Low-NOx Commercial Gas Water Heaters
CAPACITY, INPUT AND OUTPUT
BTU
INPUT
MODEL
PER
NUMBER
HOUR
GPG85 540 NEA
U.S. Gallons
540,000
GPV85 540 NEA
U.S. Gallons
GPG85 650 NEA
650,000
GPV85 650 NEA
U.S. Gallons
GPG85 740 NEA
740,000
GPV85 740 NEA
Based on 80% Thermal Efficiency obtained in State engineering laboratories.
To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level.
Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps
DIMENSIONS AND WEIGHT – ALL MODELS
Inches
or
A
B
C
CM
Inches
80-3/4
73
32-1/4
CM
205.1
185.4
81.9
*D dimension is for atmospheric vent size (GPG models).
**E dimension is for direct and sidewall vent size (GPV models).
***Minimum gas supply pipe is 1-1/4". See Reference Manual, Table 7 for gas supply pipe size.
Water heater(s) shall be State Model ________________ or equal, with maximum storage capacity of 85
gallons, an input rating of ___________________ BTU/Hr., a recovery rating of ____ GPH at 100ºF temperature
rise, and minimum thermal efficiency of 80%. Heater(s) shall meet ASHRAE/IESNA 90.1-1999 requirements for
thermal efficiency and standby loss, and meet SCAQMD R1146.2 low-NOx requirements. In addition, heater(s)
shall: 1) Include a powered gas burner, redundant main gas valves, gas pressure regulator and flame inspection
port. 2) Include a high-temperature limit control, dual-bulb thermostat for accurate temperature control and anti-
stacking compensation and a factory-installed AGA rated temperature and pressure relief valve. 3) Be equipped
with 1-1/2" NPT water inlet and outlet and a boiler-type handhole cleanout. 4) Shall be constructed and stamped
in accordance with ASME Boiler and Pressure Vessel Code and be so marked for a maximum working pressure of
160 psi. 5) Have a glass-lined steel tank with multiple anodes for corrosion protection, and polyurethane foam
insulation. 6) Tank shall have a 3-year limited warranty against corrosion as outlined in the written warranty.
Venting: GPG heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting.
GPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting.
Burner and Controls: Burner(s) shall be pre-mix design, with internal FGR and thermal cutoff, separate spark pilot
ignition system, integral blocked flue sensor, glass view port, main gas regulator, automatic gas valve, manual test
cock and manual gas shutoff. Burner(s) must be factory-installed, tested and started by an Authorized State Start-
up Agent before being placed into operation.
For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For Additional Technical Information,
PHONE 800-365-0024
STATE WATER HEATERS
500 Tennessee Waltz Parkway, Ashland City, TN 37015
www.statewaterheaters.com
Page 2 of 2
SCGSS00205
March 2007R
POWERED
BURNER
FIRST
HOUR
RATING
Gallons
GPH
TANK
100° F
or
or
SIZE
RISE
Litres
LPH
85
583
GPH
Litres
321.7
2206.7
LPH
GPH
85
690
LPH
Litres
321.7
2611.7
GPH
85
778
Litres
LPH
2944.7
321.7
DIMENSIONS
D
E
F
G
9
26-1/2
26-1/2
93
22.9
67.3
67.3
236.2
SUGGESTED SPECIFICATION
© 2005 State Industries, Inc.
Printed in U.S.A.
RECOVERY-GALLONS
PER HOUR AT °F
TEMPERATURE RISE
40°F
100°F
140°F
4°C
56°C
78°C
1309
523
374
4954.6
1979.6
1415.6
1579
630
450
5976.5
2384.6
1703.3
1794
718
512
6790.3
2717.6
1937.9
SHIPPING
GAS
CONN.***
WEIGHT
H
I
29-1/2
48-1/2
1
˝
950 Lbs.
-
74.9
123.2
431.8 Kg