Troubleshooting

8
Troubleshooting
Problem
No cooling
capacity
No heating
capacity
Low air output
12
Cause
The under-bench air conditioner is not
set to cooling.
The ambient temperature is above 52 °C. The under-bench air conditioner is
The temperature set is higher that the
room temperature.
The ambient temperature is below 16 °C. The under-bench air conditioner is
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
The under-bench air conditioner is not
set to heating.
The ambient temperature is below 0 °C.
The temperature set is lower than the
room temperature.
The ambient temperature is higher than
31 °C.
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
The air filter is obstructed.
The heat exchange coils are polluted.
The internal blower is defective.
FreshWell3000
Remedy
➤ Set the under-bench air
conditioner to cooling.
only designed for ambient
temperatures of up to 52 °C.
➤ Select a lower temperature.
only designed for ambient tempera-
tures above 16 °C.
➤ Contact an authorised workshop.
➤ Set the under-bench air
conditioner to heating.
The under-bench air conditioner is
only designed for ambient
temperatures higher than 0 °C.
➤ Select a higher temperature.
The temperature is adjustable
between 16 °C and 31 °C.
➤ Contact an authorised workshop.
➤ Clean the air filter.
➤ Contact an authorised workshop.