Onan 25.0 DEH-53R Series Operator's Manual And Parts Catalog page 7

Electric generating sets
Table of Contents

Advertisement

TABLE I. UR GENERATOR VOLTAGE/CURRENT OPTIONS
VOLTS
FREQ
PHASE AMPERES
DOUBLE
S E R I E S
PARALLEL
S E R I E S
REF V O L T A G E
DELTA
DELTA
WYE
WYE
WIRE (W12) TAP
110/220
50 Hz
1
142*
X
H6
115/230
50 Hz
1
136*
x
H6
120/240
60 Hz
1
156*
x
H5
110/190
50 Hz
3
95
X
H3
115/200
50 Hz
3
90
X
H4
.
120/208
50 Hz
3
87
X
H4
120/208
60 Hz
3
104
X
H3
110/220
50 Hz
3
82
x
H6
'
127/220
50 Hz
3
82
X
H5
127/220
60 Hz
3
98
X
H4
115/230
50 Hz
3
78
x
H6
120/240
60 Hz
3
90
X
H5
139/240
60 Hz
3
90
X-
H5
220/380
50 Hz
3
47
x'
H3
230/400
50 Hz
3
45
x
H4
240/416
50 Hz
3
43
x
H4
240/416
60 Hz
3
52
x
H3
• 254/440
50 Hz.
3
41
x
H5
254/440
60 Hz
3
49
x
H4
.
277/480
60 Hz
3
45
X
H5
9X
H5—Not
347/600
60 Hz
3
36
Reconnectible
3
.
H5—Not
120/240
60 Hz
1
'
L
156
Reconnectible
30 kW 37.5 kVA 60 Hz
25 k W 31.25 kVA 50 Hz
* - These current values are available only from special long stack units (Bl 25 option). When standard 3 phase unit is connected
into Double Delta configuration, maximum current is 2/3 that of value given.

Hide quick links:

Advertisement

Table of Contents
loading