Maintenance; General; Flushing; Draining - State Water Heaters TPD-140-140 Instruction Manual

Models tpg-140-140 thru 600-2500 including tpx/tpo & tpd commercial gas, oil and gas/oil tank-type water heaters installation operation service maintenance limited warranty
Table of Contents

Advertisement

Suggested safety device test procedures are:
A. While heater is operating, turn valve, main burner and pilot
gas line manual gas cocks to the OFF position. Burner should
shutdown within 3-4 seconds and lockout on flame failure,
requiring reset of the flame safeguard device.
B. While heater is operating, lower the setting of each of (2)
operating thermostats (one at a time). During this setting
change, the burner should shutdown when the called for
temperature is less than the temperature indicated on the
thermometer. Restore the settings to original values and burner
should restart.
Should any of the above operating test fail, replace the involved
component.

MAINTENANCE

GENERAL

Water heater maintenance includes periodic tank flushing and
cleaning, and removal of lime scale. The power burner should
be inspected and adjusted to maintain proper combustion. Refer
to the following table. A periodic inspection of the venting system
should be made. Where used, the water heating system
circulating pump should be oiled.
KEEP APPLIANCE AREA CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER
FLAMMABLE VAPORS AND LIQUIDS.

FLUSHING

1. Turn off the heater electrical disconnect switch.
• For convenience, the switch on the outside of the control
compartment can be used.
2. Open the drain valve and allow water to flow until it runs clean.
3. Close the drain valve when finished flushing.
4. Turn on the heater electrical disconnect switch.
MAINTENANCE SCHEDULE
Component
Operation
Flushing
Sediment
Tank
Removal
Lime Scale
Removal
Relief Valve
Inspect
Power Burner
Motor(1)
Inspect
Power Burner
and Ignition
Inspection
Device(2)
Main Burner
Check Flame
Flue Baffle
Pipe(3)
Cleaning
Vent System
and Barometric
Inspect
Damper
(1) If furnished with oiling provisions
(2) If flange gasket is damaged, it must be repaired.
(3) TPO and TPD Only.
Interval
Required
Monthly
Semi-Annually
UN•LIME
®
As Required
Delimer
Semi-Annually
SAE No. 20
Quarterly
non-detergent
motor oil
Combustion
Semi-Annually
test kit &
test
specifications
Annually
As Required
Wire Brush
Semi-Annually Draft Gauge
The heater must be drained if it is to be shut down or exposed to
freezing temperatures. Maintenance and service procedures may
also require draining the heater.
1. Tun off the heater electrical disconnect switch.
2. Close the cold water inlet valve to heater.
3. Open a nearby hot water faucet to vent the system.
4. Open the heater drain valve.
5. If the heater is being drained for an extended shutdown, it is
suggested the drain valve be left open during this period.
• Follow FILLING instructions when restoring hot water service

SEDIMENT REMOVAL

Waterborne impurities consist of fine particles of soil and sand
which settle out and form a layer of sediment on the bottom of the
tank.
For convenience, sediment removal and lime scale removal
should be performed at the same time.

LIME SCALE REMOVAL

The amount of calcium (lime) released from water is indirect
proportion to water temperature and usage. The higher the water
temperature or water usage, the more lime deposits are dropped
out of the water. This is the lime scale which forms in pipes, heaters
and on cooking utensils.
Lime accumulation not only reduces the life of the equipment but
also reduces efficiency of the heater and increases fuel
consumption.
The usage of water softening equipment greatly reduces the
hardness of the water. However, this equipment does not always
remove all of the hardness (lime). For this reason it is
recommended that a regular schedule for deliming be maintained.
12

DRAINING