Instructions Before Installation - Dometic MWE4104 Installation And Operating Manual

Blind spot assistant
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5

Instructions before installation

6
Instructions before installation
6.1
Painting the sensors
See fig. 2
I
NOTE
The sensors may be painted. The manufacturer recommends having the
sensors painted by a specialist workshop.
6.2
Determining the place of installation for the sensors
See fig. 3 to fig. 5
I
NOTE
The sensors must be correctly aligned for the device to work properly.
Do not install any other attachments in the detection area directly
around the sensor. Attachments in the detection area can lead to
reflections and errors.
Do not aim the sensors directly at the ground. If the sensors are
aimed directly at the ground, bumps may be displayed as an obsta-
cle, for example.
Do not aim the sensors too far up. If the sensors point too far up,
obstacles will not be detected at all.
Note the following during installation:
• The area around the sensors must be free from other objects.
• The distance from the sensors to the ground when horizontally aligned should be
at least 45 cm and a maximum of 120 cm (fig. 3).
• Note that the alignment of the sensor depends on the installation height.
According to the table in fig. 3, select the sensor holder with the suitable angle.
Supplementary to fig. 5
➤ Observe the intervals between sensors.
I
NOTE
You can also distribute the sensors as shown in alternative B and C.
6
MWE4104
EN

Advertisement

Table of Contents
loading

Table of Contents