CHECKING FOR SUFFICIENT COMBUSTION AIR OR VENTING ISSUES

Draft Test

After successfully lighting the water heater, allow the
unit to operate for 15 minutes and check the draft
hood relief opening for proper draft. Make sure all
other appliances in the area are operating and all
doors/windows are closed when performing the draft
test. Pass a match flame or smoke around the relief
opening of the draft hood. A steady flame or smoke
drawn into the opening indicates proper draft.
If the flame flutters or is blown out, combustion
products are escaping from the relief opening. If this
occurs, do not operate the water heater until proper
adjustments or repairs are made to the vent pipe
system and/or air supply requirements.
Flue Products Vented
to Ouside of Building
Dilution Air
Draft Hood
Dilution Air
(Relief Opening)
Air is drawn in for combustion.
Keep area clean and free from
combustibles and flammable vapors.
Figure 18
External Inspection & Cleaning of
the Base-Ring Filter
1. At least annually check the base-ring filter for any
2. Follow the Lighting Instructions to turn off the water
3. Use a vacuum cleaner with a hose attachment
4. After the base-ring filter has been cleaned, follow
Dilution Air
Cleaning the Combustion Chamber
and Flame-arrestor
Match
1. Follow procedure outlined in "Removing the
2. Use a vacuum cleaner/shop vac to remove all
Outer Door
3. Reassemble following the procedure under
19
dust or debris that may have accumulated on the
filter screen. NOTE: If the water heater is located
in an area that is subjected to lint and dirt, it may
be necessary to check the base-ring filter more
frequently.
heater and allow it to cool for 10 minutes before
attempting to clean the base-ring filter.
to remove any dust or debris that may have
accumulated on the filter. NOTE: If unable to
inspect or clean the base-ring filter, follow the
"Cleaning the Combustion Chamber and Flame-
arrestor" instructions below.
the Lighting Instructions to return the water heater to
service.
Manifold/Burner Assembly" (See page 22).
loose debris in the combustion chamber. Use
compressed air to clear any dust or debris that
may have accumulated in the flame-arrestor.