NOTE: The 12 Volt DC supply output from the speaker unit is current-limited and has independent reservoir and filter components. It is intended to supply one microphone only. DO NOT ATTEMPT TO USE THIS OUTPUT FOR ANY OTHER PURPOSE! DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007...
This cable does not require a screen and should ideally be of a 1.0mm cross-section. NOTE:- The 12 Volt DC power cable should be kept as short as possible and, in any event, no longer than 10 metres. DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007 Page 3 of 8...
Page 4
AUXILIARY THROUGH (COLD) IN (From Microphone) +VIN 12V DC POSITIVE SUPPLY INPUT 12V DC 0V SUPPLY INPUT (COMMON 0V) LSP+ TO LOUDSPEAKER (HOT) (FACTORY PRE-WIRED) LSP- TO LOUDSPEAKER (COLD) (FACTORY PRE-WIRED) DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007 Page 4 of 8...
PCBs H & C (balanced) input terminals, they cancel each other out! So, if you have installed the system, and you have no audio, check that you have followed these instructions! DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007 Page 5 of 8...
Page 6
Microphone Head Cable Screen J3 (O/P H) Audio Input (H) at monitoring device J3 (O/P C) Audio Input (C) at monitoring device J3 Pin 3 Screen connection at monitoring device DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007 Page 6 of 8...
Page 7
“+V OUT” and “0V OUT” and connect the power input terminals of the microphone pre-amp module to the DC output of the linear power adapter supplied in the kit. IMPORTANT ! SEE NOTE #1 ON PAGE 5 FOR PC CARD SOURCES DOCUMENT NUMBER AVS/CSGAMKIT01/OEM/01 REV 1.2 28th November 2007...
Page 8
TECHNICAL SUPPORT Advanced Visual Solutions Ltd provide full technical support for our products. We have two, fully equipped “central station” workstations, running the latest version of ADPRO video central gold software and HEITEL monitoring software.