Technical Data - Beko CLEARPOINT S040 TWC Control Instructions For Installation And Operation Manual

Compressed air heater, adjustable
Hide thumbs Also See for CLEARPOINT S040 TWC Control:
Table of Contents

Advertisement

Available languages

Available languages

Technical data

Medium:
Compressed air, inert gases
- free from aggressive substances
- dry to moisture-saturated
Housing material: Aluminium, anodized
Powder-coated outside
Bottom area POM
max. operating pressure PS: 232 psi
Pipe connection:
Flow rate at 100 psi:
Differential pressure:
Inlet temperature:
Ambient temperature:
Setting range compressed-air outlet temperature:
Internal safety cut-off temperature:
Max. outside temperature of housing:
Max. compressed-air outlet temperature:
Volume:
0.11 gallon
Voltage:
115 VAC / 50-60 Hz +/- 25%
Power *:
420 (750) W
Protection standard:
IP 54
Weight:
5.3 lb
* at 68°F :
- making-current max 8 A
making-capacity max. 750 W
Increase in the temperature depending on the volume flow
- Compressed-air inlet temperature 68°F
- Adjustment range internal maximum temperature
(compressed-air outlet temperature) 86°F to 140°F
CLEARPOINT S040 / S050 TWC Control
3/8 bei S040
½" bei S050
max. 30 scfm at S040
max. 60 scfm at S050
S040 at 30 scfm : < 2.0 psi
S050 at 60 scfm : < 3.0 psi
35°F to 123°F
35°F to 123°F
86°F to 140°F
183°F
176°F
140°F
Flow rate (scfm)
Accessories
Touch protection :
to be installed on the filter head
Order number.:
XZ CPHZ 001
english
dimensions (inch)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearpoint s050 twc control