Digital Interface (Iec 61162-1 Edition 2) - Furuno DS-50 Operator's Manual

Doppler speedlog
Hide thumbs Also See for DS-50:
Table of Contents

Advertisement

DIGITAL INTERFACE (IEC 61162-1 EDITION 2)

Output sentences of channel 1, 2 (NMEA/CIF 1, NMEA/CIF 2)
VBW, VTG, VLW, VHW. (VTG is not output when the bottom echo has not been acquired. Heading
data in VTG and VHW is "null.")
Transmission interval
2 s for any sentence
Data transmission
Data is transmitted in serial asynchronous form in accordance with the standard referenced in2.1 of
IEC 61162-1. The first bit is a start bit and is followed by data bits, least-significant-bit as illustrated
below.
The following parameters are used:
Baud rate: 4800 Data bits: 8 (D7 = 0), parity none Stop bits: 1
19