The Installation Rack

    Height of wall opening (X1 wall 2 Wall X2 Adjustable height (X2 height 3 Floor inside X3 Adjustable height of installation rack 4 Floor outside variable X4 Height of installation rack bottom part rack 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 138: Calculation Of Rack Height

    93 mm (3.66") from 190 mm (7.48") 320 mm (12.6") 152 mm (5.98") from 320 mm (12.6") 530 mm (20.87") 270 mm (10.63") (UL, CEN L, CEN III) 480 mm (18.9") (CEN IV) ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 139: Mounting The Installation Rack

    (for UL / CEN L / CEN III safe) or two threaded rods (for CEN IV safe) per group of holes A to D. The installation rack is secured with a total of four or eight threaded rods. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 140 P * Position of the installation frame for 35 mm (1.38") tunnel: 382 ± 5 mm (15.04" ± 0.2") Position of the installation frame for 60 mm (2.36") tunnel: 357 ± 5 mm (14.06" ± 0.2") ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 141 Drill the required four or eight holes (1) and the hole for the tear-off sensor, if necessary (2). Clean the bore holes as specified in the mounting instructions of the caulking cartridge. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 142 The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 143 125 mm (4.92") in the load- bearing concrete. Excess lengths must be shortened correspondingly or, if necessary in case of deeper floor anchorages, be replaced by equivalent threaded rods. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 144 4x CEN III installation rack to the floor (for 8x CEN IV material see section "Mounting sets"). If applicable, note the hardening times of the mounting material. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 145: Installing The Top Part Of The Installation Rack

    Place the top part of the installation rack on the floor as shown in the following illustration. Screw the four hexagon nuts onto the threaded rods as far as the calculated measurement X3 (X3) (1). variable 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 146 The distance from top edge of the top part to the lower edge of the hole in the wall has to be 648 mm (25.51"). Make sure that the top part of the installation rack is horizontal. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 147 Use spacers and nuts to retain the height that you have set. To do this, place the spacers and nuts on the threaded rods in the bottom part of the installation rack. Tighten the four nuts (see illustration below). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 148 (7) of the installation rack, as in the example shown here. Make sure that the connecting cables are laid in such a way that they are not pinched or squished by the installation rack. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 149: Mounting The Device On The Installation Rack

    (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 150: Screwing The Device On The Installation Rack

    (see attachment points (1) and (2) in the illustration). Screw the safe to the installation rack (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 151: Pushing The Cash Media Dispenser (Cmd-V4) Down

    Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation rack. • Replace the filling piece of the installation rack (position 1) and the filling piece of the safe, if applicable. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 152: Further Procedure For Cen Installation

    The locking axle and the track stops must remain in the safe for later service operations. If the tunnel frame is to be installed immediately afterwards, release the customer panel (see section "Installing the tunnel frame"). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 153: Installing The Tunnel Frame

    Installation is to the greatest extent the same for a tunnel frame with and without illumination. Any differences that exist are described here explicitly. The illustrations show the device with illumination. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 154: Pulling Out/Pushing In The Customer Panel

    Open the operating unit door (see chapter "Basic Operation" in the operating manual). • Push the two release levers of the customer panel down (1). Pull the customer panel forward out of the device as far as possible (2). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 155 Pushing it in Loosen the securing screw until it no longer sits in the lower groove of the track. Then push the customer panel into the device until the release levers click into place. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 156: Installing The Sealing Frame

    Push the sealing frame over the customer panel (1) into the wall opening until it touches the outer wall all around. • Attach the sealing frame to the device at the five attachment points (2) (right, left, top (2x) and bottom). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 157 Installing the tunnel frame Seal the sealing frame with silicone along the sides and along the top edge (3). Do not seal the sealing frame on the bottom! (Silicone is not included in the shipment!) 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 158: Installing The Adjusting Plates

    Loosen the securing screw of the customer panel until it no longer sits in the lower groove of the track (see section "Pulling out/pushing in the customer panel"). • Then push the customer panel into the device until the release levers click into place. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 159 Unlock the operating unit, pull it out as far as possible and secure the customer panel with a screw so that it cannot accidentally close/bang shut (see section "Pulling out/pushing in the customer panel"). • Secure each adjusting bolt with a corresponding nut. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 160: Securing The Tunnel Frame

    First push the tunnel frame on the operating unit at the bottom (1) and then at the top (2). Be careful not to crush the cable (3). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 161 Tighten the four nuts at the top of the tunnel frame (1). • Attach the tunnel frame to the adjusting plates on the left (2) and on the right (3) using two nuts on each side. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 162: Connecting The Logo Light (Only On Tunnel Frames With Illuminated Signage)

    Installing the tunnel frame Installation Connecting the logo light (only on tunnel frames with illuminated signage) Disconnect the cable from the retaining aluminum bracket (1). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 163 Press the illumination unit back into the retaining clips. Lay the cables in such a way that they will not be damaged when the customer panel is pulled out or pushed in. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 164: Connecting The Tunnel Frame Light

    Loosen the securing screw until it no longer sits in the lower groove of the track (see section "Pulling out/pushing in the customer panel"). • Then push the customer panel into the device until the release levers click into place. • Close the device. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 165: Start-Up

    Installation Start-up Start-up The service technician will connect the power and data cables. No power or data cables may be installed underneath the CMD-V4. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 166 Start-up Installation ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 167: Installing The Remote Status Indicator

    (3.98" x 1.8" x 1.06") (W x H x D)) Phillips screws SPAX 2.5 x 20 (countersunk head) Fixings Ø 4 mm (0.16") The enclosed mounting material is used to secure the indicator to masonry or wooden paneling. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 168: Installation

    Drill the necessary bores: drill depth: 20 mm (0.79"), drill diameter: 4 mm (0.16"), and insert the enclosed fixings in the holes. Secure the lower section to the wall with the enclosed screws and press the front cover onto the lower section. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 169: Connection To The Relay Panel For External Features

    Marking on wires The wires are marked with an adhesive label at the end as follows: - 11 RED LIGHT WHITE - 12 YELLOW LIGHT GREEN - 13 GREEN LIGHT BLACK - 14 GND 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 170 Connect the individual wires to the relay panel for external features as follows: 11 121314 Name Wire 'RED - 11 RED LIGHT' Wire 'WHITE - 12 YELLOW LIGHT' Wire 'GREEN - 13 GREEN LIGHT' Wire 'BLACK - 14 GND' • Close the device. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 171: Remote Status Indicator - Audio

    (4.65" x 3.8" x 1.59") (W x H x D)) Phillips screws SPAX 4 x 40 (half-round screws) Fixings Ø 6 mm (0.24") The enclosed mounting material is used to secure the indicator to masonry or wooden paneling. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 172: Installation

    (energy, media line, etc.). Position the back panel and mark the points where it is to be secured. Allow sufficient space to install the connecting cable on the right (approx. 20 mm (0.79")). ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 173 Remove the required label (1) and apply it to the space provided (2) on the audio remote status indicator. • Lay the connecting cable of the audio Remote Status Indicator to the appropriate device. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 174: Connection To The Relay Panel For External Features

    Marking on wires The wires are marked with an adhesive label at the end as follows: - 11 RED LIGHT WHITE - 12 YELLOW LIGHT GREEN - 13 GREEN LIGHT BLACK - 14 GND ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 175 Connect the individual wires to the relay panel for external features as follows: 11 121314 Name Wire 'RED - 11 RED LIGHT' Wire 'WHITE - 12 YELLOW LIGHT' Wire 'GREEN - 13 GREEN LIGHT' Wire 'BLACK - 14 GND' • Close the device. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 176: Shortening The Cables

    Use a screwdriver to press carefully through openings (1) and (2) until the tabs behind them disengage. Remove the front cover (3) forwards. Release the four terminals of the terminal strip (1) and remove the front cover. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 177 Marking on wires The wires are marked with an adhesive label at the end as follows: - RED LIGHT WHITE - YELLOW LIGHT GREEN - GREEN LIGHT BLACK - GND 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 178 Wire 'WHITE - YELLOW LIGHT' Wire 'GREEN - GREEN LIGHT' Wire 'BLACK - GND' • Press the front cover onto the lower section. Ensure that no wires are damaged in the process. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 179: Adapting The Cable Length At The Remote Status Indicator (Audio)

    Loosen screw (1). Move the back panel (2) to one side at the bottom and pull the panel downwards out of the front cover. Remove the two screws (1) and move the board (2) to one side. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 180 Shorten the cable end as shown in the following diagram. You must strip approx. 25 mm (0.98") of the cable insulation and 4.5 mm (0.98") (0.18") of the individual wire insulation. The individual wire ends must be (0.18") twisted. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 181 Wire 'GREEN - GREEN LIGHT' Wire 'BLACK - GND' • Press the connecting cable with the spacer into the cable guide (2). • Mount the board and the back panel as described above under removal. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 182 Shortening the cables Installing the Remote Status Indicator ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 183: Appendix

    After checking off all items, copy this list, send it to your head of operations and make arrangements for an installation date. Name: Telephone number: Fax number: 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 184: General Information

    Is the securing of cash-dispensers in the raw concrete ensured (CEN standard)? Is the frame aligned and fastened in accordance with the installation instructions? Has a wall cutout that may be required been completed? Are the ambient conditions met? ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 185: Power And Data Cables

    Have you discussed the diameter of the hole that is to be drilled and the fixing to be used for the tear-off sensor with the local alarm provider? Diameter? Fixing to be used? 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 186: Delivery And Installation

    Carpet Raised floor Marble floor Tiles Others Please enter the width of the most narrow door Please enter the width of the most narrow hallway Checked by customer: Checked by installation technician: ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 187: Notes Concerning Installation Preparation

    Appendix Check list for installation preparations for self-service systems Notes concerning installation preparation 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 188 Check list for installation preparations for self-service systems Appendix ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 189: Technical Data

    (network with PE (network with PE conductor) conductor) Permissible tolerance for voltage range: -10 % to +6 % -10 % to +6 % Permissible tolerance for rated frequency: ±1 % ±1 % 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 190: Device Conditions

    290 VA 455 VA 280 VA 410 VA Active power: 265 W 395 W 245 W 370 W Power factor: Leakage current (max.): 3.5 mA 3.5 mA 3.5 mA 3.5 mA ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 191 Degree of protection in acc. with EN 60529: Outdoors: IP 54 IP 54 Indoors: IP 20 IP 20 * If a UPS is used, it must be connected with a CEE plug only. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 192: Installation Specifications

    (450 mm (17.72")): (1351.4 UL safe (600 mm (23.62")): (1631.4 (1774.7 CEN L safe: (1300.7 CEN III safe: (2017.2 CEN III / CNPP safe: 1010 (2226.7 CEN IV safe: 1015 (2017.2 (2237.7 ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 193 (2.89 lbf/in²) (3.2 lbf/in²) Fan capacity: m³/h m³/h m³/h (2118.6 ft³/h) (2118.6 ft³/h) (2118.6 ft³/h) Detailed information concerning the dimensions is provided in the chapter "Planning the Installation", section "Device dimensions". 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 194: Environmental Conditions

    All types of commercial vehicles and trailers original packing) as well as rail and air transport Storage (in original Noticeable vibration and bumps caused for packing) example by machines or passing vehicles ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 195 They must comply with the environmental conditions that apply to the specific device (see above) and the maintenance areas (see chapter "Planning the Installation", section "Space required for operation and maintenance"). 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 196: Compliance With Standards And Certification

    The CE mark of conformity attached to the product or its package indicates that the product complies with the requirements of the following EC directives: − EMC Directive 2004/108/EC − Low Voltage Directive 2006/95/EC The corresponding statement of compliance has been issued by: ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 197: Notes Concerning Radio Interference Suppression And Electrical Safety

    Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 198: Ul 291, Level 1 (Security Container)

    This means that crucial criteria such as long life, choice of material and its labeling, emissions, packaging, ease of disassembly and recyclability have been taken into account. This saves resources and relieves the strain on the environment. ProCash 2050xe USB - Installation Guide 01750058390 G...
  • Page 199: Saving Energy

    Environmental Protection section (Referat Umweltschutz): Tel.: +49 (0) 52 51 693 67 07 Fax.: +49 (0) 52 51 693 77 67 07 E-mail: referat.umweltschutz@wincor-nixdorf.com 01750058390 G ProCash 2050xe USB - Installation Guide...
  • Page 200 Environmental protection Appendix ProCash 2050xe USB - Installation Guide 01750058390 G...