OPERATING INSTRUCTIONS
ALPHAiX 3000
TABLE OF CONTENTS
Page 2
Page 3
Page 4
Page 5
Page 6
Page 6
Page 7
Page 7
Page 7
Page 1 of 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALPHAiX 3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova ALPHAiX 3000

  • Page 1 OPERATING INSTRUCTIONS ALPHAiX 3000 TABLE OF CONTENTS General Page 2 2. Instructions for the 3 measuring methods Page 3 3. Programming the measuring times/measuring intervals Page 4 4. Other commands for controlling the ALPHAiX Page 5 5. Replacing the counter tubes Page 6 6.
  • Page 2: General

    OPERATING INSTRUCTIONS ALPHAiX 3000 General The ALPHAiX 3000 is a microprocessor-controlled radiation measuring instrument and also a programmable computer with storage facilities. Measurements can, of course, also be carried out without having to program the unit in advance. The principal basic functions:...
  • Page 3: Operating Instructions

    OPERATING INSTRUCTIONS ALPHAiX 3000 Instructions for the three measuring methods The 3 different measuring methods offer the chance to select the proper measuring method for each testing purpose. Single impulse determination corresponds to the customary contamination measuring method used till now and has therefore been retained.
  • Page 4: Programming The Measuring Times/Measuring Intervals

    OPERATING INSTRUCTIONS ALPHAiX 3000 Programming the Measuring Time/Measuring Interval The ALPHAiX allows setting of various measuring times in the IMPULSE mode or measuring intervals for display in IMP/m but not in µSv/h. As already mentioned, the new measuring intervals in the µSv/h and IMP/m measuring method are automatically started after the pre-selected measuring time and the measured value of the completed measuring interval is stored.
  • Page 5: Other Commands For Controlling The Alphaix

    OPERATING INSTRUCTIONS ALPHAiX 3000 Other Commands for Controlling the ALPHAiX 3000 PERIOD key The PERIOD key is used to program the measuring intervals.The currently set measuring time appears if PERIOD is pressed immediately after switching on. This measuring time display flashes if the SET key is depressed at the same time.The measuring time setting can be changed with the ↑/↓...
  • Page 6: Replacing The Counter Tubes

    1 minute before opening. The ALPHAiX 3000 operates up to a minimum voltage of 7 V. If the voltage is too low the message BATT appears in the display. It is advisable to replace the battery at a voltage of less than 8 V.
  • Page 7: Guarantee

    EDP measurement and analysis program The current ALPHAiX version contains an RS-232 interface for transferring data to a PC. All measured data including those stored in the ALPHAiX 3000 (up to 40 values) can thus be transferred. Scope of delivery for the electronic data processing (EDP) and analysis program includes a Windows program diskette/CD, instructions for use and a connection cable for the PCs COM1/COM2 port.