Adjustment (Charger Unit); Adjustment Standard (Charger Unit) - Panasonic KX-TCD410RUM Service Manual

Table of Contents

Advertisement

14.3. Adjustment (Charger Unit)

Items
(A)
Charging Check
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.45).

14.4. Adjustment Standard (Charger Unit)

When connecting the Simulator Equipments for checking, please refer to below.
14.4.1. Flow Solder Side View
(A)
Digital Volt Meter
Note:
(A) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) (P.39)
KX-TCD410RU M / KX-TCD410R US / KX-TCD412R UM / KX-TCD412R US / KX-A141RU M / KX-A141RU S / KX-A142RU M / KX-A142RUS
Adjustment
Point
-
1. Connect Charge Contact 12Ω/2W register between charge+ and charge-.
2. Measure and confirm voltage across the regigster is 2.7V ± 0.2V.
12Ω/2W
Procedure
TP4
TP1
TP2
45
Check or
Replace Parts
D1,R1,R2
TP3
PbF

Hide quick links: