Thank you for purchasing the Myron L
simple to use in diverse water quality applications. Advanced features include; automatic temperature compensation from 15
calibration mode; highly stable microprocessor-based circuitry; waterproof Ultrapen™ housing, and nobile device GUI application that is user
intuitive. The PTBT3 is easy to calibrate and easy to use.
I. DOWNLOADING THE MOBILE DEVICE APP
1. Go to the Apple App Store.
2. Search for the "Ultrapen PTBTx" iPhone App.
3. Open the Ultrapen page and tap the Install button.
4. Be sure to read the End User License Agreement (EULA) and the Data Use Liability Agreement (DULA).
II. OPENING THE ULTRAPEN APP
1. Go to the Apple App Store. And search for the "Ultrapen PTBTx" iPhone App.
2. Tap Ultrapen App icon on the mobile device's HOME screen.
3. The App's main Measurement screen will appear.
I. PTBT3
1. PUSH BUTTON – Turns PTBT3 ON. Used to put the PTBT3 into Calibration
or Settings modes when prompted by App.
2. BATTERY CAP – Unscrew to access battery for replacement.
3. POCKET CLIP – Holds PTBT3 to shirt pocket for secure storage.
4. WIRELESS TRANSCEIVER WINDOW – Bluetooth antenna is located here.
5. LED INDICATOR LIGHT – Tells the user when to dip & swirl PTBT3 during
measurements and calibration. Indicates PTBT3 is in Configuration mode.
6. ORP SENSOR – Measures oxidation-reduction potential or redox of solution.
7. SOAKER CAP – Contains ORP sensor storage solution to maintain sensor
hydration. To remove, twist the cap while pulling off. Use caution not to spill
solution. To replace, fill the cap with storage solution half full ONLY. Twist the cap while pushing on. Be careful, excess solution may squirt
out.
8. CAP STOP – DO NOT push the protective cap beyond the cap stop as sensor damage could occur.
9. SCOOP – Used to hold sample solution when dipping is not possible. To use, push the scoop onto the sensor while shifting side-to-side and
hold the scoop directly under a vertical stream, avoiding bubbles. To remove, pull the scoop off while shifting side-to-side. If the sensor is
not fully seated in the PTBT3, reinstall per ORP sensor replacement instructions in the Maintenance section of this document.
10. ORP ELECTRODE CLEANING PAPER – Used for deep cleaning the platinum electrode.
11. LANYARD and HOLSTER: Not shown.
II. ULTRAPEN APP MEASUREMENT SCREEN
1. MOBILE DEVICE STATUS BAR – Standard status bar for your mobile device.
2. MEASUREMENT VALUE FIELD – Displays the measured value of the solution. When the PTBT3 turns
OFF, displays the message, "Ultrapen is Offline" and values gray out.
3. UNITS OF MEASURE – Displays ORP units of measure (mV).
4. PTBT3 BATTERY LEVEL – Flashes RED when PTBT3 battery is ≤ 25%.
5. SOLUTION TEMPERATURE – Measured temperature of the solution.
6. MEMORY STORE BUTTON – Tap here to record the measurement in the App's database.
7. MEMORY REPLACE BUTTON – Tap here to replace a previously stored measurement with data from a
new measurement.
8. FEATURE NAVIGATION BAR – These buttons activate various App features.
TO ACCESS A FULL OPERATION MANUAL:
1. Inside the App tap the Preferences button on the Feature Navigation Bar.
2. Select Help from the Settings Menu screen.
3. The browser of your mobile devices will open and link to the Myron L
Manual can be accessed by selecting PTBTxOM.
The following are basic instructions for operating the PTBT3 & App.
I. CONNECTING THE ULTRAPEN TO THE MOBILE DEVICE
To pair to and connect a PTBT3 to your mobile device:
1. Inside the App tap the Connect button in the Feature Navigation Bar.
2. Press and release the push button on the PTBT3 to turn it ON.
3. When the PTBT3's name appears on the Connect screen, select that line.
4. A checkmark will appear next to PTBT3's name.
NOTE: The default name for all PTBT3's is, "MLC-PTBTx". To edit the name, Tap the Preferences button and go to PTBT3
Settings section (See the PTBTx App Operation Manual for full instructions).
To unpair from a PTBT3:
1. Tap the red Unpair button next to the PTBT3's name.
2. An Unpair Instrument dialogue box will appear.
3. Tap the Disconnect button in the dialogue box.
PTBT3OM 05-15
ULTRAPEN™ PTBT3 Operation Manual
ORP and Temperature Pen for Use with your Mobile Device
INTRODUCTION
®
Company Ultrapen™ PTBT3 ORP Pen. This instrument is designed to be extremely accurate, fast and
FEATURES
OPERATION INSTRUCTIONS
®
Company website page where the PTBTx Operation
o
C to 30
o
C while in
1
Need help?
Do you have a question about the ULTRAPEN PTBT3 and is the answer not in the manual?
Questions and answers