HIWIN Modbus TCP User Guide
int8_t, uint8_t, int16_t and uint16_t
Parameters of data types int8_t, uint8_t, int16_t and uint16_t are used for digital inputs or outputs
and controller status. The parameter data are stored as below.
17 (0x0011)
( 00000000 00010001 )
int32_t and uint32_t
Parameters of data types int32_t and uint32_t are used for digital inputs or outputs and controller
status. The parameter data are stored as below.
2097169 (0x00200011)
( 00000000 00100000 00000000 00010001 )
float
If parameter data types are float, the parameter data are stored as below.
(0x3F59999A)
double
If parameter data types are double, the parameter data are stored as below.
Value
0.85
(0x3FEB333333333333)
HIWIN MIKROSYSTEM Corp.
Value
Value
Value
0.85
Register N (Start)
0x3333
( 00000000 00010001 )
Register N (Start)
0x0011
( 00000000 00010001 )
Register N (Start)
0x999A
Register N+1
Register N+2
0x3333
Functions Of HIMC Modbus TCP
Register N
0x0011
Register N+1 (End)
0x0020
( 00000000 00100000 )
Register N+1 (End)
0x3F59
Register N+3 (End)
0x3333
0x3FEB
3-4