2. INTRODUCTION / SPECIFICATIONS
One-handed straight type die grinder with aluminium body and trigger with safety catch. Chuck
accepts grinding points with Ø6mm shanks. SA67.V3 is supplied with a selection of popular sized
grinding points, two spanners and carry-case.
MODEL. . . . . . . . . . . . . . . . . . SA67.V3
Collect size . . . . . . . . . . . . . . . . . Ø6mm
Free speed . . . . . . . . . . . . . . 22,000rpm
Air consumption . . . . . . . . . . . . . . .4cfm
Operating pressure. . . . . . . . . . . . 90psi
Air inlet size . . . . . . . . . . . . . . . 1/4"BSP
Weight . . . . . . . . . . . . . . . . . . . . 0.60kg
Vibration level . . . . . . . . . . . . 3.38m/s2
Uncertainty value . . . . . . . . . . 1.35m/s2
Noise power . . . . . . . . . . . 102.94dB(A)
Noise pressure . . . . . . . . . . 91.94dB(A)
Ø6mm shanked stones . . . . . . . . . . 10
3. PREPARING TOOL FOR USE
3.1
Air Supply
recommended hook-up procedure is shown in fig 1.
WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the
die grinder. Too high an air pressure and unclean air will shorten the product life due to
excessive wear, and may be dangerous causing damage and/or personal injury.
3.1.1 Ensure die grinder air valve (or trigger) is in "off" position before connecting to the air
supply.
3.1.2 You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3 Drain the compressor's air tank daily. Water in the air line will damage the die grinder.
3.1.4 Clean the compressor's air inlet filter weekly.
3.1.5 Line pressure should be increased to compensate for unusually long air hoses (over 8
metres). The minimum hose diameter should be 1/4" i.D. and fittings must have the same
inside dimensions.
3.1.6 Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain
that all connections are secure.
3.2
Couplings.
Vibration may cause failure if a quick change coupling is connected directly to the die
grinder. To overcome this, connect a leader hose to the grinder. A quick change coupling
may then be used to connect the leader hose to the air line recoil hose. See fig 1 & 2.
fig.1
MODEL. . . . . . . . . . . . . . . . . SA671.V3
Collect size . . . . . . . . . . . . . . . . . Ø6mm
Free speed . . . . . . . . . . . . . . 22,000rpm
Air consumption . . . . . . . . . . . . . . .4cfm
Operating pressure. . . . . . . . . . . . 90psi
Air inlet size . . . . . . . . . . . . . . . 1/4"BSP
Weight . . . . . . . . . . . . . . . . . . . . 0.60kg
Vibration level . . . . . . . . . . . . 3.38m/s2
Uncertainty value . . . . . . . . . . 1.35m/s2
Noise power . . . . . . . . . . . 102.94dB(A)
Noise pressure . . . . . . . . . . 91.94dB(A)
Original Language Version
fig.2
SA67.V3, SA671.V3 (SP)
issue: 4 - 11/07/13