Karda KD4000-2S Series User Manual

Economic inverter

Advertisement

Quick Links

KD4000 Series Economic Inverter
User Manual
Substantial. Economic. Utility
Green.Intelligent.Energy-Saving
Shenzhen Karda Electric Co.Ltd
www.szkarda.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KD4000-2S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Karda KD4000-2S Series

  • Page 1 KD4000 Series Economic Inverter User Manual Substantial. Economic. Utility Green.Intelligent.Energy-Saving Shenzhen Karda Electric Co.Ltd www.szkarda.com...
  • Page 2: Table Of Contents

    Chapter 1 Production Overview..............2 1.1 Precautions on commodity inspection and storage....2 Chapter 2 Installation and wiring..............3 2.1 KD4000-2S(220V) Series Installation Dimension......3 2.2 KD4000-4T(380V) Series Installation Dimension......4 2.3 KD4000-2S(220V) basic wiring diagram........5 2.4 SD4000-4T (380V) basic wiring diagram........6 2.5 Control circuit wiring................7 2.6 Safety Considerations..............8 Chapter 3 Operation Panel................
  • Page 3: Chapter 1 Production Overview

    Chapter 1 Production Overview Chapter 1 Production Overview 1.1 Precautions on commodity inspection and storage Before delivery, all goods are under strictly quality control and well packed. However it may damage during the international transportation, please check them carefully: 1. Check the package condition to make sure no damage happened during transportation 2.
  • Page 4: Chapter 2 Installation And Wiring

    Chapter 2 Installation and wiring Chapter 2 Installation and wiring 2.1 KD4000-2S(220V) Series Installation Dimension...
  • Page 5: Kd4000-4T(380V) Series Installation Dimension

    Chapter 2 Installation and wiring 2.2 KD4000-4T(380V) Series Installation Dimension...
  • Page 6: Kd4000-2S(220V) Basic Wiring Diagram

    Chapter 2 Installation and wiring 2.3 KD4000-2S(220V) basic wiring diagram...
  • Page 7: Sd4000-4T (380V) Basic Wiring Diagram

    Chapter 2 Installation and wiring 2.4 SD4000-4T (380V) basic wiring diagram...
  • Page 8: Control Circuit Wiring

    Chapter 2 Installation and wiring 2.5 Control circuit wiring The Control circuit wiring should be separated from the main circuit wiring. Do not put them together in one slot. Terminal marks: Terminal Terminal Function Supplement marks External multifunctional common terminal X1-COM The first input terminal 4 terminals can build up...
  • Page 9: Safety Considerations

    Chapter 2 Installation and wiring open point output NO-CM instruction signal closed point output NC-CM instruction signal Input terminal of analog FI-ACM 4 ~ 20mA current 0 ~ +10V / Maximum FV-ACM Input terminal of analog voltage output frequency +10V Speed instruction 10V-ACM Power for setting speed power...
  • Page 10 Chapter 2 Installation and wiring 4.The inverter should not joint ground with other high current loads, must be separated. 5.The ground wire should be shorter. 6.When the inverters are common ground, don’t make a ground loops. 7.Confirm the voltage and maximum current. 8.
  • Page 11: Chapter 3 Operation Panel

    Chapter 3 Operation Panel Chapter 3 Operation Panel 3.1 Operation panel description( digital keypad is optional) I. Digital Keypad Operation This digital keypad module includes two parts: display panel and keypad. The display panel allows the user to program the AC drive, as well as view the different operating parameters.
  • Page 12: Digital Keypad Parts And Functions

    Chapter 3 Operation Panel II. Digital Keypad Parts and Functions Functions For normal operating or programming mode (the key is always valid) . Must select programming mode to modify parameters If the drive is shut down due to a fault occurs, after troubleshooting, press this button will clear the error message.
  • Page 13: Explanation Of The Display

    Chapter 3 Operation Panel III. Explanation of the display Display illustration Display the operating frequency of inverter .The frequency instruction may from self frequency setting or from jog frequency or multifunctional terminal 1,2,3,4. If frequency originates from digital keypad, user can use UP DOWN KEY to set it and saved automatically Display the operating frequency output to motor Display the operating AC voltage input to inverter...
  • Page 14: Digital Keypad Operating Modes & Programming Steps

    Chapter 3 Operation Panel 3.2 Digital Keypad Operating Modes & Programming steps NOTES: :Display changes every time key is pressed.
  • Page 15: Please Observe Below Steps To Set Parameters

    Chapter 3 Operation Panel 3.3 Please observe below steps to set parameters...
  • Page 16: Basic Wiring Diagram

    Chapter 3 Operation Panel 3.4 Basic Wiring Diagram Summary of Parameter Settings Function Factory Code Parameter Parameter Value Explanation Setting d0000:Main frequency (first paragraph) is determined by the digital keypad, press the up and down arrow keys to modify d0001: Main frequency Main...
  • Page 17 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting d0003:Run command determined by the RS-485 serial communication interface, STOP key is valid d0004: Run command is determined RS-485 serial communication interface, STOP key invalid d0000: RAMP stop selection selection Pr.002...
  • Page 18 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Selection of acceleration and deceleration d0000: line Acc/Dec Mode Pr.011 curve(Note : Do not modify d0001: S curve Acc/Dec d0000 this parameter when motor is Mode running) Days accumulated Pr.012 d0000—d9999...
  • Page 19 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Please Setting when percentage of Pr.020 don’t need d000.0—d050.0% d008.0 braking DC current to current brake Setting time for DC Set up to 0 to Pr.021 current shut down d000.0—d025.0s d0000...
  • Page 20 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting d0002: Operation continues after momentary power loss. Track up from minimum output frequency. d003: refer to Pr025 Setting restarting time Pr.025 after d000.3—d005.0 s d000.2 momentary power loss Setting for the Max.
  • Page 21 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting selection) d0003 :Shutdown , Closing X5 will FWD motor instantly; During running, closing X5 will shut down motor instantly . Shutdown, closing X6 will REV motor instantly ; During running, closing X6 will shut down motor instantly d0000: Multiple speed command 1 d0001: Multiple speed command 2...
  • Page 22 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting d0021:Reserve Multi-function d0021: Reserve Pr.033 input 3 d0002 d0022:Reserve Notes: Do not set up several input terminals for JOG FWD or JOG Multi-function REV contemporary ; several input Pr.034 input4 d0003...
  • Page 23 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting input Set the rated speed Pr.043 d0000—d3000 d1500 motor Set the rated Pr.044 d0030—d0120% d0100 current motor Pr.045 load current d0000—d0099% d0040 for motor Torque compensation Pr.046 d0000—d0010 d0000 setting Set the torque...
  • Page 24 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting d0010:over torque attained d0011: external failure attained d0012: FWD attained d0013: REV attained Setting d0000: Active with standard motor action Pr.050 d0001: Active with special motor d0002 electronic d0002: Inactive thermal relay Setting for the...
  • Page 25 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Energy brake Pr.055 d0001—d9999 d0000 setting Count Count Pr.056 attained attained d0001—d9999 d0000 setting setting d0000: Displays the actual operating freq. (H) d0001:Displays the actual Function Output operating running speed Pr.057 display physical...
  • Page 26 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting d0000: FPWM=2.9KHz, Pr.063 Frequency d0000 d0001: FPWM=5.8KHz setting Auto reset Pr.064 d0000—d0010 d0000 after fault d0000: Fault records clear (No errors occurred ) d0001: Over-current (oc) d0002: Over-voltage (ov) d0003: Overheat (oH) d0004: Overload (oL) d0005: Overload 1 (oL1)
  • Page 27 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Second fault Pr.066 d0000 record Third fault Pr.067 d0000 record d0000: parameters can be written and read (need 5 to 10 minutes to reset) Parameter d0001: parameters are read only lock d0002-d0009: Reserved Pr.068...
  • Page 28 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Acceleration Pr.077 d00.01—d99.99 s d00.02 time 3 Deceleration Pr.078 d00.01—d99.99 s d00.02 time 3 Acceleration Pr.079 d00.01—d99.99 s d00.02 time 4 Deceleration Pr.080 d00.01—d99.99 s d00.02 time 4 Acceleration Pr.081 d00.01—d99.99 s...
  • Page 29 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Deceleration Pr.094 d00.01—d99.99 s d00.02 time 11 Acceleration Pr.095 d00.01—d99.99 s d00.02 time 12 Deceleration Pr.096 d00.01—d99.99 s d00.02 time 12 Acceleration Pr.097 d00.01—d99.99 s d00.02 time 13 Deceleration Pr.098 d00.01—d99.99 s...
  • Page 30 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Frequency Pr.111 d000.1—d120.0Hz d015.0 setting 8 Frequency Pr.112 d000.1—d120.0Hz d015.0 setting 9 Frequency Pr.113 d000.1—d120.0Hz d020.0 setting 10 Frequency Pr.114 d000.1—d120.0Hz d025.0 setting 11 Frequency Pr.115 d000.1—d120.0Hz d030.0 setting 12 Frequency Pr.116...
  • Page 31 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Set Pressure Pr.130 d00.00- -d10.00mpa d01.0 sensor range Target value Pr.131 d00.00- -d10.00mpa d00.4 of PID (MPa) Proportional Pr.132 d0000- -d0999 d0015 constant Integration Pr.133 d0000- -d0999 d0999 time Differential Pr.134...
  • Page 32 Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting Power Pr.145 frequency d000.1- -d900.0s d060.0 running time Frequency d0000:work in frequency conversion only Pr.147 d0000 conversion d0001:with power frequency Pr.148 Pr.149 Pr.150 Pr.151 Pr.152 d0000: internal PLC invalid d0001:program operation stop after 1 week Pr.153 AUTO PLC...
  • Page 33: Troubleshooting And Fault Information

    Chapter 3 Operation Panel Function Factory Code Parameter Parameter Value Explanation Setting AUTO memory function (this d0000:no memory Pr.154 data d0000 d0001:memory determines pause function) Pr.155 Timer 1 d000.0- -d999.9 d000.0 Pr.156 Timer 2 d000.0- -d999.9 d000.0 Pr.157 Timer 3 d000.0- -d999.9 d000.0 Pr.158...
  • Page 34 Chapter 3 Operation Panel motor is over current. The motor is short circuit or overload ,otherwise need to repair PWM circuit error, should power off for one minute. Then restart motor, if same error appears ,please repair the inverter IPM failure reasons: 1....
  • Page 35: Chapter 4 Quality And Guarantee

    Chapter 4 Quality and Guarantee Chapter 4 Quality and Guarantee Quality assurance in accordance with the following provisions: 4.1 12 months warranty 4.2 Offer lifelong paid service 4.3 Below failures is not guaranteed 1. Improper operation or repair without permission 2.
  • Page 36 Chapter 4 Quality and Guarantee Item Specification Panel given; external terminals Give operation give ;485 communication given command Panel given; analogy voltage given ; frequency setting analogy current input given ; external input signal acceleration and deceleration given ; function output signal 485 communication given of motion...