Compliance standards Technical support and troubleshooting 1. WELCOME Thank you for choosing this quality Ektor product. This manual is intended to help you install this product in a way that ensures the safety of yourself and others. Whilst this Ektor product is designed...
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 2. OVERVIEW Ektor Generation III platform introduces you to a new era of emergency lighting control. With years in the making, the third generation platform builds on the Ektor product ranges’ increasing quality, reliability and performance.
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 4. INSTALLATION The Ektor Weatherproof Circular can be installed by mounting the product to the ceiling. To install the Circular please follow the steps listed below: Remove the product from the box and inspect it for any damage. If you believe the product to be damaged or otherwise unsound, DO NOT install the product.
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 5. MOUNTING CEILING MOUNT Before you start mounting your Circular, the access point for the terminal block wiring must be chosen. There are three different access points(A, B, C), option C is specificaly for conduit entry. Drill a hole through the Circular base in the desired position.
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 6. TERMINAL BLOCK WIRING OPTIONS The wiring for Circular differs between models and accessories installed. Wiring schematics for the terminal blocks used with the Circulars in the following sections. EV-PEARL & EV-PEARL-PRO Switched Standard External sensor Figure 3: Mains operation only EV-PEARL-EM &...
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 9. USING THE INVERTER WITH A SWITCH A mains rated switch can be wired with this product to turn ON/OFF the non-emergency light in normal use. This does not affect operation in emergency mode. See external switch wiring diagram in section 6 (page 5). NOTE: Emergency models with microwave sensors do not support an external switch.
AS/NZS 2293 or an equivalent standard can have a positive effect on the battery performance as long as 12 discharge cycles per year is not exceeded. 15. POWER AND BATTERY CHARGE The Ektor Generation III platform uses smart battery charging technology which reduces power consumption and increases battery life. Max charge voltage...
Figure 10: Maintained/non-maintained jumper 18. DISCHARGE RATING SELECTION The inverter supports a number of discharge ratings which can be selected by the user. The output from the LED scale based on the discharge rating (see ektor.com.au for output information). HOURS Remove expansion cover...
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 19. ONBOARD MICROWAVE SENSOR SETTINGS DETECTION AREA Detection area can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. RANGE 100% (default) Figure 12: Microwave sensor HOLD TIME The time period you would like to keep the lamp on 100% after the person has left the detection area.
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 22. SELF TEST/ COMMISSIONING INTERVAL PROGRAMMING The self test mode must first be enabled to perform tests by switching the emergency power breaker, or test button in the correct sequence. The test interval is fixed and set to 26 weeks / 182 days. The LEDs indicate the status of the device and which functions are being performed.
IP65 Charger type Smart charge L’ Output 400 W Max. Evolt code Name Max. power Code EV-PEARL-EM-WP Circular Emergency Weatherproof 1808 21 W EV-PEARL-EM-PRO-WP Circular Pro Emergency Weatherproof 1809 29 W EV-PEARL-WP Circular Weatherproof 1810 18 W EV-PEARL-PRO-WP Circular Pro Weatherproof...
If you choose to expose the Ektor emergency products to such harsh operating conditions, Evolt may not honour any warranty on the life of the batteries or the dish. This Ektor emergency product is designed to undergo regular discharge tests but it is recommended that the intervals between consecutive tests are not less than two weeks.
27. TESTING PRECAUTIONS When the Ektor emergency product is permanently connected to the mains supply you will need to allow 24 hours to charge its battery. Once the battery is fully charged you will need to conduct a manual discharge test as per the requirements of AS/NZS 2293 or other relevant standards.
Australian Competition and Consumer Act and other Australian laws. Ektor products are warranted in Australia for a period of 12 months from the date of delivery of the product, provided that the products are properly stored, installed, used and maintained in accordance with the instructions contained within their manual.
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS 30. COMPLIANCE STANDARDS STANDARD TITLE Australian/ New Zealand AS/NZS 2293-3:2005+A1:2010 Emergency escape lighting and exit signs for buildings. Part 3: Emergency escape luminaires and exit signs. Standards AS/NZS 60598-2-22:2005 Luminaires Part 2.22: Particular requirements - Luminaires for emergency lighting (IEC 60598-2-22, Ed.
Page 18
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS...
Page 19
CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS...
Need help?
Do you have a question about the 1808 and is the answer not in the manual?
Questions and answers