Download Print this page

Napoleon Condo Pack CAGMMA Installation Instructions

Architectural louvers (grille)

Advertisement

Quick Links

CONDO PACK ARCHITECTURAL LOUVERS (GRILLE)
Ensure all parts are in the kit before
proceeding. Do not proceed if parts
are missing.
PROCEDURE
(
Please read entire instructions first.)
ARCHITECTURAL GRILLE IS DESIGNED TO BE INSTALLED
ONTO A WALL SLEEVE PRIOR TO CONDO PACK
INSTALLATION. IT IS RECOMMENDED THAT THIS STEP IS
PERFORMED AFTER CONSTRUCTION PHASE
HAS BEEN COMPLETED.
IMPORTANT
!
TESTING HAS SHOWN THAT THE INSTALLATION OF
ARCHITECTURAL GRILLE AFFECTS THE NORMAL
OPERATION OF THE CONDO PACK UNIT UNDER
CERTAIN OPERATING CONDITIONS.
THE FACTORY INSTALLED UPPER STAMPED GRILLE
MUST BE REMOVED FROM THE CONDO PACK
CABINET, PRIOR TO UNIT INSTALLATION INTO A WALL
SLEEVE. NO UNAPPROVED ARCHITECTURAL
GRILLE IS ALLOWED. UNAPPROVED
ARCHITECTURAL GRILLE AND IMPROPER
INSTALLATION WILL LEAD TO DETERIORATION
OF THE PERFORMANCE AND PREMATURE FAILURE
DUE TO ADDED RESTRICTION TO AIR FLOW.
2
1
8x
WASHER,
0.174ID x 0.375OD x
0.125" THK NYL 6/6
8x
#8 x 1" HEX DRIVE TEKS SS
STEP 2.
Use factory provided (8)
self-drilling screws and
(8) washers to fasten the grille onto wall sleeve .
Use only factory provided
plastic washer with screws. If not used, the screws will
damage the cabinet and obstruct the removal of the
cabinet at the end of life cycle.
IMPORTANT
!
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686 • w w w . n a p o l e o n h e a t i n g a n d c o o l i n g . c o m
(CAGMHA - for PSC CONDO PACK)
(CAGMMA - for PSS, PSE and PSH)

INSTALLATION INSTRUCTIONS

KIT CONTAINS :
QTY DESCRIPTION
1
GRILL, ARCHITECTURAL FOR PSC
1
GRILL, ARCHITECTURAL FOR PSS.PSE,PSH
8
SCREW, #8 X 1" HEX DRIVE TEKS SS
8
WASHER, 0.174ID X 0.375OD X 0.125" THK NYL 6/6
1
LEAFLET, ARCHITECTURAL GRILL INSTALL(CP)
!
5
2
3
6
7
4
8
THE GRILLE MUST BE SEALED ON ALL FOUR SIDES.
IN ORDER TO PREVENT WATER RUNOFF DIRECTLY
!
ONTO THE FINISH WALL, IT IS RECOMMENDED TO
INSTALL FIELD-SUPPLIED FLASHING UNDERNEATH
THE BOTTOM OF THE LOUVER.
1
TOP wall sleeve panel
Align the grille with the TOP wall sleeve panel
Architectural Grille
STEP1.
Align the architectural grille with the top wall sleeve panel.
3
ARCHITECTURAL GRILLE
DRAIN OPENINGS
DO NOT PLUG THE DRAIN OPENINGS
STEP 3.
Insure wall sleeve is sealed properly according to wall sleeve
installation procedure. Caulk all seams between the grille and
the FINISHED exterior walls. Seal the spaces using non-
hardening caulking compound. All seals must be weather
tight to prevent entrance of moisture and water into the
building. Care must be taken not to plug the drain openings.
PART #
KIT #
W305-0014
CAGMHA
W305-0015
CAGMMA
W570-0204
BOTH KITS
W735-0062
BOTH KITS
W415-2253
BOTH KITS
W415-2253 / 11.22.17

Advertisement

loading

Summary of Contents for Napoleon Condo Pack CAGMMA

  • Page 1: Installation Instructions

    Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686 • w w w . n a p o l e o n h e a t i n g a n d c o o l i n g .
  • Page 2 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686 • w w w . n a p o l e o n h e a t i n g a n d c o o l i n g .
  • Page 3 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686 • w w w . n a p o l e o n h e a t i n g a n d c o o l i n g .
  • Page 4 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686 • w w w . n a p o l e o n h e a t i n g a n d c o o l i n g .

This manual is also suitable for: