Duplomatic EWM-BUS-DD series 10 Startup Manual

Can coupler

Advertisement

Quick Links

EWM-BUS-DD/10
CAN Coupler
Start - up manual
Duplomatic MS S.p.A.
80946/118 ETM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EWM-BUS-DD series 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Duplomatic EWM-BUS-DD series 10

  • Page 1 EWM-BUS-DD/10 CAN Coupler Start - up manual Duplomatic MS S.p.A. 80946/118 ETM...
  • Page 2: Table Of Contents

    GENERAL INFO ..............................3 Contacts ..............................3 Safety instructions ............................4 Characteristics ............................... 5 INSTALLATION..............................6 Settings ..............................6 GSD configuration file ..........................7 Display ............................... 7 PROFIBUS socket ............................8 Device description ............................8 Duplomatic MS S.p.A. ▪ All rights reserved...
  • Page 3: General Info

    EWM-BUS-DD/10 80946/118 ETM GENERAL INFO This manual contains information about the EWM-BUS-DD series 10 used as Profibus / Canbus interface in systems for positioning or synchronization control of hydraulic axes. Identification code: 3809460001 EWM-BUS-DD /10 by Duplomatic MS S.p.A. Should you have any questions concerning just the card, please contact Duplomatic MS S.p.A., indicating the description, the code and the serial number written in the label on case side.
  • Page 4: Safety Instructions

    The module may not be used in an explosive environment. To ensure adequate cooling the ventilation slots must not be covered. The device must be disposed of in accordance with national statutory provisions. Duplomatic MS S.p.A. ▪ All rights reserved...
  • Page 5: Characteristics

    120 x 99(h) x 25(w) Connectors 2x4 poles screw terminals - PE direct via DIN rail Operating °C 0 / +55 temperature range Protection degree IP 20 housing Duplomatic MS ▪ EWM-BUS-DD/10 Start-up Manual – 80946/118 ETM --- Oct 2018...
  • Page 6: Installation

    Wire the CANBus of the coupler with the CANBus line of the master card for the axis control, as shown below: Connect the power supply: • pin 5 and pin 6 = 24 V • pin 7 and pin 8 = 0 V Duplomatic MS S.p.A. ▪ All rights reserved...
  • Page 7: Gsd Configuration File

    1: example for Duplomatic EWM-SS-DAD card configuration The tables below show the meaning of DIL Switches: GSD configuration file The .GSD file is available for download at www.duplomatic.com site, in the download section. Display The EWM-BUS-DD has a display that shows the module status:...
  • Page 8: Profibus Socket

    Use a shielded typical PROFIBUS connector (9-pin) with internal terminal resistors to be set properly. The pre-set address of the module can be changed only by Profibus (DEFAULT is 3). Device description Din Rail Clip Profibus port Diagnostic Display Duplomatic MS S.p.A. ▪ All rights reserved...

Table of Contents