Safety Thermostat Probe N8 On Flange Immersion Heater - Convotherm OEB Series Service Handbook

Table of Contents

Advertisement

Service Handbook OEB/OES/OGB/OGS
Connections for the CTC probes
wire
OEB/OES/OGB/OGS
1 =
Casing ground
green/blue
2 = green/red
Tip of probe gauge (+)
3-5 = green
Further gauge points
(+)
6 = white
Ground (-) measuring
points

6.5.4 Safety thermostat probe N8 on flange immersion heater

Safety:
The safety thermostat must be connected to the top heating element.
Instructions:
Slide the safety thermostat N8 all the way into the cable duct.
Assemble the safety thermostat with the cable spring above.
AS/11-2011
connectio
n-plan
X6/1
X6/2
X6/3-5
X6/6
above
Safety thermostat probe N8 for
immersion heater
Part no.: 500 21 03
Immersion heater
4
3
2
5 6
1
B10
6_05e_Probe assembly and replacing_b
Page 4 / 5