schmersal FWS 2106 Operating Instructions Manual
schmersal FWS 2106 Operating Instructions Manual

schmersal FWS 2106 Operating Instructions Manual

Fail-safe standstill monitor

Advertisement

Quick Links

Operating instructions
Fail-safe standstill monitor
EN
Operating instructions...................... pages 1 to 6
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi dans
votre langue nationale oficielle
sur l'Internet, www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
oficiële landstaal op het
Internet, www.schmersal.net.
EU公用語で書かれた最新の取
JP
扱説明書は、インターネット
(www.schmersal.net)からダ
ウンロードできます。
Content
1
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Integral System Diagnostics (ISD) . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggiornato
IT
nella vostra lingua (lingua uficiale
UE) è scaricabile in Internet all'in-
dirizzo, www.schmersal.net.
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning for the safe operation
and disassembly of the safety-monitoring module. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualiied personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical speciications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-speciic installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modiications.
The entire concept of the control system, in which the
safety component is integrated, must be validated to
EN ISO 13849-2.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damages
to machinery or plant components cannot be excluded.
The relevant requirements of the standard EN 1088 must
be observed.
EN
FWS 2106
FWS 2506
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FWS 2106 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal FWS 2106

  • Page 1 3.2 Dimensions ......... . .3 Further technical information can be found in the Schmersal...
  • Page 2 ➀ 1 Hz/2 Hz Hysteresis: 10% of the standstill frequency 1 Hz/1 Hz Max. input frequency: FWS 2106: 4000 Hz FWS 2106: 125 μs Min. impulse duration: Outputs: Only if the information described in this operating instructions Stop category 0:...
  • Page 3 SIL: up to 2 Service life: 20 years Outputs FWS 2106: (13/14) NO contact for safety functions (enabling path) FWS 2506: (13/14)-(23/24)-(33/34)-(43/44) NO contacts for 3 Mounting safety functions (enabling paths) (51/52) NC contact for signalling purposes 3.1 General mounting instructions Mounting: snaps onto standard DIN rails to EN 60715.
  • Page 4 ≥ 50 mA the safety guard as a replacement for the NO contact of the AZM 161 in order to achieve PL d or control category 3. e.g. Schmersal IFL ..-..-10 P FWS 2106 AZM 161-12/12 22 41...
  • Page 5 Operating instructions FWS 2106 Fail-safe standstill monitor FWS 2506 Legend 8.2 Integral System Diagnostics (ISD) The LED indication of the safety-monitoring modules shows the different switching conditions and errors. The switching conditions Positive break are explained in the following tables.
  • Page 6: Ec Declaration Of Conformity

    Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal...

This manual is also suitable for:

Fws 2506

Table of Contents