4.2

Measurement specifications

Accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with
relative humidity at less than 80%.
Accuracy specifications take the form of: ± (% of Reading + Number of Least Significant Digits)

4.2.1 Voltage

DCV
Range
60 0 mV
6 V
6 0V
60 0 V
10 0 0 V
ACV
Range
60 0 mV
6 V
6 0V
60 0 V
75 0 V
Above accuracies can be guaranteed within 5%~100% of the full range.
The RMS meter has residual value within 10 counts when the test leads are shorten, but that will
not affect the accuracy of measurement.
1. Frequency Range for ACV: 40Hz~400Hz.
2. Response for ACV: RMS measure, calibrated in rms of sine wave.
3. Overload Protection: 1000V dc or 1000V ac rms.
4. Input Impedance (Nominal): DC voltage: >10MΩ; AC voltage: >10MΩ
16
" is displayed when the battery is under the proper operation
Resolution
0 .1 mV
±(0.5% of rdg +5 digits)
1 mV
1 0 mV
±(0.8% of rdg +5 digits)
1 0 0 mV
1 V
±(1.0% of rdg +2 digits)
Resolution
0 .1 mV
1 mV
±(1.0% of rdg + 5 digits)
1 0 mV
1 0 0 mV
1 V
±(1.5% of rdg + 5 digits)
BMMTRS1
Accuracy
Accuracy