Operating instructions (short version)
AS-i safety monitor
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
4.2 Pin configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.3 Wiring example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.4 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the
safe operation and disassembly of the safety monitor. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
Detailled information can be found in the wiring and operating
instructions manual as well as in the "asimon configuration
software" manual. These manuals can be found on the
"asimon CD".

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety monitor must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
ASM E1-R2
ASM E2-R2/R2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASM E1-R2 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal ASM E1-R2

  • Page 1 3.2 Dimensions ......... . .3 Further technical information can be found in the Schmersal...
  • Page 2 Switching voltage: max. 230 VAC ASM E1-R2: 3 A each output circuit; The safety monitor also executes the compulsory emergency stop ASM E2-R2/R2: 2 A each output circuit function (stop category 0 or 1) for all non hand-operated machines as Max.
  • Page 3 Operating instructions (short version) ASM E1-R2 AS-i safety monitor ASM E2-R2/R2 3. Mounting Note The transparent cover with attachment hook must always be installed, 3.1 General mounting instructions considering that it offers a good protection against electrostatic The AS-i monitor is fitted in the control cabinet onto 35 mm DIN rails discharges (ESD) and the penetration of foreign particles into the to EN 50022.
  • Page 4 Operating instructions (short version) ASM E1-R2 AS-i safety monitor ASM E2-R2/R2 4. Electrical connection ASM E1-R2 ASM E2-R2/R2 1. 1 3 1. 2 3 1. Y 1 1. 1 3 1. 2 3 1. Y 1 2. 1 3 2. 2 3 2.
  • Page 5 Operating instructions (short version) ASM E1-R2 AS-i safety monitor ASM E2-R2/R2 4.4 LED indications not used The LED indications located on the front of the AS-i safety monitor LED AS-i 1 provide information about the operating mode and the device status.
  • Page 6: Eu Declaration Of Conformity

    Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

This manual is also suitable for:

Asm e2-r2/r2

Table of Contents