Operating Instructions Battery-Powered
Important:
Read these operating instructions and keep them. Make note of and follow the safety notices.
Table of Contents
Battery Powered Carbon Monoxide (CO) Detector
1.Introduction ............................................................18
2. Package contents ..................................................18
3. Technical data ........................................................19
4. Operation and Mounting ......................................21
5. Maintenance............................................................29
6. Disposal ....................................................................30
7. Guarantee ................................................................30
1. Introduction
These operating instructions must be read completely and carefully. They are a component of your newly purchased, battery-operated,
carbon monoxide detector and contain important information concerning its operation and maintenance. In the following, it will be
referred to only as the detector. All safety notices are to be observed in the use of this product. If you have any questions concerning the
use of this product, contact your dealer or our service office. These operating instructions are to be kept and must if necessary be passed
on to third parties.
2.Package contents
Immediately after unpacking the contents of your detector's package must be checked for completeness. Also check the detector itself for
proper condition.
1 x CO-detector CM L 4050
3 x 1.5 V AA batteries
2 x screws
2 x anchor bolts
1 x operating instructions
3.Technical data
The CO-detector is calibrated so that it sounds in response to the following CO-values, in compliance with EN 50291-1:2010 + A1:2012.
CO concentration No alarm
50 ppm
60 min.
300 ppm
-
Protection class:
IP 20
Power:
4.5 V (3 x AA 1.5 V)
Max. current:
< 55 mA (alarm)
Sound level of signal: 85 dB (1 m distance) Battery life:
ATTENTION:
IMPORTANT!
THIS IS NOT A SMOKE ALARM! This CO-detector was developed to detect carbon monoxide coming from ANY combustion source. It was
NOT developed to detect smoke, fire or other gases.
WARNING!
This detector is only intended for use in dry rooms. Use outdoors or in moisture-prone rooms is not permitted. In order to assure the
protective function of the detector, the LED POWER must be checked at regular intervals (see the table Alarm Signals and LED-Display).
Cover the detector during remodelling work but remember to remove the covering after the remodelling is complete (excessive paint
fumes, solvents, cleaning solutions, etc. can damage or impair the sensor). The CO-detector is no substitute for regular maintenance of
heating plants or having the chimney swept.
WARNING!
This device is intended to protect persons from the acute effects of carbon monoxide. It cannot offer persons with special medical
characteristics complete security. In case of doubt, you should consult a physician.
WARNING!
If the CO detector is manipulated, there is a risk of a malfunction and/or an electrical shock.
4.Operation and Mounting
In this chapter, the basic functions of the detector are explained. Read through this chapter carefully so that you understand and can use
all functions.
4.1 Selection of the Mounting Site
CO-Detector CM L 4050
Alarm in the air
before
90 min. 100 ppm
10 min.
3 min.
before
40 min.
5 years Device service life: