6. INSTALLATION - ELECTROSPOT 8000
! WARNING: Unplug from mains power supply before connecting cables and accessories.
6.1.
ELECTRICAL CONNECTION
Ensure that the machine is compatible with your mains supply.
6.2.
PNEUMATIC CONNECTION (fig. 2)
6.2.1. Connect to an air supply according to Section 4.
6.2.2. Connect the two Dinse plugs into the welder sockets.
6.2.3. Connect the two air lines and the control cable.
6.3.
MANUAL CLAMP, CLAMP STUDDER & GROUND CABLE CONNECTION (fig. 3)
6.3.1. Connect the two Dinse plugs into the welder sockets.
6.3.2. Plug in control cable.
6.4.
AIR PULLER & GROUND CABLE CONNECTION (fig 4)
6.4.1.
Connect the two Dinse plugs into the welder sockets.
6.4.2.
Plug in air-line from puller to welder air outlet and connect control cable.
7. FRONT PANEL - ELECTROSPOT 8000
The following describes the functions of the front panel key
buttons and meanings of symbols, and refers to fig. 5.
Key 1
Adjusts the spot welding time above or below
the default setting.
Key 2
Selects the appropriate sheet thickness.
Key 3
Key 4
ElectroSpot 8000/9500.V2 - 2 - 040903
fig. 3
5
fig. 2
fig. 5
fig. 4
6
7

Advertisement

Table of Contents
loading

Related Products for Sealey ELECTROSPOT 9500.V2

This manual is also suitable for:

Electrospot 8000

Table of Contents