3.4 Basic Wiring Diagram
Summary of Parameter Settings
Code
Parameter
Main
frequency
Pr.000
source
selection
setting
source of run
Pr.001
command
Function
Explanation
d0000:Main frequency (first
paragraph) is determined
by the digital keypad, press
the up and down arrow
keys to modify
d0001:
Select
the
(first paragraph) is decided
main
(first
by the input analog signal
paragraph)
(DC 0 ~ +10 V) + (DC 4 ~
frequency
20mA);
source
parameters Pr.28 , Pr29,
Pr41, Pr.42 correctly
d0002:Main frequency (first
paragraph) is decided by
RS-485
interface
d0000: Run command is
determined
operator
d0001: Run command is
determined by
selection
of
terminals .STOP key is
running
valid
signal source
d0002: Run command is
determined
terminal
key is invalid
15
Chapter 3 Operation Panel
Parameter Value
Main
frequency
Please
set
communication
by
digital
external
by
external
decision,
STOP
Factory
Setting
d0000
the
d0000