The Technical Specifications of the Tests performed by the SmartPAT 5500 Portable Appliance Tester are
as follows:
Earth Bond
The earth bonding specifications are taken at a nominal mains input supply of 110 V or 235 V rms, unless
otherwise stated.
High Current
Open Circuit Voltage
Test Current
Display Resolution
Display Accuracy
Test Duration
Business Equipment
Open Circuit Voltage
Test Current
Display Resolution
Display Accuracy
Test Duration
Pass Threshold
Insulation Test
The earth bonding specifications are taken at a nominal mains input supply of 110 V or 235 V rms, unless
otherwise stated.
Open Circuit Voltage
Short Circuit Current
Current into 500k
Display Resolution
Display Accuracy
Test Duration
Pass Threshold
Fuse/Load/Leakage Test
Leak
Earth Leakage Current
Display resolution
Display accuracy
Leakage threshold
Abort on leakage
4
3 V rms ±10%
5 A, 8 A or 26 A ±15% into 0.1 ohm load.
(in-built intelligent current limit)
0.01 ohm to 19.99 ohm, then shows >20 ohm.
±(3% + 4 digits)
10s or 15s to 1 minute, dependent on time test button held down
3 V rms ±10%
100 mA +20% -0% at 230 Vrms into 0.5 ohm load.
0.01 ohm to 19.99 ohm, then shows >20 ohm.
±(3% + 4 digits)
10s or 15s to 1 minute, dependent on time test button held down
0.1 ohm steps up to 5 ohm then 0.5 ohm steps to 19.99 ohm
(user selectable)
560 V dc +16%, -0%
3.5 mA ±10%
1.0 mA minimum
0 1 to 99.9 Mohm, then 1 to 299 Mohm, >300 Mohm
±(5% + 4 digits)
10s or 15s to 1 minute, dependent on time test button held down
0.1 Mohm steps to 0.9 Mohm
1 Mohm steps from 1 to 9 Mohm
10 Mohm steps from 10 to 300 Mohm
(user selectable)
0.1mA to 9.9mA
0.1mA
±(5% + 4 digits), capacitive/resistive leakage
0.5 to 10 mA in 0.5 mA steps
> 15 mA