IKA LOGIC SQ Series User Manual

4 channels, 200 msps logic analyzer and pattern generator

Advertisement

Quick Links

SQ Series User Manual
SQ /SQ /SQ
/SQ
channels,
MSPS logic
analyzer and pattern generator
www.ikalogic.com | support@ikalogic.com
August
,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SQ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for IKA LOGIC SQ Series

  • Page 1 SQ Series User Manual SQ /SQ /SQ channels, MSPS logic analyzer and pattern generator www.ikalogic.com | support@ikalogic.com August...
  • Page 2: Table Of Contents

    SQ Series User Manual SQ /SQ /SQ Contents SQ Series overview Typical applications ........
  • Page 3 SQ Series User Manual SQ /SQ /SQ Limited warranty & limitation of liability Document Revisions (c) Ikalogic SAS...
  • Page 4: Sq Series Overview

    Generated signals may be arbitrarily created signals, or alternatively, user may play back previously captured signals Figure : SQ Series logic analyzer devices (From le to right: SQ , SQ , SQ , SQ ) SQ devices o er an intuitive way of analyzing logic signals, backed with exciting features like enhanced ±...
  • Page 5: Typical Applications

    SQ Series User Manual SQ /SQ /SQ Di erential input pairs Typical applications By combining logic analyzer and pattern generator capabilities in a single low price device, SQ is a perfect solution for students and small design houses. For more channels and more performances, check SP series logic analyzers.
  • Page 6 SQ Series User Manual SQ /SQ /SQ • Generate test patterns to stimulate a system without any other equipment. (c) Ikalogic SAS...
  • Page 7: Warning

    SQ Series User Manual SQ /SQ /SQ Warning Read safety information section carefully before using this instrument. (c) Ikalogic SAS...
  • Page 8: Main Characteristics

    SQ Series User Manual SQ /SQ /SQ Main characteristics Operating conditions Model SQ /SQ /SQ Temperature °C to °C Relative humidity < % non condensing Altitude < Timing and measurements Sampling rate Fastest measurable digital signal Maximum output frequency (generator mode) Sampling Period (Max.
  • Page 9: Outputs Specifications

    SQ Series User Manual SQ /SQ /SQ Low level input Adjustable Adjustable Adjustable voltage (Max) High level input Adjustable Adjustable Adjustable voltage (Min) Input threshold hysteresis Outputs specifications Output series resistance Output current (Max. per channel) Output high level . V (Fixed) .
  • Page 10: Principle Of Operation

    USB port performance Versatile trigger system SQ series o er a state of the art trigger system. It’s composed of one FlexiTrig®trigger engines, each FlexiTrig engine can be used in one of those modes: •...
  • Page 11: What's In The Box

    • Protocol based trigger (e.g. I C bus address or serial UART character) Finally, an external trigger input and output is available via an accessory called TrigBox. What’s in the box SQ series is shipped with the following items: . SQ device . USB cable (mini-B to A)
  • Page 12: Capturing Your First Signal

    SQ Series User Manual SQ /SQ /SQ a er the so ware and drivers have been installed. Once the so ware is installed, run it, and create a new workspace by selecting the model that match your SQ device from the list of possible choices.
  • Page 13: Mechanical Data

    SQ Series User Manual SQ /SQ /SQ Mechanical data Weight: g depending on model) Figure : SQ device dimensions (mm) (c) Ikalogic SAS...
  • Page 14: So Ware Technical Requirements

    SQ Series User Manual SQ /SQ /SQ So ware technical requirements Download ScanaStudio so ware on www.ikalogic.com so you can use your device on your favorite platform. SQ devices and ScanaStudio were tested to supports the following platforms: • Windows / / •...
  • Page 15 SQ Series User Manual SQ /SQ /SQ reception which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna.
  • Page 16: Safety Information

    SQ Series User Manual SQ /SQ /SQ Safety information This product complies with safety standards IEC NF/EN , IEC NF/EN and UL To prevent possible electrical shock, fire, personal injury, or damage to the product, read all safety information before you use the product. The following international symbols are used on the product and in this manual.
  • Page 17 SQ Series User Manual SQ /SQ /SQ • Do not use the product if it operates incorrectly. • Before use, inspect device casing, probes, test leads and accessories for mechanical damage and replace if damaged. • Never attempt to repair a defective device. Contact a er-sale service.
  • Page 18 SQ Series User Manual SQ /SQ /SQ OR FITNESS FOR A PARTICULAR PURPOSE. IKALOGIC SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since...

This manual is also suitable for:

Sq100Sq25Sq50Sq200

Table of Contents