CHARGING

Indication Description
Error mode
1.
Desulphation
2.
Soft start
3.
Bulk
4.
Absorption
5.
Analyze
6.
Float
7.
Pulse
Power on
Error mode
The charger suspends the charging / voltage maintenance.
Reset
Error mode is acknowledged/reset by pressing the "RESET" button.
RESET
6
STEP 1:
DESULPHATION
Detects sulphated batteries. Pulsing current and voltage removes
sulphate from the lead plates of the battery restoring the battery
capacity.
STEP 2:
SOFT START
Tests if the battery can accept a charge. This step prevents charging a
defective battery.
STEP 3:
BULK
Charging with maximum current until approximately 80% battery
capacity.
STEP 4:
ABSORPTION
Charging with declining current to maximize up to 100% battery
capacity.
STEP 5:
ANALYZE
Tests if the battery can hold charge. Batteries that cannot hold
charge may need to be replaced.
STEP 6:
FLOAT
Maintains the battery voltage at maximum level by providing a
constant voltage charge.
STEP 7:
PULSE
Maintains the battery at 95–100% capacity. The charger monitors
the battery voltage and gives a pulse when necessary to keep the
battery fully charged.