VOLTCRAFT 10 08 41 Operating Instructions Manual
VOLTCRAFT 10 08 41 Operating Instructions Manual

VOLTCRAFT 10 08 41 Operating Instructions Manual

Comfort control digital thermo-hygrometer

Advertisement

Quick Links

SCHIMMEL-HYGROMETER MS-10
BEDIENUNGSANLEITUNG
COMFORT CONTROL DIGITAL THERMO-HYGROMETER
OPERATING INSTRUCTIONS
THERMOMÈTRE – HYGROMÈTRE DIGITAL COMFORT CONTROL
NOTICE D'EMPLOI
TERMO-IGROMETRO DIGITALE COMFORT CONTROL
ISTRUZIONI PER L'USO
DIGITALE THERMO-HYGROMETER COMFORT CONTROL
GEBRUIKSAANWIJZING
TERMO-HIGRÓMETRO DIGITAL COMFORT CONTROL
INSTRUCCIONES DE USO
Best.-Nr. / Item No. / N° de commande / Bestnr.:
10 08 41
SEITE 3 - 9
PAGE 10 - 15
PAGE 16 - 22
PAGE 23 - 28
PAGE 29 - 34
PAGE 35 - 40
VERSION 02/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10 08 41 and is the answer not in the manual?

Questions and answers

Summary of Contents for VOLTCRAFT 10 08 41

  • Page 1 ISTRUZIONI PER L’USO PAGE 23 - 28 DIGITALE THERMO-HYGROMETER COMFORT CONTROL GEBRUIKSAANWIJZING PAGE 29 - 34 TERMO-HIGRÓMETRO DIGITAL COMFORT CONTROL INSTRUCCIONES DE USO PAGE 35 - 40 Best.-Nr. / Item No. / N° de commande / Bestnr.: 10 08 41 VERSION 02/09...
  • Page 2 We are sure that your start with Voltcraft ® Plus is at the same time the beginning of a long and successful cooperation. We wish you lots of fun with your new Voltcraft ® Plus product! Features: • Room temperature •...
  • Page 3 Active heating and ventilation can help achieve a comfortable and healthy living environment and may even save you heating costs. The interaction of temperature and air humidity If the room air is too humid, ventilation would at first appear non- sensical in the winter, when the outside air is also cold, damp and just as humid.
  • Page 4 If the measuring unit indicates an air temperature of 20° C and a relative humidity of 65%, then the dew-point temperature will be 13.2° C. What does that mean? That the air, for instance in your bedroom, will condense and form water droplets at all points on walls and ceilings that are cooler than 13.2°...
  • Page 5 • If the room air is too dry, particularly in wintertime, then electrical air humidifiers are recommended, since airing at low outside tem- peratures will tend to decrease the humidity further. Duration of airing • A few minutes are mostly sufficient. Check the value indicated on your COMFORT CONTROL! Operation: Startup:...
  • Page 6 Since the humidity level within rooms can vary greatly according to the location, mount the unit so that it will monitor the conditions in a location likely to be subject to the most problems. Battery replacement: Open the battery compartment and insert 2 batteries 1.5 V AA. Clo- se the battery compartment.
  • Page 7 Technical Datas: Power Supply 2 x 1,5 V/DC (AA batteries) Measuring range Relative humidity: 1% to 99 % r.F. Tolerance: +/- 3% Measuring range Temperature: -10°C to + 60°C Tolerance: +/- 1% SWISS PRECISION SENSOR Our Swiss precision hygroTECH sensor gives a particularly rapid and accurate display of the air humidity.

Table of Contents