Message 5 / New Trigger Setup (versions 1.02 and greater)
Note that the D5 can both transmit and receive trigger setups to and from a D4.
Data Format (following header):
Byte
7
0000 0101
8
0ggg gggg
9
0ggg gggg
-
-
18
0ggg gggg
19
0ggg gggg
20
0000 0ccc
21
0nnn nnnn
22
0xxx xxxx
23
0ddd dddd
24
0000 0ccc
25
0nnn nnnn
26
0xxx xxxx
27
0ddd dddd
-
-
64
0000 0ccc
65
0nnn nnnn
66
0xxx xxxx
67
0ddd dddd
68
0xxx xxxx
69
1111 0111
Messages 32 thru 52 / Single Drumset Only
These messages contain the same Drumset data structures as the Edit Buffer message
and are identical, with the exception of the opcode byte. When a D4 receives a complete Single
Drumset message it will automatically "Store" the data in one of the 21 memory locations (as
specified in the opcode) replacing the existing Drumset data for that slot. Its important to note
that this new Drumset data does not effect the edit buffer. For a detailed listing of the Drumset
data structure see the description under Message 1 / Edit Buffer.
Alesis D4/D5 Drum Modules Service Manual
Bit Field
Opcode = New Trigger Setup
Trigger 1 gain
Trigger 2 gain
---- ----
---- ----
Trigger 11 gain
Trigger 12 gain
Trigger 1 vcurve
Trigger 1 cross-talk
Trigger 1 noise floor
Trigger 1 decay
Trigger 2 vcurve
Trigger 2 cross-talk
Trigger 2 noise floor
Trigger 2 decay
---- ----
---- ----
Trigger 12 vcurve
Trigger 12 cross-talk
Trigger 12 noise floor
Trigger 12 decay
Checksum
EOX
Description
---
---
---
---
27
Range
(0-99)
(0-99)
---
---
(0-99)
(0-99)
(0-7)
(0-99)
(0-99)
(0-99)
(0-7)
(0-99)
(0-99)
(0-99)
---
---
(0-7)
(0-99)
(0-99)
(0-99)
(0-127)