Strain gage input module with profinet/profibus setup (40 pages)
Summary of Contents for Helm PTM-1100 Series
Page 1
Helm Instrument Company, Inc. 361 West Dussel Drive Maumee, Ohio 43537 USA 419/ 893-4356 Fax: 419/ 893-1371 www.helminstrument.com PTM - 1100 USER MANUAL REV. 1 JUNE 2010 HELM INSTRUMENT CO., INC.
Page 2
Helm within the one (1) year warranty period within specific written authorization to perform repairs. Helm’s obligations and the exclusive remedy of customer under this warranty are limited to repairing or replacing any defective Product at no additional charge and returning Product to customer freight paid.
INTRODUCTION................................ 2 ABOUT PTM-1100 SERIES............................2 BENEFIT ............................... 2 PTM (PEAK TONNAGE MODULE) ......................2 MAIN FEATURES ............................2 OPERATING MODES........................... 2 ALARMS ............................... 2 OTHER FEATURES ............................. 3 USER CONNECTIONS.............................. 3 ...
Operators Manual INTRODUCTION HELM INSTRUMENT CO., INC. manufactures a complete line of load monitoring control systems for use on metal stamping, forging, compaction and assembly presses; cold forming, cold heading, injection molding and die cast machines. Standard or custom transducers and load cells are available for in-die monitoring and transfer or progressive tooling.
PTM-1100 Operators Manual OTHER FEATURES • Jobs Recipe – You create alarm settings per job base and store to Job Recipe for later quick download to setup the system. • Password Protection – The setup screen is password protected to insure only appropriate personnel can bypass the alarms (switch to calibrate more) or change the scale set point.
PTM-1100 Operators Manual TOUCH SCREEN INTERFACE MAIN MENU Main menu allows you to access different area of the system. The PTM-1100™ features a touch screen display for easy navigation and operation of the system. Click or touch on the button you wish to access. JOB –...
PTM-1100 Operators Manual SETUP SCREEN This screen is used to calibrate the system and set the scale value, this screen is password protected. Password is 361. JOB – This displays the current loaded job. PEAK TONNAGE – Displays the peak tonnage value. CAM INPUT –...
PTM-1100 Operators Manual JOB RECIPE SCREEN This screen displays the high and low tonnage set points for each job recipe, and allows you to set, save, and load jobs. CURRENT JOB – Displays the current job. RECIPE – Displays the recipe selected, if pressed you can type the desired recipe (1-20). UP ARROW –...
PTM-1100 Operators Manual PTM MODULE STRAIN GAGE SENSOR INPUT The strain gage sensor wires are connected at the green 5-pole Weidmuller connector at the bottom of the module. Connections include “+ Gage”, “+ Signal”, and “Shield”. For ease of wiring at the connector, it can be removed from the module while making the 5 connections at the screw terminals.
Page 10
PTM-1100 Operators Manual External “Peak Look Window” Timing As stated above, an external timing signal input (“Peak Look Window”) is required for each machine cycle to be monitored. This 24 VDC signal can be generated by a dry contact, prox probe, or PLC output.