EHFRA7C*A EHFRA7FC*A Installation/Care/Use Manual Fully Recessed Refrigerated ® Fountain with FLEXI-GUARD 35, 36 SEE FIG. 5 SEE FIG. 9 Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA- TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
Page 2
EHFRA7C*A EHFRA7FC*A EHFRA7C ROUGH-IN FINISHED FLOOR LINE FIG. 1 LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES). B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN (BOTH SIDES).
Page 4
EHFRA7C*A EHFRA7FC*A FIG. 4 NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 25) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. FIG. 5 3/8" O.D. UNPLATED 1/4" O.D. TUBE BUILDING WATER COPPER TUBE CONNECT WATER INLET...