CellPath CellTec JAX-0300-00A User Manual

Mini section dryer, 220-240v 50-60hz ac/400 watts

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for CellPath CellTec JAX-0300-00A

  • Page 3: Table Of Contents

    Contents General Notes Specimen Safety User Safety Power Lead and Connection to Electrical Supply Specification Optional Accessories Location Operating Instructions Operating Instructions LEAN Timer Unit and Slide Rack Holder LEAN Timer Unit Operation Cleaning Instructions Miniature Circuit Breakers Latching Safety Cut Out Portable Appliance Testing Warranty Terms and Conditions Warranty Terms and Conditions...
  • Page 4: General Notes

    Dear Customer, Thank you for purchasing this piece of CellTec laboratory equipment. To get the best performance from your equipment and for your own safety please read these instruc- tions carefully before use. General Notes This product is designed for laboratory use only. Always follow good laboratory practice.
  • Page 5: User Safety

    The instrument requires no regular servicing, but CellPath Ltd do recommend an an- nual inspection, as detailed in the manual which will prolong the life of the instrument to ensure continued safety.
  • Page 6: Specification

    Specification The CellTec Mini Section Dryer is a small footprint instrument which can be placed at the microtome for improved laboratory workflow. The section dryer operates by circulating digitally controlled warm air from the base of the instrument, which rises through the slide staining racks. This efficient air flow across the surface of the slides enables sections to be rapidly dried, with sections dried in approximately 10-20 minutes at 65˚C. The instrument can be fitted with an optional LEAN Timer which enables a user to track the drying process for up to four racks.
  • Page 7: Location

    Location The product must be placed on a smooth, level and sturdy work surface. Suitable for use in ambient temperatures 5°C to 40°C with a maximum humidity 80% (temperature 31˚C) decreasing to 50% (temperature 40˚C). Operating Instructions Place the Mini Section Dryer on a smooth and level surface. Connect the mains plug to the electrical supply and switch on the socket (Ensure the power supply is properly earthed).
  • Page 8: Operating Instructions

    E. The heater indicator will illuminate to show heater activity. F. The instrument will then warm up to the desired temperature, you will observe the temperature rise on the display. G. The instrument is designed to warm up quickly (roughly 3 to 5 minutes to reach 60˚C at 220V). Example: For an instrument operating in a 220v region and set to maintain a temperature of 60˚C. The instrument will initially warm, and slightly over shooting the set target temperature (by between 1-2˚C). The heater will then stop and allow the instrument to cool and drop below the desired working...
  • Page 9: Lean Timer Unit And Slide Rack Holder

    Start/Stop Key - Rack 1 and 2: Press to start and stop countdown, Press to stop an alarm and reset count down timer. M (Memory) Key - For Rack 1 and Rack 2: Press and hold to set a memory time. 5. HR (Hour) Key - For Rack 1 and Rack 2: Press to adjust the hour value.
  • Page 10: Lean Timer Unit Operation

    LEAN Timer Head Operation Install the Slide Rack Holder/Identifier, making sure the holder locates correctly onto the four holes in the drip tray. Place a slide rack containing sections to be dried into position 1, 2, 3 or 4 in the Slide Rack Holder. Select the corresponding timer on the Lean Timer Head by pressing the corresponding blue button, Rack 1, Rack 2 etc.
  • Page 11: Cleaning Instructions

    Miniature Circuit Breakers Located on the rear of the bath. In the event of a fault, push back in to reset. If fault situation continues, please contact your Service Engineer or CellPath Ltd. Latching Safety Cut Out The latching safety cutout operates if the section dryer goes into a fault condition.
  • Page 12: Portable Appliance Testing

    4. CellPath Ltd will accept no liability, where in the opinion of the company the defect has been caused by damage due to the Customers failure to follow operating...
  • Page 13 8. If any goods or parts thereof are returned unnecessarily all cost involved, including a charge for inspection, handling and the return carriage must be paid by the sender. In no circumstances shall any of the goods be returned to CellPath Ltd without its prior written consent.
  • Page 14: Non Warranty Information

    It is the customers responsibility to ensure that the loan equipment is packed in the packaging provided by CellPath Ltd, in order that CellPath Ltd can arrange collection of the loan instrument. If the loan instrument is not packed and ready for collection within 48 hours of a repaired instrument being returned to the customer, costs for collection and equipment rental fee will be applied.
  • Page 15: Ec Declaration Of Conformity

    EC Declaration of Conformity We herewith confirm the following products: Mini Section Drier - JAX-0300-00A Conforms with requirements outlined by the following European Directives: Low Voltage Directive 2006/95/EEC EMC Directive 2004/108/EEC We confirm the declaration: Nickel Electro Limited Oldmixon Crescent Weston Super Mare North Somerset BS24 9BL United Kingdom Conforms with the requirements of the following standards: BS EN 61010:1 BS EN 61010:2.010 Safety requirements for electrical equipment for measurement, control and...
  • Page 16: Routine Inspection Recommendations

    Routine Inspection Recommendations: CellPath Ltd recommend that a simple annual inspection be made for all CellTec laboratory equipment in order that any malfunction can be identified and rectified as early as possible. This is to ensure user safety and prolong instrument life span. Recommended checks to be made: 1. Condition of Power Lead.
  • Page 17: Other Celltec Equipment Available

    Other CellTec Equipment Available: Part No. Description Digital Tissue Section Bath (Round) – UK/EU/USA Plug JAW-0300-00A Power Supply/ Rating:110/ 230V 50/60Hz AC/400 Watts Digital Tissue Section Bath (Round) - Lid JAW-0300-00L Slimline Slide Drying Hotplate – UK/EU/USA Plug JAY-0100-00A Power Supply/ Rating: 110/230V 50/60Hz AC/400 Watts Slimline Slide Drying Hotplate - Lid JAY-0100-00AL Block Trimmer Plus –...
  • Page 18: Wiring Diagram

    Wiring Diagram CellTec Mini Section Dryer...
  • Page 19: Spare Parts List

    Spare Parts List Description Part Number Quantity Required Temperature Controller JBA-EX1236-00A 1 Off Power Entry Module JBA-EX1151-00A 1 Off Neon Amber and Tags JBA-EL0100-00A 1 Off Mains Switch JBA-ES0272-00A 1 Off 3A Circuit Breaker JBA-EX1161-63A 2 Off Thermal Cut Out 100˚C JBA-EH1242-63A 2 Off 5A Fuse JBA-EF0516-00A 1 Off...
  • Page 20 CellPath Ltd. Tel: +44 (0) 1686 611 333 80 Mochdre Enterprise Park, Fax: +44 (0) 1686 622 946 Newtown, Powys, Email: sales@cellpath.co.uk SY16 4LE, Mid Wales, UK Internet: www.cellpath.co.uk...