BainUltra VIBE BACK TO WALL Installation Instructions Manual

Freestanding

Advertisement

Quick Links

VIBE BACK TO WALL
(FREESTANDING)
INSTALLATION INSTRUCTIONS
IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIBE BACK TO WALL and is the answer not in the manual?

Questions and answers

Summary of Contents for BainUltra VIBE BACK TO WALL

  • Page 1 VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER...
  • Page 2: Table Of Contents

    CUTTING TEMPLATES OF ELECTRONIC CONTROLS .....................24 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 3 VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS VIBE BACK TO WALL www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
  • Page 4: Important Safety Instructions

    • For indoor use only. 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 5 • Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to ® overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible ® for any water damage caused by improper installation (see Warranty section in the Owner’ s Manual).
  • Page 6: Parts & Tools

    * : REQUIRED WHEN NO ACCESS IS POSSIBLE UNDER THE FLOOR. 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 7 VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS PARTS & TOOLS REQUIRED STANDARD PARTS – THERMOMASSEUR ® DESCRIPTION Turbine MiaPlus Control ® MiaMulti Control (option) ® 15’ control cable PARTS & TOOLS Cutting template 48-inch level Measuring tape Teflon tape ABS & PVC Glue Square/Phillips #2 Screwdriver 3/4”...
  • Page 8: Site Preparation

    ThermoMasseur ® which includes information such as necessary dimensions of site before installation. If you do not already have the technical specifications, download it from the BainUltra ® Web site at: bainultra.com or call us at: 1-800-463-2187. 1 800 463.2187 Monday to Thursday from 8 a.m.
  • Page 9 VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS SITE PREPARATION TURBINE - REMOTE INSTALLATION 1. A 1 ½ inch ID pipe has to run from the tub, back to the turbine location. This pipe can be PVC Tigerflex (spa hose) or rigid PVC or ABS 2.
  • Page 10: Installation With Access Under The Floor

    PLUMBING PREPARATION – FLOOR LAYOUT FOR PIPES AND ACCESS VIBE BACK TO WALL NOTE : Please refer to the Cutting Template provided with your VIBE BACK TO WALL bath. However, if it is missing, please contact us at 1-800-463-2187 to order it.
  • Page 11 VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS INSTALLATION WITH ACCESS UNDER THE FLOOR* * FRONT OVERFLOW CONFIGURATION SHOWN. MAY VARY ACCORDING TO OPTIONS. PVC DRAIN PVC & BRASS DRAIN BRASS DRAIN www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
  • Page 12: Installation

    DRAIN CONNECTION Floor surface 1“ Maximum 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 13: Installation Without Access Under The Floor

    PLUMBING PREPARATION – FLOOR LAYOUT FOR PIPES AND ACCESS VIBE BACK TO WALL NOTE : Please refer to the Cutting Template provided with your VIBE BACK TO WALL bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. Available on our website at bainultra.com.
  • Page 14 PVC & BRASS DRAIN BRASS DRAIN 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 15: Installation

    VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS INSTALLATION WITHOUT ACCESS UNDER THE FLOOR BATH INSTALLATION STEPS TO FOLLOW • Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic.
  • Page 16 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 17: Remote Mounting Of Turbine

    VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS REMOTE MOUNTING OF TURBINE TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ® GEYSAIR HOSE AND FLOW REGULATOR 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX ® » FLEXIBLE PVC) FLOW REGULATOR 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX»)
  • Page 18: Installation

    ® 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674...
  • Page 19: Electrical Connections (Thermomasseur)

    VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS REMOTE MOUNTING OF TURBINE REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR ® • See page 23 for electrical diagram GEYSAIR BACK FLOW PREVENTER EXTENSION CORD (For extra extension cord length, contact BainUltra to order)
  • Page 20: Electronic Controls

    LOCATION: Determine the most convenient location, on the wall close to tub. WARNING • Vibe Back to wall bath cannot be drilled for control installation. DRILLING OF WALL: Refer to the Cutting Template on page 24 for the location and diameter of the holes.
  • Page 21: Electrical Section

    VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS ELECTRICAL SECTION ELECTRICAL CONNECTIONS FOR REMOTE MOUNTING OF TURBINE AND THERAPIES • See page 23 for electrical diagram. Jonction Box (Canada) To GFCI OUTLET (United States) Inmix module Geysair To right LED A : Chromatherapy (LED) B: MiaPlus ®...
  • Page 22: Electrical Connections For Remote Mounting Of Therapies (Tubs Without Air Jets)

    DOT Chromatherapy (LED) WARNING • VIBE Back to wall bath cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
  • Page 23: Electrical Diagrams

    VIBE BACK TO WALL (FREESTANDING) INSTALLATION INSTRUCTIONS ELECTRICAL SECTION ELECTRICAL DIAGRAM – 20A THERMOMASSEUR and 15A THERAPY ® 15A CIRCUIT 20A CIRCUIT 15A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND GROUND GROUND FAULT CIRCUIT...
  • Page 24: Cutting Templates Of Electronic Controls

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © February 2019 BainUltra Inc. All rights reserved. 45200674 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)