1. MAIN SPECIFICATIONS 0. MAIN SPECIFICATIONS ELECTRONIC TIMER Allows to control all parameters REGENERATIONS Delayed or immediate/ programming MIXING VALVE Allows to regulate the residual hardnes INTEGRATED BY-PASS Allows to isolate the system from installation TRANSFORMER Outside EASY TANK SALT FILLING Special for Softener MULTILINGUAL TIMMER English / French / Spanish...
2. INTRODUCTION Your softener RIDER will provide you and your family the The RIDER softeners equipments will avoid you all kind following advantages.
Page 6
For the most part of Europe, hardness is indicater in In RIDER systems the regeneration process starts auto- matically when the systems detects that the exchange ca- French hydrometic degrees, but there are also other pacity is going to finish, the timer incorporated in the sys- measuring units, according to each region.
Page 7
Should this be the case, or if water is to be consumed by persons who must follow a low-sodium diet, it is recom- For the RIDER equipment, please respect the minimum mended to install a household reverse osmosis system to and maximum flow rates indicated in the Technical Char- drink the water.
Page 8
The table below can be used as a guideline to know the increase on sodium concentration in treated water de- pending on feed water hardness: Sodium added Initial hardness by the water in water (ºHF) softener (mgNa/litre)
Width B 360 mm Depth C 530 mm DISTRIBUITED BY: IONFILTER, WATERFILTER, PURICOM Pol. Ind. L’Ametlla Park - c/Aiguafreda, 8 L’Ametlla del Vallès, Barcelona (España) T. 902 305 310 - F. +34 936 934 329 TECHNICAL SERVICE: +34 936 934 309...
24 hours after the goods reception. The RIDER softeners are provided completely ensambled and have the following parts: • Volumetric RIDER valve 850 : Automatic and made of Noryl. With isolating by-pass and mixing screw of resi- dual hardness.
ºC. • In the event that this is deemed RIDER, it can be raised • The system should be installed in a dry environment, a maximum of 1.5 m, provided that the inlet pressure is free of acid vapours.
1. The system should be always installed with the by-pass 5.3 Setting up and maintenance valve supplied. If desired it can be installed a by-pass with 3 valves. The bypass of RIDER systems has two po- sitions. • The system must be periodically sanitised. See ‘Section 8’...
Page 13
NOTA: Inlet and outlet are marked on the valve.Trace the water flow direction to be sure. Plywood IMPORTANTE: Be sure to fit, align and support all plum- Minimum bing to prevent putting stress on the softener valve inlet 2 cm. thick Shim if needed for leveling and outlet.Undue stress from misaligned or unsupported plumbing may cause damage to the valve.
Page 14
This timer is equipped in the upper part of the cabinet. RIDER timers supply a lot of information about the ope- ration of the system.Moreover it allows to adjust all the internal parameters of the system.
MED INTO THE SYSTEM. be cancelled by pressing any key. However the stage can only be cancelled when the motor of the valve stops (the display will be flashing). 7. START UP RIDER Capacity Salt/regen. Capacity 7.1 Hydraulic start-up HIGH EFFICIENCY 1,5 Kg 96ºHFxm...
Page 16
Water going out to the RIDER systems have a residual hardness regulator that drain may be a bit yellowish or brown. This is completely allows to adjust the hardness quantity in the treated wa- normal, since it is due to the preservatives of the resin.
8. MAINTENANCE/SANITIZING The RIDER softeners, being automatic, do not require a complex maintenance. In order to ensure a correct working of the system it is enough to make the following checking from time to time as showed in the table below:...
Page 18
REMOVING INSCRUSTATION: Once a year it is recommended to make a cleaning with Clean Softener (611000), a product specially designed for the cleaning of your softening system. This product, because of its special formulation, will clean the resin eliminating all kind of iron and other remaining metals that represent a contamination and at at the same time it will remove all possible incrustations in the inner pas- sages of the valve.
9. TROUBLESHOOTING GUIDE PROBLEM MAY CAUSE SOLUTION 1. The timer 1. The transformer is not connec- 1. Plug the transformer (power supply). doesn’t work ted. 2. Replace the cable. 2. Electric cable deffective. 3. Revise the installation. 3. No power. 4.
10. MAINTENANCE MANUAL FECHA TIPO DE SERVICIO NOMBRE, FIRMA Y SELLO DEL TÉCNICO AUTORIZADO PUESTA EN MARCHA MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO REPARACIÓN SELLO...
Page 23
10. MAINTENANCE MANUAL FECHA TIPO DE SERVICIO NOMBRE, FIRMA Y SELLO DEL TÉCNICO AUTORIZADO PUESTA EN MARCHA MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO REPARACIÓN SELLO...
11. EQUIPMENT INSTALLATION AND INITIAL OPERATION REGISTRATION SHEET: TECHNICIAN OBSERVATIONS NOTES FOR TECHNICIAN: Read this manual carefully. Should you have any queries, queries please the Technical Assistance Service (TAS) of your distributor. *Result of the installation and start-up: The information marked with (*) must be fulfilled and copied by the tecnhician from the GUARANTEE. CERTIFICATE SHEET.
Page 26
10. MAINTENANCE MANUAL FECHA TIPO DE SERVICIO NOMBRE, FIRMA Y SELLO DEL TÉCNICO AUTORIZADO PUESTA EN MARCHA MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO SELLO REPARACIÓN EXTRAORDINARIA HIGIENIZACIÓN GARANTÍA OTROS MANTENIMIENTO COMPLETO ORDINARIA TÉCNICO REPARACIÓN SELLO...