Page 1
FRED SR | SR2 | SR1 C | SR2 C FRED SR FRED SR2 FRED SR1 C FRED SR2 C READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www.diversitech.ca 1200 55 Avenue, Montreal, Quebec H8T 3J8 Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca...
SECTION 1 - SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION This manual contains specific cautionary statements related to worker safety. To protect yourself and READ others, read this manual thoroughly and follow as directed before use. Not all hazards of fume & dust BEFORE control are listed in this manual, and no hazards related to welding, cutting, grinding, painting, deburring or other applications are listed.
Never use or install equipment where the potential for combustible fumes or dusts are present without a fire/explosion protection system. • If you are unsure if the product you purchased is correct for your application, call Diversitech at 1-800-361-3733. 1.5 Safety Stickers •...
3.4 Mounting Options • If you purchased a mobile model, see APPENDIX 3: Installation of Fred SR/SR2. If you purchased a wall/ceiling mounted model, see APPENDIX 6: Installation of Fred SR2 C/SR1 C. • 3.5 Electrical Options Single-Phase Unit: See APPENDIX 1A: Electrical Diagram [120 VAC] Single-Phase Power for wiring •...
• Do not use product without first confirming if a Spark Arrestor is required and installed for the type of dust, or fumes you are extracting and/or collection. If you are unsure, call a Diversitech representative at 1-800-361-3733. 4.2 Controls •...
4.4 Principles of Operation This product is designed to capture and clean smoke and dust from medium & heavy duty welding, soldering, and grinding applications. When operating, air is drawn in to the nozzle, passes through the 7” diameter hose, then through the air cleaner’s filtration system, and is exhausted through the rear discharge.
SECTION 5 - MAINTENANCE & TROUBLESHOOTING 5.1 To Maintain this Product Safely • Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. • Do not breathe the dust collected from product while changing/cleaning filters or performing maintenance on this product.
5.3 Routine Maintenance Schedule The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the unit is used in severe conditions. Frecuency Manual Reference Pre-Use • Perform pre-use inspection to ensure operating correctly. ISC-360 Self-Cleaning Cycle •...
5.4 Troubleshooting Procedure Turn Unit Call for Service Check Leads at Motor 1(800)361-3733 INTERMITTENTLY Input Power Operating support@diversitech.ca Source Motor Air Flow Operating Restricted Check/clean Hood inlet & Capture tubes Replace Air Flow Filter Restricted Check Leads at Unit ICS-360...
APPENDIX 1A - ELECTRICAL DIAGRAM MANUAL [120 VAC] Single-Phase Power Disconnect power before performing any maintenance on unit, including filter ELECTRIC inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. Do not touch live electrical HAZARD parts.
APPENDIX 1B - ELECTRICAL DIAGRAM MANUAL [230/460/575V] 3-Phase Power ELECTRIC Disconnect power before performing any maintenance on unit, including filter inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. Do not touch live electrical HAZARD parts.
APPENDIX 2 - MAINTENANCE RECORD Diversitech Inc. authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance records. MANUFACTURER: DIVERSITECH INC. MODEL N° FRED-SR SERIAL N° SERVICE LOCATION: CONTROL N° Date Description of Service Serviced By...
APPENDIX 3 - ARM-TO-BLOWER DIRECT INSTALLATION 3.1 Unpack capture arm, hood, and base Capture Arm Swivel Base STEP 1. Unpack capture arm, hood, and base. Vent Hood 3.2 Attach swivel base to mounting plate STEP 2. Attach swivel base to mounting plate. •...
Page 17
3.3 Attach capture arm to swivel base STEP 3. Attach capture arm to swivel base. Hardware Quantity Swivel Base Capture Arm Assembly 1/4’’ Bolt, Socket Cap 1/4’’ Washer 1/4’’ Locking Nut 1/4’’ Spacer • Insert Spacers (3) between Capture Arm Mounting Bracket. •...
Page 18
3.4 Install flex hose STEP 4. Install flex hose. • Mount Flex Hose to Swivel Base and Capture Arm. • Tighten Both Hose Clamps. Hardware Quantity Fred-SR Assembly Hose Clamps Flex Hose...
APPENDIX 4 - ARM TO REMOTE MOUNT BRACKET INSTALLATION 4.1 Wall mount bracket standard assembly STEP 2. Description of the bracket assembly. • Mount Swivel Base to Remote Mount Bracket. • Tighten all Bolts (8) with Washers (8) • Toque each bolt to 23 N m Hardware Quantity Bracket...
Page 20
4.4 Attach Capture Arm to Swivel Base (J-Bracket) STEP 4. Attach Capture Arm to Swivel Base. (J-Bracket) Quantity Hardware Swivel Base with J-Bracket • Insert J-Bracket between Capture Arm Mounting Bracket. Capture Arm Assembly • Thread Bolts (3) with Washers (3) through Mounting Bracket and J-Bracket. 3/8’’...
APPENDIX 5 - SAMPLE SAFETY STICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices: The machine is marked with safety stickers in appropriate places to remind the operator of safe working practices.
Diversitech Inc. will repair or replace, at our option, any defective parts which fail during the warranty period. This warranty is limited to replacement parts ONLY, and does not cover personal liability, property loss, normal wear;...
Need help?
Do you have a question about the FRED SR2 and is the answer not in the manual?
Questions and answers