5. Technical data
Mains connection:
Motor rating kW:
Mode of operation
Compressor speed min
-1
:
Operating pressure bar:
Pressure vessel capacity (in liters):
Theoretical suction power l/min.:
Sound power level L
in dB:
WA
K
uncertainty
WA
Protection type:
Weight of the unit in kg:
Oil (15W 40)
6. Before starting the equipment
Check the equipment for damage which
■
may have occurred in transit. Report any
damage immediately to the transport
company used to deliver the compressor.
Install the compressor in the vicinity of the
■
point of consumption.
Avoid long air lines and supply lines
■
(extension cables).
Make sure that the intake air is dry and
■
dust-free.
Do not install the compressor in a damp or
■
wet room.
The compressor may only be used in
■
suitable rooms (with good ventilation and an
ambient temperature from +5 °C to 40 °C).
There must be no dust, acids, vapors,
explosive gases or inflammable gases in the
room.
The compressor is designed to be used in
■
dry rooms. It is prohibited to use the
compressor in areas where work is
conducted with sprayed water.
The oil level in the compressor pump has to
■
be checked before putting the equipment
into operation (see 9.4).
13:15 Uhr
Seite 11
7. Assembly and starting
230 V ~ 50 Hz
Important.
Remove the transportation braces
1.8 kW
(between the compression pump and
S1
cladding) prior to initial start-up. If the
2850
transportation braces are not removed,
heat can build up and cause the
max. 8
compressor to ignite.
24
approx. 270
Important.
94
You must fully assemble the appliance
before using it for the first time.
4 dB
IP20
You will require the following tools for assembly
26,5
and installation:
0.3 l
2 x open-ended wrench size 13 mm (not
included)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting foot (8)
Fit the supplied supporting foot as shown in
Figure 6.
7.3 Fitting the air filter (15)
Remove the transportation stop (B) and screw
the air filter (15) to the equipment. (Fig. 7, 8).
7.4 Changing the transportation cover (A)
Remove the transportation cover from the oil
filler opening (21) and insert the supplied oil
sealing plug (16) into the oil filler opening. (Fig.
9,10).
7.5 Mains connection
The compressor is equipped with a mains
■
cable with shock-proof plug. This can be
connected to any 230V ~ 50 Hz shock-proof
socket which is protected by a 13 A fuse.
Before you use the machine, make sure that
■
the mains voltage complies with the
specifications on the rating plate.
Long supply cables, extensions, cable reels
■
etc. cause a drop in voltage and can
impede motor start-up.
In the case of low temperatures below
■
+5°C, motor start-up is jeopardized as a
GB/
IE
11