Download Print this page

Elkay SWIRLFLO EDFPB114C Installation, Care & Use Manual page 5

Fountains with flexi-guard

Advertisement

EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C
Figure 7 - EDFPBWM114C Panel Installation
30
14
28
Figure 8 - EDFPBWM114C Fountain Installation
Figure 9 - AP-99 Panel (Optional)
EDFPBW114C Installation
1. Wall should already be framed for the fountain using
the positioning dimensions shown in Figure 3. Shown
dimensions pertain to installation location (framing
25
must support up to 300 lbs. weight). These dimensions
are required for compliance with ANSI Standard A117.0.
2. Install rough-in plumbing as shown in Figure 3. Run
supply water inlet line through the back panel. Install a
service stop (not provided). Turn on supply water and
flush thoroughly.
3. Install back panel. Place the upper edge of the panel
above mounting plate on the wall. Slide the panel down
until it engages the mounting plate. Be sure back panel
is firmly engaged before releasing it. (See Figure 7)
4. Install fountain. Remove screw (Item 28) from cover
plate and slide cover plate (Item 14) toward basin. Mount
the fountain to the back panel and mounting plate with (4)
5/16" x 1" (25mm) long screws (Item 30 - provided).
Tighten securely. (See Figure 8)
5. Determine required length of waste line and cut to
appropriate length. 1-1/4" O.D. waste tube furnished.
1-1/4" slip trap, waste elbow and extension not provided.
6. Make water supply connections from service stop to
the 3/8" O.D. unplated copper tube coming out of the
strainer. Turn on water supply and check for leaks
(See Figure 14). Newly installed water supply line
should be insulated after leak check is completed.
CAUTION: DO NOT SOLDER tubes inserted
7. These products are designed to operate on 20-105
PSIG supply line pressure. If the inlet pressure is
above 105 PSIG, a pressure regulator must be
installed in the supply line. Any damage caused by
reason of connecting these products to supply line
pressures lower than 20 PSIG or higher than
105 PSIG is not covered by warranty.
8. Check stream height from bubbler. Stream height is
factory set at 35 PSI. If supply pressure varies
greatly from this, remove push button (Item 17 -
Figure 12) and adjust the screw on the regulator
(Item 19 - Figure 12). To remove push button,
26
remove setscrew from bottom of sleeve (Item 15).
Insert a small punch in screw hole and push up
while grasping the push button and pull forward
removing the push button. Clockwise adjustment
will raise stream height and counterclockwise
movement will lower stream height. For best
adjustment stream should hit basin approximately
6-1/2" from the bubbler. Reassemble push button
by pushing in on the button until the push buttom
catches in the sleeve. Reinstall the setscrew
(Item 31) in the sleeve (Item 15).
Page 5
into the strainer as damage to the
o-rings may result.
97921C (REV. C - 3/05)

Advertisement

loading

This manual is also suitable for:

Swirlflo edfpbwm114cSwirlflo seriesSwirlflo edfpbv114cSwirlflo edfpbwmv114c