Hiwin LA Series User Manual

Hiwin LA Series User Manual

Linear actuator
Hide thumbs Also See for LA Series:

Advertisement

CONTENTS
Important Notes and Operating Safety Regulation:
............................................................................................ 9
............................................................................................ 31
............................................................................................. 38
............................................................................................ 42
............................................................................................... 56
............................................................................................. 58
............................................................................................. 60
............................................................................................... 62
*The contents of this user`s manual are subject to change without notice. If you are
experiencing any technical difficulties or do not understand the contents of this manual,
please contact our technical representative or local distributors for assistance.
......................................................................................... 7
......................................................................................... 18
......................................................................................... 23
.................................................................................. 29
............................................................... 32
..................................................................................... 35
........................................................................ 35
................................................................................. 36
.................................................................. 36
.......................................................................... 39
............................................... 41
................................................................ 43
....................................................................................... 54
.......................................................................... 59
........................................................................ 61
..................................................................................... 64
........................................................................................ 66
...................................................................................... 67
.............................................................................. 68
.............................................. 5
............................................... 10
.............................................. 12
A99UE13-1304
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hiwin LA Series

  • Page 1: Table Of Contents

    A99UE13-1304 CONTENTS Important Notes and Operating Safety Regulation: Chapter 1 Linear Actuator LA Series User's Guide ..........5 1. Product Specification and Operation Environment ..................7 2. Installation Guide .................... 9 3. Caution Notice ..........10 4. Linear Actuator with Quick-Release User's Guide...
  • Page 2 A99UE13-1304 Important Notes: 1. Please carefully read this operation manual before using this product. We don't take responsibility for any damage, accident or injury possibly caused by those who didn't follow these notes to install. 2. Don't disassemble or reinstall this product yourself. Since this product is designed under structural operation, computer simulation or physical test, it can't be disassembled or reinstalled without specialist's permission.
  • Page 3 A99UE13-1304 Operating Safety Regulation: 1. While operating an actuator, don't interrupt the motor operation to avoid failures in motor or mechanical structure. 2. Please follow the directions and use the nominal voltage of actuator motor with DC voltage. The supplied DC voltage can provide the maximum current at the maximum load.
  • Page 4 A99UE13-1304 12.Type of protection of applied parts against electric shock is BF. 13.The temperature of Products under storage and transmission is -10℃~+50℃. 14.The clean method of product:Alcohol ( 70%) . 15.The procedure of the broken product:Recycle by local rules. 16.The product should be installed in a safe place where is allowed to take off the plug easily in an emergency situation.
  • Page 5: Chapter 1 Linear Actuator La Series User's Guide

    A99UE13-1304 Chapter 1 Linear Actuator LA Series User's Guide 1. Product Specification 1.1 Standard Performance: Max. Current (A) Max. Max. TYPE Push Force Pull Force Holding Speed (mm/s) 12VDC 24VDC Force (N) LAM1-1 4000 3000 4000 8-11 LAM1-2 2000 2000...
  • Page 6 A99UE13-1304 LAN1-2 4000 4000 4000 LAN1-3 3000 3000 3000 5-10 9-11.5 LAN1-4 2000 2000 2000 12-17 LAN2-1A 6000 5000 LAN2-2A 5000 5000 5-7.5 LAN2-3A 3000 3000 9-14 24VDC 24VDC(24Q) 24VDC 24VDC(24Q) LAN3-1 10000 6000 10000 4.5-8 7-11 LAN3-2 7000 6000 7000 6.5-9 9-13...
  • Page 7: Installation Guide

    A99UE13-1304 2. Installation Guide 2.1. Please ensure that the extension tube is in the "lowest position" before installing actuators. 2.1.1 The term "lowest position" in this user's guide refers to the position such that there is no further movement towards the DC motor while the actuator is powered on.
  • Page 8 A99UE13-1304 2.1.3 LAC1 Installation LAC3 Installation Installing Hole 4 - M8 Motor Fixing Hold 6-M6 2.2.The front and end joints of the linear actuator should be mounted onto two fixed positions on the main chassis. Locations of these fixed positions should be chosen according to the stroke length of the linear actuator (Users must be cautious that the two-way movement of linear actuator must be smooth and within the stroke length after installed onto the fixed positions).
  • Page 9: Caution Notice

    2.7. The entire installation is finished only if steps 2.1 to 2.6 are executed successfully. 2.8. HIWIN Mikrosystem Corp. cannot take any responsibility for any injuries and/or damages caused as a result of not complying with the clauses of this section.
  • Page 10: Linear Actuator With Quick-Release User's Guide

    A99UE13-1304 3.2.2 LAC1 Series LAC3 Series 3.3. For fixing the extension tube in this actuator on one guding mechanism, please refer to the installation guide. If it is not fixed on any mechanism, it could idle. 4. Linear Actuator with Quick-Release User ’ s Guide 4.1 LAN1、LAN2 Series: 4.1.1 Be sure the moving ambits of handle will not interfere with other mechanisms when assembling.
  • Page 11 A99UE13-1304 Load Load 5. LAN3 Series: 5.1.To avoid mistake touching, please put up warning notice on the mechanisms or lifters. 5.2.The way to active quick-release is pulling the handle as the following drawing. 5.3.When the speed of quick-release is too fast, please adjust the handle extending length immediately;...
  • Page 12: Chapter 2 Lak Series Controller User's Guide

    A99UE13-1304 6. LAN5 Series: 6.1.Be sure the release cable is normal extended without any crooked when assembling, and the end of wire is certainty fixed on the mechanisms or hospital beds. 6.2.To avoid mistake touching, please put up warning notice on the mechanism or facilities.
  • Page 13 A99UE13-1304 2. LAK2 Series: 2.1 LAK2 can combine uniaxial or bi-axial linear actuators. For the sake of safety, two actuators can't be operated simultaneously. Don't press the “△” key and “▽” key at the same time. 2.2 The output power of a controller is 108VA (The output voltage is 24VDC.). 2.3 LAK2 can be driven by DC (12VDC / 24VDC), which the output power depends on the maximum power of power supply.
  • Page 14 A99UE13-1304 5.4 LAK2B input voltage is 120VAC。 5.5 Fuse specification:3A/20mm, 10A/20mm(Battery). 5.6 Note: Please charge battery for at least 8 hours before initial use. 6. LAK2BN Series: 6.1 LAK2B can combine uniaxial or bi-axial linear actuators, and provide an intelligent controller as well as application software according to customer requirements.
  • Page 15 A99UE13-1304 8. LAK2J Series(UL approved only DC IN versions): 8.1 LAK2J can combine uniaxial or bi-axial linear actuators. 8.2 A portable controller is designed in this product driven by two 12VDC lead acid batteries with 4.5Ah without built-in transformer. 8.3 The EMERGENCY button on a panel can disconnect the function of a controller to protect customers users.
  • Page 16 10.3 A bolt is provided to avoid actuators cord and pluggable AC power cord from accidentally being removed as well as reduce the danger when using. 10.4 LAK4D can combine with HIWIN linear actuator LAN5, and has an anti-loose function to prevent an actuator from being removed; it is saving space and easy to install.
  • Page 17 A99UE13-1304 11.5 Externally connect the power supply to provide higher driving power. 11.6 Over current protection and slow start are provided to avoid customer misuse. 11.7 LAK4N can combine LAN1 to save the space and easily install (Please refer to the figure below.).
  • Page 18: System Overview

    A99UE13-1304 2. System Overview 1. LAK2LR Series: Taking LAM for example Control Box Power Card External Limit Wire Power LAP2-1 Key Box Motor Cord 2. LAK2 Series: Taking LAN2 for example...
  • Page 19 A99UE13-1304 3. LAK2B/LAK2BN Series: Taking LAN1/LAC3 for example 4. LAK2D Series: Taking LAM3 and LAN1 for example...
  • Page 20 A99UE13-1304 5. LAK2J (DC-IN)Series: Taking LAN3 for example 6. LAK2J (AC-IN)Series: Taking LAN3 for example...
  • Page 21 A99UE13-1304 7. LAK4 Series: Taking LAN1 for example 8. LAK4D Series: Taking LAN5 for example...
  • Page 22 A99UE13-1304 9. LAK4N Series: Taking LAN1-LAC3 for example 10. LAK6B Series: Taking LAN1 and LAN2 for example...
  • Page 23: Installation Guide

    A99UE13-1304 3. Installation Guide Note: Don`t connect main power cord before completely connecting the whole system. 1. Installation of Linear Actuator and Controller Connector: When inserting an actuator connector to a controller chassis, please ensure a connector bolt aligns with a housing notch to insert. Push a connector into the bottom of a chassis until it is sure no gap between a connector and housing to ensure the IP class of the whole system (The installations of key box and controller are the same as above- mentioned.).
  • Page 24 A99UE13-1304 2.2 Step 2: 2.2.1 Before reinstalling a cover of battery box on a support, please lightly tighten screw B (Fig. 3) so that a cover of battery box will not shake while embedding the whole device. 2.2.2 Lock up slider (A) , and ensure it is completely and firmly installed on the whole device (Fig.
  • Page 25 A99UE13-1304 4.LAN5 and LAK4D Installation 4.1 Step 1: Align a bolt on LAK4D controller with a notch on LAN5 to insert downward(Fig. 1). There is a tube-bolt circled in the fig.2 to fix an actuator and controller. Fig. 1 Tube-Bolt Fig.
  • Page 26 A99UE13-1304 4.2 Installation of LAK4D Fixer: After inserting connectors of an actuator and a key box,vertically insert back the fixer on LAK4D controller (A) , and then fasten the up fixer and down fixer on LAK4D controller (Fig. 3). Before inserting the main power cord,rotate out the locker (B) along the arrow direction to insert power cord (Fig.
  • Page 27 A99UE13-1304 4.3.2 Using a screwdriver to prize the bottom of power cord fixer on LAK4D controller (Fig. 6-D). Fig. 6 5. LAN1 and LAK4N Installation: Align a bolt on LAK4N controller with LAN1 notch to insert downward(Fig. 1). There is one 3/16” *20 lock screw circled in Fig.2 to fix an actuator and controller.
  • Page 28 A99UE13-1304 6. Installation of LAK4N Fixer: Vertically and upwardly remove a fixer (A) from LAK4N controller. After inserting connectors of an actuator and key box, vertically insert back a fixer (Fig. 3) along the arrow direction. Before inserting main power cord, rotate out the locker (B) along the arrow direction to insert power cord (Fig.
  • Page 29: Basic Operation Guide

    A99UE13-1304 4.Basic Operation Guide 1. According to the axial number of actuator and the type of controller, a key box can only match with corresponding linear actuator. Example 1: Use a two-key box when combining a linear actuator (Please refer to the figure below.).
  • Page 30 A99UE13-1304 When you press the “▽” key, the extension tube of actuator will draw inward (Please refer to the figure below.). 3. LAP4G use guide : Align key with knob (Fig. 1),to turn left enables the actuator;to turn right disables the actuator.
  • Page 31: Caution Notice

    A99UE13-1304 4. When the extension tube travels to the end limit, the operation of an actuator will automatically stop (This function is suitable for LAS1, LAS2, LAS3, LAS4, LAM3, LAN1, LAN3,LAN3A, LAN5 ,LAC1 and LAC3 series only). 5. For LAM1 and LAN2 series, the operation of an actuator will stop when the extension tube travels to the external limit.
  • Page 32: Lakc-1 Over Current Protection Box

    LAKC-1. LAKC Over Current Protector Power IN (12/24VDC) HIWIN actuator 3.2 The input power (Power IN 12V/24VDC) is connected to the input connector of LAKC-1. 3.3 When the input power is connected (connecting as a figure below), the inner tube of...
  • Page 33 A99UE13-1304 3.4 When the input power is reversely connected (wiring as a figure below), the inner tube of actuator will draw inward. 3.5 When an actuator encounters an unknown obstacle during the operation or the overload time exceeds 0.8 seconds, LAKC-1 will automatically stop. 3.6 After activating LAKC-1, it means the working current has exceeded the rating.
  • Page 34 A99UE13-1304 4. Notice: 4.1 Please read a label of power supply indicated on over current protector before using this product, and ensure the supplied power can obey this product requirement. 4.2 Turn on the power after LAKC-1 over current protectors and actuators are installed. 4.3 If users select over current protector below 10A according to the product specifications, we recommend an input and output power cord within 5m with 1.25mm2 wire.
  • Page 35: Chapter 3 Sealed Lead Acid Batteries User's Guide

    A99UE13-1304 Chapter 3 Sealed Lead Acid Batteries User’s Guide 1. Battery Specification Battery Nominal Dimensions Weight Internal Max. Max. Specification Voltage (mm) (kg) Resistance Discharge Charge (20Hr) (mΩ) Current (A) Current (A) 1.3Ah 0.39 2.9Ah 1.18 0.87 4.5Ah 1.83 1.35 1.
  • Page 36: Battery Charging Guide

    A99UE13-1304 3. Battery Charging Guide 1. LAK2B、LAK2BN、LAK4N 1.1. Remove the connector covers from a battery box to insert DC IN socket indicated at the left side of LAK2B box, and then plug in power cord. 1.2. CPU in a control box will automatically detect the battery capacity. If the power capacity is insufficient, it will automatically charge.
  • Page 37 A99UE13-1304 2. LAK6B Installation 3. LAK2J Installation 4. LAKCH-B and LAKB-3 Installation...
  • Page 38: Battery Notice

    A99UE13-1304 5. Battery Notice 1. Batteries will discharge in storage by itself to reduce the capacity. Therefore, they must be stored at a place around low temperature, dryness, no direct sunlight or fire. 2. During the storage period, batteries should be recharged once every 3 months (a place where the environmental temperature is below 25℃).The environmental temperature starts from 25℃...
  • Page 39: Chapter 4 La Series Products Wiring & Installation

    A99UE13-1304 Chapter 4 LA Series Products Wiring & Installation 1. Linear Actuator Motor Wiring Power Actuator Power Wire Model Polarity Audio Connector DIN 4 PIN Bare Wire WHITE BLACK BLACK LAM1 BLACK WHITE WHITE GREEN GREEN     WHITE BLACK...
  • Page 40 A99UE13-1304 Actuator Power Wire Power Model Polarity Audio Connector DIN 4 PIN Bare Wire WHITE BLACK BLACK LAN1 BLACK WHITE WHITE GREEN GREEN GREEN WHITE BLACK WHITE LAN2 BLACK WHITE BLACK GREEN GREEN GREEN WHITE BLACK WHITE LAN3 BLACK WHITE BLACK GREEN GREEN...
  • Page 41: Reed Switch Specification & Application Circuitry

    A99UE13-1304 Direction Down Bare wires 2. Reed Switch Specification & Application Circuitry: 1. Feature: Common-open Type (standard) with red LED Feature Specification Operation Voltage DC/AC 5~110V Operating temperature -10℃~70℃ Storage Temperature -20℃~70℃ Operation Current 30mA(Max.) ON Resistance 51Ω Protection Class IP67 Response Time ON+OFF<1 mS...
  • Page 42: Plc Examples

    A99UE13-1304 3. PLC Example: 1. Low-level Control (taking PLC for example) DC24V Blue DC24V DC24V Blue 2K =12mA < 30mA DC24V 2K =12mA < 30mA Brown Limit Switch PLC or Other interface 限制開關 Brown PLC or Other interface 限制開關 2. High-level Control (taking PLC for example) Blue DC24V Blue...
  • Page 43: Positioning Feedback Device Wiring

    A99UE13-1304 4. Positioning feedback device wiring Positioning feedback device wiring can be classified as 5-core bare wire and 4-pin connector described as follows: 1. LAS2、LAS3 Optical Sensor and Potentiometer Feedback 1.1 Bare Wire for Optical Sensor 位置回饋規格(Optical Sensor) WIRING COLOR REMARK BLUE (22AWG) YELLOW (22AWG)
  • Page 44 A99UE13-1304 1.3 Specification of Positioning Feedback (Optical sensor) Supply voltage 24VDC 12DC 5VDC Hight level 24VDC Hight level 12VDC Low level 0.2V/40mA PNP Low level 0.2V/40mA PNP Output PS.Open collector PS.Open collector (NPN) (NPN) 1.4 Bare Wire for Potentiometer 位置回饋規格(Optical Sensor) WIRING COLOR REMARK...
  • Page 45 A99UE13-1304 DIN Connector COLOR REMARK YELLOW OUTPUT BLACK MOTOR(+) WHITE MOTOR(-) 24/12VDC SHELL BLUE...
  • Page 46 A99UE13-1304 2. LAN1 Positioning Feedback (Hall Sensor) WIRING COLOR REMARK BLACK (AWG18) MOTOR(+) WHITE (AWG18) MOTOR(-) 位置回饋規格(Hall Sensor) GREEN (AWG24) RED (AWG24) 24/12VDC YELLOW (AWG24) OUTPUT Specification of Positioning Feedback (Hall sensor) Supply voltage 24VDC 12DC 5VDC High level 24VDC High level 12VDC Output Low level 0.2V/10mA Sink (NPN)
  • Page 47 A99UE13-1304 3. LAN2 Positioning Feedback (Hall Sensor) WIRING COLOR REMARK RED (AWG24) 24VDC YELLOW (AWG24) OUTPUT 位置回饋規格(Hall Sensor) GREEN (AWG24) WHITE (AWG20) MOTOR(+) BLACK (AWG20) MOTOR(-) Specification of Positioning Feedback (Hall sensor) Specification 24VDC 5VDC Hight level 24VDC Low level Output 0.2V/10mA Sink (NPN) 4-pin Connector...
  • Page 48 A99UE13-1304 DIN Connector COLOR REMARK YELLOW OUTPUT BLACK MOTOR(+) WHITE MOTOR(-) 24VDC SHELL GREEN 4. Positioning Feedback for LAN3 Potentiometer WIRING COLOR REMARK WHITE (AWG18) MOTOR(+) BLACK (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT RED (AWG24) 24VDC SHELL GREEN (AWG24) 4-pin Connector for Potentiometer SHELL 0.7mm DIN Connector...
  • Page 49 A99UE13-1304 5. LAN5 Positioning Feedback (Hall Sensor) WIRING COLOR REMARK WHITE (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT GREEN (AWG24) RED (AWG24) 24/12VDC BLACK (AWG18) MOTOR(+) Specification of Positioning Feedback (Hall sensor) Supply voltage 24VDC 12DC 5VDC Hight level 24VDC Hight level 12VDC Output Low level 0.2V/10mA Sink Low level 0.2V/10mA Sink...
  • Page 50 A99UE13-1304 6. LAC1 Positioning Feedback(Hall Sensor) and Potentiometer 6.1 Bare Wire for Positioning Feedback(Hall Sensor) WIRING COLOR REMARK WHITE (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT GREEN (AWG24) RED (AWG24) 24VDC BLACK (AWG18) MOTOR(+) 6.2 Specification of Positioning Feedback (Hall sensor) Supply voltage 24VDC 12DC 5VDC...
  • Page 51 A99UE13-1304 DIN Connector COLOR REMARK YELLOW OUTPUT BLACK MOTOR(+) WHITE MOTOR(-) 24VDC SHELL GREEN 6.4 Bare Wire for Potentiometer WIRING COLOR REMARK WHITE (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT GREEN (AWG24) RED (AWG24) 24VDC BLACK (AWG18) MOTOR(+) 6.5 4-pin Connectorfor Potentiometer SHELL 0.7mm DIN Connector...
  • Page 52 A99UE13-1304 GREEN YELLOW 7. LAC3 Positioning Feedback(Hall Sensor) and Potentiometer 7.1 Bare Wire for Positioning Feedback(Hall Sensor) WIRING COLOR REMARK WHITE (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT GREEN (AWG24) RED (AWG24) 24VDC BLACK (AWG18) MOTOR(+) 7.2 Specification of Positioning Feedback (Hall sensor) Supply voltage 24VDC 12DC...
  • Page 53 A99UE13-1304 DIN Connector COLOR REMARK YELLOW OUTPUT BLACK MOTOR(+) WHITE MOTOR(-) 24VDC SHELL GREEN 7.4 Bare Wire forPotentiometer WIRING COLOR REMARK WHITE (AWG18) MOTOR(-) YELLOW (AWG24) OUTPUT GREEN (AWG24) RED (AWG24) 24VDC BLACK (AWG18) MOTOR(+) 7.5 4-pin Connectorfor Potentiometer SHELL 0.7mm DIN Connector COLOR...
  • Page 54: Chapter 5 Lak\Lap Wiring & Installation

    A99UE13-1304 Chapter 5 LAK\LAP Wiring and Installation: 1. LAP1/LAP2 Wiring 1. LAP1/LAP2 for LAK2/LAK2D Circuit Diagram WHITE 1 UP Green 1 Down 2 UP BLUE 2 Down YELLOW BLACK SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK2/LAK2D Specification WHITE DC_12V 220mA...
  • Page 55 A99UE13-1304 2 LAP1/LAP2 for LAK4&LAK2LR Circuit Diagram WHITE 1 DN 1 UP SHELL YELLOW 2 DN BLACK 2 UP POWER-RED BLUE SHELL Ø 13.25mm 0.7mm Wiring Specification DIN Connector WIRING LAK4 & LAK2LR Specification WHITE Axis 1 UP 50mA BLACK Axis 2 DOWN 50mA YELLOW...
  • Page 56: Lap3 Wiring

    A99UE13-1304 2.LAP3 Wiring 2.1. For LAK2B GREEN BLUE GRAY BROWN 1-DN 1-UP YELLOW 470R POWER-GREED 2-UP 2-DN BLACK GREEN WHITE YELLOW SHELL SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK2B Specification DC_12V 220mA YELLOW BLACK LED-Green 10mA WHITE LED-Yellow 10mA GREEN...
  • Page 57 A99UE13-1304 2.2. For LAK2J 100% LED-G LED-G LED-G LED-G LED-G BL UE BROWN WHI T E GRAY SHE L L BL ACK Y E L L OW GRE E N RE D SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK2J Specification...
  • Page 58: Lap3N Wiring

    A99UE13-1304 3. LAP3N Wiring For LAK2BN BLUE YELLOW BROWN WHITE 1-UP 1-DN GRAY SHELL POWER-RED BLACK YELLOW 2-UP 2-DN GREEN GREEN SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK2BN Specification GRAY 220mA BLACK WHITE 10mA YELLOW 10mA GREEN LED_GREEN 50mA BLUE...
  • Page 59: Lap4/Lap4M/Lap4R Wiring

    A99UE13-1304 4. LAP4/LAP4M/LAP4R Wiring For LAK4 SHELL Ø 13.25mm 0.7mm Wiring Specification DIN Connector WIRING LAK4 Specification GRAY Axis 1 UP 50mA BLACK Axis 2 DOWN 50mA WHITE Axis 2 UP 50mA YELLOW Axis 3 DOWN 50mA GREEN Axis 4 DOWN 50mA BLUE Axis 4 UP...
  • Page 60: Lap4G Wiring

    A99UE13-1304 5. LAP4G Wiring For LAK4D & LAK4N GRAY BLACK WHITE YELLOW GREEN BLUE BROWN SHELL SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK4D GRAY Axis 1UP BLACK Axis 1 DOWN WHITE Axis 2UP YELLOW Axis 2 DOWN GREEN Axis 3UP BLUE...
  • Page 61: Lap4N/Lap4M/Lap4R Wiring

    A99UE13-1304 6. LAP4N/LAP4M/LAP4R Wiring For LAK4D & LAK4N GRAY(1UP) BLACK(1DN) WHITE(2UP) YELLOW(2DN) GREEN(3UP) BLUE(3DN) BROWN(4UP) RED(4DN) LED1 SHELL(GND) SHELL Ø 13.25mm 0.7mm Wiring Specification DIN connector WIRING LAK4N & LAK4D GRAY Axis 1UP BLACK Axis 1 DOWN WHITE Axis 2UP YELLOW Axis 2 DOWN GREEN...
  • Page 62: Lap5 Wiring

    A99UE13-1304 7. LAP5 Wiring 7.1. For LAK6B WHITE BLUE BROWN GRAY SHEEL BLACK YELLOW GREEN SHELL 0.7mm Ø13.25mm Wiring Specification DIN Connector WIRING LAK6B Specification GRAY Axis 2,4 UP 50mA BLACK WHITE 220mA YELLOW Address C 50mA GREEN Address B 50mA BLUE Axis 1,3,5 UP...
  • Page 63 A99UE13-1304 7.2. For LAK2J WHITE BLUE BROWN GRAY SHEEL BLACK YELLOW GREEN SHELL 0.7mm Ø13.25mm Wiring Specification DIN Connector WIRING LAK2J Specification GRAY Axis 2 UP 50mA BLACK WHITE 220mA YELLOW Address C 50mA GREEN Address B 50mA BLUE Axis 1 UP 50mA BROWN Axis 1 DOWN...
  • Page 64: Connector Drawings

    A99UE13-1304 True Table Description Axis 1,2 Control Enable Axis 3,4 Control Enable Axis 5 Control Enable No Used Charge 25 % LED ON Charge 50 % LED ON Charge 75 % LED ON Charge 100 % LED ON 8. Connector Drawings 1.
  • Page 65 A99UE13-1304 2. LAK2D/LAK2B/LAK2BN/LAK4/LAK4N/LAK4D/LAK6B Motor DIN drawings 3x Ø 1.6...
  • Page 66: Chapter 6 Appendix

    Duty Cycle Max. 10 %,Max. 2 min Note Note 510A090202600021 FA02C1200001 510A090202570041 FA0149340501 HIWIN MIKROSYSTEM CORP. HIWIN MIKROSYSTEM CORP. FAX:886-4-23550123 http://www.hiwinmikro.com : The product is qualified by CE. : The protective rank of anti-shock of this product is B. :A double protection of this product.
  • Page 67: Ip Rank Description

    A99UE13-1304 2. IP rank Description IP(INTERNATIONAL PROTECTION) CODES I P X X Degree of protection against water,effects of immersion in water. Degree of protection against solid foreign object Descriptions Not Protected (Dust) Protected against solid foreign objects of 50mm diameter and greater Protected against solid foreign objects of 12mm diameter and greater...
  • Page 68: Chapter 7 Product Use In Medical Bed

    A99UE13-1304 Chapter 7 Product use in Medical Bed 1. Special features Controller Handset Type LAK4D-DDDD-230-GE LAP4G-4-GE Controller power(Vin) AC 230 V Controller power(Vout) DC 24 V Duty Cycle 10%(Max. 2 min On) Protection Class Class II Actuator Type LAN5-41-1-405-24GE LAN5-21-1-60-24GE LAN5-21-1-110-24GE Max.
  • Page 69 A99UE13-1304 APPLIED STANDARDS AND GUIDELINES standard specify Electromagnetic compatibility - Requirements for household appliances, electric tools and similar EN 55014-1:2006 apparatus - Part 1: Emission (IEC/CISPR 14-1:2005); German version EN 55014-1:2006 Electromagnetic compatibility-Requirements for EN 55014-2:1997+A1:2001 household appliances, electric tools and similar apparatus-Part 2:Immunity-Product family standard.
  • Page 70 A99UE13-1304 2.LAN5 and LAK4D Installation Step 1: Align a bolt on LAK4D controller with a notch on LAN5 to insert downward(Fig. 1). There is a tube-bolt circled in the fig.2 to fix an actuator and controller. Fig. 1 Tube-Bolt Fig. 2 Step 2:(Release of LAK4D Fixer) a.Putting the plug of Handset in the socket of Controller (The housing is made ”...
  • Page 71 A99UE13-1304 Fig.3 Step 3: (Release of LAK4D Fixer) One side of the fixer can be released (Fig. 5) by strongly pressing both sides of the fixer on LAK4D controller (Fig. 4). Fig.5 Fig.4 Step 4: Using a screwdriver to prize the bottom of power cord fixer on LAK4D controller (Fig. Fig.6...
  • Page 72 A99UE13-1304 3.Handset Description Power (1)Operate the Handset: Adjust the back:Push this button if you want to adjust the back angle. Function:Adjust the back angle. (Down) Function:Adjust the back angle.(Up) Adjust the leg:Push this button if you want to adjust the leg angle. Function:Adjust the back angle.
  • Page 73 A99UE13-1304 (2)Locking Function: The key is an accessory to a LAP4G and that for lock function. (Fig. 1) Fig.1 Align key with knob (Fig. 2),to turn left enables the actuator;to turn right disables the actuator. Keypad Box Open Knob Lock Fig.2 Please stop turning while the key applied to the knob rotates about 45°,otherwise,the key will be damaged;the same situation in the opposite direction.
  • Page 74 A99UE13-1304 4.Cleaning and disinfecting Cleaning and disinfecting: (1)Clean all surfaces(medical bed) (2)If the bed has visible contamination, it must be disinfected by wiping after cleaning. Use approved disinfectants for each surface according to the products listed by the DGHM (German Organization for Hygiene and Microbiology). 5.Checklist of product Check of product Defect description...
  • Page 75 A99UE13-1304 6. Label Controller Keypad Type LAK4D-DDDD-230-GE 230 V. , lin HIWIN MIKROSYSTEM CORP. Current Limit Max. 5 A. , Vout : DC Output Power 72.5 Type : LAP4G-4-GE Internal Power V., Batery: _ Date : Mtg.Date Weight IP : 1.89 Kg ,...
  • Page 76 MEMO...
  • Page 77 MEMO...

Table of Contents