Pump Test and Installation

Before you install the pump in the system, set the direction of
pump rotation and the position of the pressure rollers:
1. Remove front cover from pump (four screws).
2. See Figure 1. For easier adjustment, check that pressure
rollers are in position shown (one roller compressing middle
of hose, and one roller free).
Note: Model 2006 and 2007 pumps use a different rotor
assembly than the one shown.
W0455
3. Connect incoming power supply to motor (refer to motor
manufacturer's instructions).
4. See Figure 2. Run pump and check direction of rotation,
"A" or "B" as shown. All pumps must rotate in direction "A"
(counterclockwise). To reverse rotation, exchange two of
three wires that connect incoming power to motor.
DISCHARGE
W0456
INLET
W0456
5. Set pressure rollers (see "Service: Setting the Roller
Pressure"). Roller pressure is not set at factory, because it
must be adjusted to compensate for size of inlet and discharge
lines and specific gravity of fluid being pumped.
6. Verify all fasteners are properly tightened.
7. Reattach front cover.
8. Install pump in system.
Wanner Engineering, Inc.
Pressure
Rollers
Figure 1
Figure 2

Before Initial Start-Up

Before you pump fluid through the system, be sure that:
1. All shutoff valves are open.
2. All connections are tightly secured.
3. See Hose Identification Table. Hose material is compatible
with fluid being pumped, and hose design matches duty cycle
and discharge pressures.
Hose Identification
Extruded
Code
Hypalon
HE
Neoprene
PE
Varprene
VE
Silicone
SE
Pharmed
FE
®
Fiber Braided
Hypalon
HF
EPDM
EF
Natural Rubber
NF
Natural Rubber
MF
Nitrile Rubber
BF
Nitrile Rubber - Oil Rated
OF
4. See Material Operating Temperatures Table. Temperature of
fluid pumped is within operating temperature range of hose
material installed in pump. Hose material can be identified by
5
and 6
digit of pump model number. E.g. 2007-NF-BB-D2,
th
th
where 'NF' designates natural rubber.
CAUTION: Contact factory when pumping a fluid that is
within 15˚ F of the maximum hose temperature. Take safety
precautions to insure hot pumpage does not harm operators
if a hose leaks.
Material Operating Temperatures
Material
EPDM
Hypalon
Neoprene
Silicone
Varprene
Natural Rubber
Nitrile Rubber
Pharmed
®
United States
Instant Information: www.vectorpump.com
(61) 33-5681 Fax (61) 33-6937
Description
Black color, shinny smooth surface
Flat black color, rough surface, rubber
smell
Cream color, smooth surface
Rust color, smooth surface
Cream color, Pharmed
name on hose
®
Black color, yellow stripe, double
braided
Black color, white stripe, double braided
Black color, green stripe, double
braided (standard duty)
Black color, no stripes, thick double
braids (heavy duty)
Black color, white inner hose
Black color, HBRF-HY-K stamped on
hose
Operating Temperatures
0 to 180˚ F
0 to 180˚ F
50 to 130˚ F
0 to 180˚ F
0 to 160˚ F
0 to 185˚ F
0 to 160˚ F
0 to 180˚ F
VEC-991-400A