Contents Copyright information ................2 Description of common symbols ............2 Essential knowledge for users ............2 Safety precautions ................2 Disclaimer ..................2 Packing list ..................3 Schematic diagram of the whole equipment ........4 Connection steps for the whole equipment .........4 Technical parameters ...............6 Description of normal working interface ..........7 Selection method of working interface ..........7 Operations of air volume / temperature setup...
(natural disasters, etc.) or personal behavior during the operation of this product. This manual is organized, compiled and released by SHENZHEN ATTEN TECHNOLOGY CO., LTD. according to the latest product features. We will not be responsible for further notice of the subsequent...
Packing list GT-8102 host Hot air handle Vacuum pen compatible Tool box GT-8102 hot air desoldering station user manual Manual Double-male-connector Power line Spray nozzle Suction disc Spring Suction nozzle Handle holder Conformity certificate GT-8102 packing list GT-8102 host 1 Set...
Schematic diagram of the whole equipment Rapid temperature key 3 / System setup Hot air handle interface menu switching key Vacuum pen interface Power plug, connected to rated AC power Down arrow key /minus key Power master switch Rapid temperature key 1 RS232 communication interface Confirm key / Menu key Handle holder interface...
Page 7
Connect to the signal line of dormancy Connect the vacuum pen switch(With dormancy function, thus ensuring effective use of products and energy-saving.) Press power button, and the equipment Connect the charger can be started or shut down. Warning When replacing the hot air handle, be sure to turn off the power switch of host, and unplug the power plug, to avoid electric shock.
Technical parameters Product model GT-8102 Rated operating voltage AC 230V±10% 50hz (110v±10% 60hz, optional) Rated power 1000W(Max) Power fuses T 6.3A (230VAC) T 12A (110V AC) Setting range of temperature 100℃ ~ 480℃/ 212℉ ~ 896℉ Setting range of air volume...
Description of GT-8102 normal working interface Aften connected with charger turn on the power switch. the product will be working normally. Aften the screen display systen version for 3 seconds. GT-8102 startup interface 8102 Ver s io n: 1 . 00 ww w.atten.com...
Operations of air volume / Temperature setup Short press “MENU” key to switch the air volume setup and temperature setup. If selecting the icon , it means setting the Standby - - - air volume. If selecting the icon ℃, it means setting the temperature.
Enabling / Disabling of vacuum pen function In the normal working interface: 1. Long press the key “2” for 2sec, the vacuum pen function can be enabled, and the Standby icon “ ” will be displayed. - - - 2. Then long press the key “2” again and the vacuum pen function will be disabled.
If the configuration page is under the protection of password, the login to “Confirm” page shall be authorized. Press " " or " " key to change the input value, press “Enter" key to complete one Login input, and press the key "3" to return to the main interface.
Mode : Used to define the Host communication (not System set available yet). Net Address : Local communication address defined Mode during networking operation (not available yet). Net Address Factory Default : Used to resume the Host to the Factory Default factory settings.
Page 14
System set System lock-in 〉 〉System lock-in Password Under the password setup state, enter a three-digit password, Enter PIN System lock and display the prompt locked by the system. Press Enter to PIN: return to the password setup. System set System lock-out 〉...
Page 15
Net Address System set 〉Net Address Used for communication among many machines and System set can be connected to 255 devices at most: Password Adjustment range: 1~255 (used for function extension). * * * The factory default is: 1. Keypad Tone (The function has not been open) LCM Contrast Mode...
Total items of function setup menu In any setup mode, press the key “3” to enter the function / curve setup page, and the key “2” to enter the system setup page. UI Mode: Used for switching among interface modes. Function set Temp Offset: Used to compensate the error of temperature UI Mode...
Page 17
Temp Offset Function set 〉Temp Offset Used to compensate for the temperature output error o Function set hot air gun. UI Mode Compensation range: -50℃~+50℃, -90 ℉ ~+90 ℉. In case of a positive value, the hot air gun temperature Temp Offset will increase to the set value.
Page 18
Function set Function set 〉Temp Upper The maximum temperature that can be set by the user in Function set the main working interface. Shortcut Tmep 2 The set maximum temperature is 480℃/896℉. The set minimum value of the “maximum temperature” Shortcut Air 2 should be no less than or equal to the “minimum Shortcut Tmep 3...
Shortcut key of curve 2; long press to Short press to run the curve; long press run the vacuum pen function for curve setup Shortcut key of curve 3 Curve number plus GT-8102 curve working interface Profile Temp ℃ Time 103 s Current working curve number (1-25) Current remaining countdown time of curve Temperature scale;...
Page 20
Total items of curve setup menu In any setup mode, press the key “3” to enter the function / curve setup page; press the key “2” to enter the system setup page. UI Mode: Current working mode is curve mode. Profile Setup Edit Profile: Change the set curve parameters.
Page 21
For example: select Edit curve 4, and it needs to press “MENU” key again to enter Edit curve 4 (the default is empty curve). Edit Profile Selet Profile Empty Profile Step: Operational step during the operation of hot air handle Edit Profile (at most nine steps).
Page 22
Profile Setup Copy Profile Copy Profile 〉 Hold “MENU” key to enter the Copy curve. Profile Setup UI Mode Edit Profile Copy Profile Delete Profile Exit Source curve: Curve to be copied. Copy Profile Target curve: Curve generated after copying. Exit: Press “MENU”...
Page 23
Press “ ” or “ ” on the panel to select the Delete Profile curve to be deleted. Selet Profile After selecting the curve to be deleted, Delete Profile Press “ ” on the machine panel and the curve will not be deleted. Press “...
Care and maintenance Fault code or fault Likely causes of the faults description 1. The fan fails to rotate. E0: Abnormal fan 2. The fan sensor is damaged. 3. Poor contact. 1. The heating core is damaged; replace the heating core. E1: Open circuit of heating 2.
Product warranty ● This product is guaranteed for two years from the date of purchase (excluding consumables such as the heating core). If any quality problem is found within the guarantee period, we will response for the maintenance free of charge. ●...
Appendix Exploded view of the equipment Serial No. Material name Serial No. Material name Serial No. Material name Rear O ring Display lens Rubber air pipe Display board PCB Double-row EL2*3Y socket Brushless fan Silicone key Transformer Vacuum pump cover Interface aluminum Vacuum pump Bottom shell...
Product warranty card Product Certification This product is guaranteed for two years from the date of purchase. If any quality problem is found within the guarantee period, we will response for the Product Model: Product No.: maintenance free of charge on presentation of this card and the receipt.
Page 28
SHENZHEN ATTEN TECHNOLOGY CO.,LTD. ● Soldering iron ● Soldering station ● Hot air rework station ● Multi-function maintenance system ● Regulated DC power supply ● Switching DC power supply ● Programmable power supply All Copyright Reserved MADE IN CHINA CBN029720(A)
Need help?
Do you have a question about the GT-8102 and is the answer not in the manual?
Questions and answers