Hide thumbs Also See for NetXpert XG:

Advertisement

Quick Links

M A N U A L
itnetworks.softing.com
1
itnetworks.softing.com/XG
itnetworks.softing.com/XG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetXpert XG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Softing NetXpert XG

  • Page 1 M A N U A L itnetworks.softing.com itnetworks.softing.com/XG itnetworks.softing.com/XG...
  • Page 2: Table Of Contents

    Scope of delivery �������������������������������������������������������������������������������������������������� 7 Operation ������������������������������������������������������������������������������������������������������������� 7 NetXpert XG main device �������������������������������������������������������������������������������� 7 Automatic shutdown ��������������������������������������������������������������������������������������� 7 Touchscreen ���������������������������������������������������������������������������������������������������� 8 NetXpert XG Active Remote device ���������������������������������������������������������������� 9 SYSTEM SETTINGS ������������������������������������������������������������������������������������������ 10 IP Settings ����������������������������������������������������������������������������������������������������������� 10 Wi-Fi �������������������������������������������������������������������������������������������������������������������� 12 Language ������������������������������������������������������������������������������������������������������������ 14 Date Time �����������������������������������������������������������������������������������������������������������...
  • Page 3 Link Light ������������������������������������������������������������������������������������������������������������ 42 FILE MANAGEMENT �������������������������������������������������������������������������������������� 43 MAINTENANCE ���������������������������������������������������������������������������������������������� 44 RJ45 socket ��������������������������������������������������������������������������������������������������������� 44 Battery ���������������������������������������������������������������������������������������������������������������� 44 Cleaning �������������������������������������������������������������������������������������������������������������� 45 Storage ��������������������������������������������������������������������������������������������������������������� 45 SPECIFICATIONS ��������������������������������������������������������������������������������������������� 46 FREQUENTLY ASKED QUESTIONS ������������������������������������������������������������������� 47 CUSTOMER SERVICE ��������������������������������������������������������������������������������������� 49 GUARANTY STATEMENT ��������������������������������������������������������������������������������� 50 itnetworks.softing.com/XG...
  • Page 4: Introduction

    10 Gigabit Ethernet in accordance with IEEE 802.3. To do this, the NetXpert XG checks for errors in the cabling as well as the signal-to-noise ratio and data transmission capability of Ethernet network cabling up to 10Gbit/s. This ensures that the cabling is able to provide the required bandwidth for the devices connected to the network.
  • Page 5: Safety Instructions

    I N T R O D U C T I O N SAFETY INSTRUCTIONS To ensure safe operation of the NetXpert XG, please carefully follow the instructions and observe the warning information in this manual. Failure to do so may damage the tester and cause serious injury or even death.
  • Page 6: Device Structure

    Active Remote On/Off button Display Vents Micro USB port Micro USB port Connection RJ45 test and RJ45 test and for charger Connection measurement port measurement port for charger SFP and SFP + port for connecting standard SFPs Status LEDs itnetworks.softing.com/XG...
  • Page 7: Scope Of Delivery

    • Holding down the On/Off button switches off the NetXpert XG. Automatic shutdown The NetXpert XG automatically goes to sleep to conserve battery power if there is no input or activity on the device – see chapter Energy for automatic shutdown of the display and the device.
  • Page 8: Touchscreen

    As soon as a text field is activated by tapping, a keyboard appears at the bottom of the screen to make the necessary entries. The type of keyboard depends on the respective requirements of the input field. Figure 3 – Keyboard displayed after activating a text box itnetworks.softing.com/XG...
  • Page 9: Netxpert Xg Active Remote Device

    Tapping on this icon will hide or display the menu on the left Tapping on this icon will take you back to the home screen This icon in the battery display indicates that the NetXpert XG is charged via an external power supply...
  • Page 10: System Settings

    Figure 4 – IP specifications (DHCP – Static IP) In NetXpert XG’s IP setup, network tests can be configured so a DHCP or a fixed IP address is used. The setting can also be made so that a DNS assigned by a DHCP server or a fixed DNS IP address is used.
  • Page 11 SFP+ module (after this selection, the device boots into a special mode) • “WiFi”, connection to the network is established via WLAN. See next page WiFi Scan for settings This window provides additional device information for incorporation into an active network: • MAC address • IPv6 link local address itnetworks.softing.com/XG...
  • Page 12: Wi-Fi

    Figure 7 – Selection of the WiFi network and connection (entering the password) Selection of the WiFi network with which the connection is to be made with password entry (if required). The password display can be selected. itnetworks.softing.com/XG...
  • Page 13 Enable VNC button. It can be used for remote control of device functions or as a screen display aid for presentations or to create screenshots. Disconnect WiFi turns off the connection to the network and starts a new scan. itnetworks.softing.com/XG...
  • Page 14: Language

    Set the current time and date. You can also set whether the time should be displayed in 12- or 24-hour format and the date in the usual formats. This date will be applied to the test protocols and should match the actual test date. itnetworks.softing.com/XG...
  • Page 15: Energy

    To do so, move the brightness slider to the left/right or change the time until standby and auto switch-off when not in use. Reactivation from standby is then possible at any time using the On/Off button or by tapping the screen of the NetXpert XG. itnetworks.softing.com/XG...
  • Page 16: Standards

    Figure 12 – Setting the units and cabling standards Choose whether to display the length in meters or feet. The NetXpert XG supports the two cabling standards. Select TIA568A or TIA568B. This affects the representations of the cabling image. More Options Pressing this button will take you to the second page of the System Settings screen.
  • Page 17: Reports

    This is used to check whether the dimensions and quality of the logo meet the requirements. The logo will be printed on your reports as a company logo as it is displayed here. Please note the possible formats and sizes. itnetworks.softing.com/XG...
  • Page 18: Firmware

    To install an update, save the downloaded file to a USB stick and connect it to the NetXpert XG. From this menu screen, you can then select and install the update file. Follow the instructions on the screen of the device.
  • Page 19: Hardware

    If optical transceivers are plugged in, they will also be read out. The 10G SFP + information is only available in 10G operating mode. About Us Figure 16 – Softing contact information This menu screen lists the worldwide contact information of Softing IT Networks in case you need product support or have other requests. itnetworks.softing.com/XG...
  • Page 20: Licensing

    Licensing Figure 17 – License management The license function allows you to extend the functionality of your NetXpert XG. There are currently three variants: – NetXpert 1G – Qualification up to 1Gbit/s –...
  • Page 21: Cable Test

    Configure the test parameters for the tests to be performed here. Cable Labeling Define how the individual measurements should be named so than can more easily be found and assigned later. Cable Test This menu starts the test runs and displays the results. itnetworks.softing.com/XG...
  • Page 22 Add new cable. Delete cable and test. Edit cable name. Label and attributes such as building, floor, room, etc. can be customized Start Test� Retest Repeat test. No new test is created, the existing one is overwritten. itnetworks.softing.com/XG...
  • Page 23: Projects + Reports

    You can choose from a variety of formats. On the one hand, there is a PDF summary in which one result row is displayed per test run. Or there is also a detailed PDF report which contains one or multiple summary pages, followed by detailed test results. itnetworks.softing.com/XG...
  • Page 24: Cable Type

    NVP and pF/m. Either you take these values from the data sheet of the cable or the NetXpert XG determines the values on a cable of known length (>30m).
  • Page 25 Ethernet speed used for testing. Please note that, depending on the model of the device, fewer options may be available here. If the range is not sufficient for the requirements to be tested, your NetXpert XG can be upgraded at any time via a firmware license.
  • Page 26: Cable Labeling

    Add Cables – the number of cables is specified in the field to the right. If the end of the list is reached during subsequent testing and you start another test run, the device adds a cable names itnetworks.softing.com/XG...
  • Page 27: Cable Test

    • After completing the test, you will see the result on the right and see at a glance if the test has been passed ( – • The addition and deletion of cable names is also possible here using the buttons. Individual cable names can be changed using the function. itnetworks.softing.com/XG...
  • Page 28: Set Reference

    If a distance for the direct connection is terminated with RJ45 plugs, only a referencing of the internal line paths is necessary, as described in the screen under Set reference without test cable� itnetworks.softing.com/XG...
  • Page 29 Set Reference to start the determination of the capacity, which will later be subtracted from the total measured value. The referencing procedure should be repeated when changing the test cables. Figure 25 – Test setup for setting the reference itnetworks.softing.com/XG...
  • Page 30: Network Tests

    NETWORK TESTS The NetXpert XG not only offers the ability to test passive cabling, but also checks active networks for function and locates the errors. It is suitable for use in commissioning an active network and simple diagnostics. Network Tests mode, the NetXpert XG supports copper, fiber, and WiFi media in both IPv4 and IPv6 environments.
  • Page 31: Link Status

    IP address. After tapping on the Start Test button, a DHCP Request is sent� Figure 28 – DHCP test The information received from the DHCP server is displayed and can also be saved directly in PDF format. itnetworks.softing.com/XG...
  • Page 32: Discovery

    Set to Passive / Active Mode� • Active mode: The NetXpert XG actively polls all participants in the network and displays the received data. The NetXpert XG sends Ethernet telegrams to the network� • Passive mode: The NetXpert XG only “listens” to the network and displays all participants it has seen telegrams from.
  • Page 33 Start Test� The list of found stations can also be saved directly in PDF and CSV format. Figure 30 – Network detection (list display with duplicate IP address) itnetworks.softing.com/XG...
  • Page 34: Ping

    Both internal addresses and external domain names can be entered. Ping destinations can be edited via Edit deleted from the list via Remove. The list of the ping results can also be saved directly in PDF and CSV format. itnetworks.softing.com/XG...
  • Page 35: Traceroute

    Three data packets are sent and the corresponding response times are listed. The destination to which the route should be determined can be entered or changed using the Edit Target button. The list of the hops can also be saved directly in PDF and CSV format. itnetworks.softing.com/XG...
  • Page 36: Lldp/Cdp

    N E T W O R K T E S T S LLDP/CDP LLDP CDP The NetXpert XG is capable of detecting and evaluating LLDP (Link Layer Discovery Protocol) and CDP (Cisco Discovery Protocol) telegrams. Figure 33 – LLDP and CDP information Active components such as routers or managed switches can send LLDP or CDP telegrams at regular intervals.
  • Page 37: Vlan

    Using a monitoring port on a managed switch is therefore recommended. Otherwise, depending on the configuration of the switch, it may happen that no telegrams marked with VLAN ID are forwarded to the NetXpert XG and thus no detection can take place. The VLAN information is output in three columns: •...
  • Page 38: Tools

    This facilitates troubleshooting and simple and quick testing of multiple cables. The cable construction is freely selectable in advance, there is a differentiation between shielded and unshielded, straight or crossed, 4-pair or 2-pair versions. If there is a deviation from the set structure, an error message is output. itnetworks.softing.com/XG...
  • Page 39: Port Discovery

    PoE status on the switch port used. Figure 36 – Port detection The NetXpert XG displays the Ethernet speed of the current connection and the other possible speeds of this port. The device performs a PoE evaluation on the port, which can also be called up as...
  • Page 40: Individual Bert Test

    After the set time has expired, the NetXpert XG will show you if the test ran without errors. The pre-set test times depend on the selected Ethernet speed and are based on statistical security (see table, 63% CL).
  • Page 41: Tone Generator

    Tone Generator Find the right cable using the tone generator and a separately available analog inductive receiver (e.g., CableProbe 15 from Softing IT Networks). Figure 38 – Tone Generator Select on which pairs of wires the tone should be output. The individual pairs can be signaled either selectively, or all pairs at the same time.
  • Page 42: Link Light

    N E T W O R K T E S T S Link Light To recognize the connected port on a switch, NetXpert XG can flash the Link LED on the switch port. Figure 39 – Link Light Flashing The connected switch port is detected by a slowly flashing Link LED (0.5Hz).
  • Page 43: File Management

    You can use the filter icons to hide individual file types to improve the overview. You will find different file types on the NetXpert XG. The original test data has the “*.tst” ending and cannot be changed or read externally. Test protocols are usually filed for direct distribution in PDF format.
  • Page 44: Maintenance

    The battery of the NetXpert XG cannot be serviced by the operator. In the event you need to remove the battery, loosen the screws on the back of the NetXpert XG and disconnect the cables from the battery.
  • Page 45: Cleaning

    M A I N T E N A N C E CLEANING Use a clean, damp cloth to clean the NetXpert XG. Before cleaning, disconnect all cables from the device. Otherwise it may damage the device and cause personal injury.
  • Page 46: Specifications

    10 to 90% non-condensing humidity Housing Impact-resistant plastic with rubber coating Dimensions • 245 x 177 x 73mm (main device) • 130 x 177 x 55mm (Active Remote) Weight • 1.2kg (main device) • 0.6kg (Active Remote) Safety compliance Guaranty 1 year itnetworks.softing.com/XG...
  • Page 47: Frequently Asked Questions

    FREQUENTLY ASKED QUESTIONS Q Why does the NetXpert XG show the cable length in red and report that the cable test has failed? A The NetXpert XG tests for compliance with IEEE 802.3 connection specifications. If the cable is longer than 328ft/100m, the NetXpert XG does not perform an Ethernet Speed Certification and declares the test to be faulty.
  • Page 48 A The NetXpert XG can store several thousand cable tests in its internal memory. Q Does the NetXpert recognize XG PoE (Power over Ethernet)? A Yes, the NetXpert XG detects PoE, PoE+ and PoE++, PoE mode and min/max voltages under load.
  • Page 49: Customer Service

    CUSTOMER SERVICE For technical information, see itnetworks.softing.com If you would like to contact our customer service, send an e-mail to support.itnetworks@softing.com itnetworks.softing.com/XG...
  • Page 50: Guaranty Statement

    Subject to changes and errors. All rights reserved. Softing and the Softing logo are trademarks of Softing AG. NetXpert and the NetXpert Logo are trademarks of Softing IT Networks GmbH. All other cited trademarks, product and company names or logos are the sole property of their respective owners.
  • Page 51 +33 1 45172805 info.france@softing.com Italy Softing Italia Srl. Cesano Boscone, Milan +39 02 4505171 info@softingitalia.it Austria Buxbaum Automation GmbH Eisenstadt +43 2682 7045 60 office@myautomation.at For technical information and support, please contact the Softing office in your country. itnetworks.softing.com/contact itnetworks.softing.com/XG https://itnetworks.softing.com...

Table of Contents