Basic Parameter - DZG DVS74 Series Product Manual

Three phase electronic electricity meter
Table of Contents

Advertisement

product manual DVS74

13.3 Basic parameter

Readout via electrical interface.
Access Level
R:
read only
R/W:
read/write
R/W(M):
write only in manufacturer mode (meter cover opened)
Property,
OBIS
value range and default value
Time information
01- 00: 5E.31.00*01
The time information is filed as a seconds index (see Clause 5.1.7).
Enable/disable the active power indication on the display.
Using 'TRUE' the active power output on the display is turned on.
01-00:5E.31.01*01
Value range: TRUE/FALSE
Default value: FALSE
Enable/disable the output of a manufacturer-specific dataset on the INFO inter-face.
Using 'TRUE' the output of the manufacturer-specific dataset is turned on.
01-00:5E.31.01*02
Value range: TRUE/FALSE
Default value: FALSE
Number of magnetic sensor manipulation
events detected.
01-00:5E.31.01*03
Value range: 0 to (2161)
Default value: 0
Enable/disable/reset of manipulation detection
By means of writing using 'TRUE' a status bit possibly set for manipulation
detection will be reset thus enabling the manipulation detection. By means of
writing using 'FALSE' the manipulation detection is disabled and the counter for
01-00:5E.31.01*04
magnetic manipulation detection is set to '0'. The last valid condition is restored
when the voltage supply is reconnected.
Value range: TRUE/FALSE
Default value: FALSE
Enable/disable reset of manipulation detection for mechanical manipulation
(terminal cover or locking pin)
By means of writing using 'TRUE' a status bit possibly set for manipulation
detection will be reset thus enabling the manipulation detection.
01-00:5E.31.01*09
By means of writing using 'FALSE' the manipulation detection is disabled and the
counter for mechanical manipulation detection is set to '0'. The last valid condition
is restored when the voltage supply is reconnected.
Value range: TRUE/FALSE
Default value: FALSE
Number of mechanical manipulation events detected.
01-00:5E.31.01*0A
Value range: 0 to (2161)
Default value: 0
Manufacturer ID
01-00:60. 32.01*01
(see FLAG association)
Device identification
01-00:60.01.00*FF
(see DIN 43863-5)
01-00:00.02.00*00
Device firmware version
01-00: 60. 5A.02*01
Firmware checksum in accordance with MID
01-00:01.08.00*FF
Meter reading for active energy in the direction +A
01-00: 02.08.00*FF
Meter reading for active energy in the direction -A
01-00:20.07.00*FF
Metered voltage for L1
01-00:34.07.00*FF
Metered voltage for L2
01-00:48.07.00*FF
Metered voltage for L3
01-00:10.07.00*FF
Instantaneous active power
01-00:60.05.00*FF
Status word
Access protection via PIN code
01-00:5E.31.01*06
If 'true', the option of data protection via
PIN code is enabled.
01-00:5E.31.01*07
PIN code
01-00:5E.31.01*08
Enabling/disabling the indication of historic consumption values on the display
01-00:01.08.00:60
Historic consumption value for the daily consumption (d)
01-00:01.08.00*61
Historic consumption value for the weekly consumption (w)
Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg
22.02.2019
Type of
access
R
R/W
R/W
R
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R
R
Kopien nur mit Erlaubnis der DZG