Download Print this page

State Water Heaters SRGSS00905 Specification Sheet page 2

Residential gas water heaters

Advertisement

S
ELECT
Residential Gas Water Heaters
FIRST
MODEL
HOUR
NUMBER
RATING
GALLONS
GS6 40 YBVIT
69
GS6 50 YBVIT
83
GS6 40 YBVIT 2
70
GS6 50 YBVIT 2
83
GS6 40 YRVIT
80
GS6 50 YRVIT
83
GS6 50 YRVIT 5
114
GS6 75 YRVIT*
N/A
*74-gallon model is not FVIR construction
Propane Inputs: GS6 40 YBVIT, GS6 50 YBVIT, GS6 40 YBVIT 2, GS6 50 YBVIT 2: 40,000 BTU, GS6 40 YRVIT
GS6 50 YRVIT: 50,000 BTU, GS6 50 YRVIT 5: 55,000 BTU, GS6 75 YRVIT: 80,000 BTU
**R8=1", R12=1-1/2" and R16=2" foam capacity
MODEL
BTU
NUMBER
INPUT
GS6 40 YBVIT
40,000
GS6 50 YBVIT
40,000
GS6 40 YBVIT 2
40,000
GS6 50 YBVIT 2
40,000
GS6 40 YRVIT
50,000
GS6 50 YRVIT
50,000
GS6 50 YRVIT 5
62,500
GS6 75 YRVIT*
80,000
40 and 50-gallon models are supplied with 2", 22-1/2˚ Termination Elbow, plus 2", 3" and 4" screens.
74-gallon model is supplied with 3", 90˚ Termination Elbow, plus 3" screen.
2" & 3" elbows are equal to 5' of vent pipe. 4" elbows are equal to 8' of vent pipe.
Important: Read and follow requirements shown in the Product Manual for Select Power-Vent gas
water heaters dealing with type, placement and length of vent pipe and vent termination, as well as
clearances required to provide adequate combustion and proper ventilation.
Flammable Vapor Ignition Resistant C3 Technology
Corderite Combustion Containment (C3) design meets American National
Standards Institute standards (ANS Z21.10.1) that deal with the accidental or
unintended ignition of flammable vapors, such as those emitted by gasoline.
Covered by four U.S. patents, C3 Technology gas water heaters feature a sealed combus-
tion chamber with air intake screen and a fireproof Corderite flame arrestor built into the
water heater base. Select Power-Vent water heaters are also equipped with a flammable
vapor sensor, which automatically shuts down the blower, Intelli-Vent gas control and hot
surface ignitor if the presence of flammable vapors is detected.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For Additional Technical Information,
PHONE 800-365-0024
STATE WATER HEATERS
500 Tennessee Waltz Parkway, Ashland City, TN 37015
www.statewaterheaters.com
Page 2 of 2
SRGSS00905
®
BTU INPUT
ENERGY
GALLON
PER HOUR
FACTOR CAPACITY
NATURAL
.65
40
40,000
.65
50
40,000
.67
40
40,000
.67
50
40,000
.65
40
50,000
.65
50
50,000
.65
50
62,500
N/A
74
80,000
MAXIMUM VENT DISTANCE
(Total Equivalent Feet)
2" Pipe
3" Pipe
4" Pipe
40'
120'
160'
40'
120'
160'
40'
120'
160'
40'
120'
160'
40'
120'
160'
40'
120'
160'
35'
80'
120'
N/A
30'
100'
SWHR-109982-20M-MSI-0905
POWER-VENT
RECOVERY
90°F RISE
R
GALLONS
VALUE**
A
B
PER HOUR
44
8
63
55
44
8
65
56-3/4
44
16
63
55
44
16
65
56-3/4
53
16
63
55
53
16
65
56-3/4
66
16
65
56-3/4
86
12
66
57
6' POWER CORD
FACTORY
SUPPLIED
1/2" GAS
CONNECTION
Water Heaters
®
DIMENSIONS IN INCHES
C
D
E
F
18-1/2
13
8
49
20
13
8
50-1/4
20-1/2
13
8
49
22
13
8
50-1/4
20-1/2
13
8
49
22
13
8
50-1/4
22
13
8
50-1/4
25-1/2
15
16
50-1/4
C
3/4" MALE WATER
CONNECTIONS
ON 40 AND 50
GALLON MODELS
AND 1" MALE
ON 74 GALLON
E
F
B
D
If flammable vapors
accidentally enter the
combustion chamber,
the Corderite flame
arrestor is designed
so flames burn off the
top surface and
cannot escape down
through the arrestor.
© 2005 State Industries, Inc.
APPROX.
SHIPPING
VENT
WEIGHT
OPTIONS
(LBS)
2, 3 or 4
157
2, 3 or 4
177
2, 3 or 4
166
2, 3 or 4
186
2, 3 or 4
166
2, 3 or 4
186
2, 3 or 4
186
3 or 4
245
A
Printed in U.S.A.

Advertisement

loading

This manual is also suitable for:

Gs6 40 yrvitGs6 50 ybvitGs6 50 ybvit 2Gs6 75 yrvitGs6 50 ybpdt