ECCO's maintenance-free 6260 Series LED Beacons
feature the latest LEDs and a Pulse8 flash pattern,
producing a warning signal ideally suited to industrial
applications. This cost effective unit has a wide
operating range of 12-80V, making it the perfect light
for use on electric vehicles.
!
WARNING!
Failure to install or use this product according to manufacturer's recommendations may result in property damage, serious injury, and/or death to
those you are seeking to protect!
Do not install and/or operate this safety product unless you have read and understand the safety information
contained
1.
Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to ensure
the safety of you and those you are seeking to protect.
2.
Exercise caution when working with live electrical connections.
3.
This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high current arcing,
which can cause personal injury and/or severe vehicle damage, including fire.
4.
Proper placement and installation are vital to the performance of this warning device. Install this product so that output performance of the
system is maximized and the controls are placed within convenient reach of the operator so that s/he can operate the system without losing
eye contact with the roadway.
5.
Do not install this product or route any wires in the deployment area of an air bag. Equipment mounted or located in an air bag deployment
area may reduce the effectiveness of the air bag or become a projectile that could cause serious personal injury or death. Refer to the
vehicle owner's manual for the air bag deployment area. It is the responsibility of the user/operator to determine a suitable mounting location
ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential head impact.
6.
It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly. In use, the vehicle operator
should ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment doors), people,
vehicles or other obstructions.
7.
The use of this or any other warning device does not ensure all drivers can or will observe or react to a warning signal. Never take the right-
of-way for granted. It is your responsibility to be sure you can proceed safely before entering an intersection, driving against traffic, respond-
ing at a high rate of speed, or walking on or around traffic lanes.
8.
This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws regarding
warning signal devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The manufacturer as-
sumes no liability for any loss resulting from the use of this warning device.
Specifications:
Size:
6262X, 6263X 3.84"(D) x 2.82"(W) x 4.93"(H)
6267X
Weight:
6262X, 6263X 0.8 lb.
6267X
Current draw:
0.5 Amps max. (@+12.8VDC)
Installation & Mounting:
Pipe Mount:
Carefully remove the LED beacon from packaging. Examine the unit for
transit damage. If damage is found, contact the transit company or ECCO.
Do not use damaged or broken parts. Thread into a ½" NPT (pipe) female
fitting. Do not over tighten.
1. Larger wires and tight connections will provide longer service life for components. For high current wires it is highly recommended that terminal blocks or
soldered connections be used with shrink tubing to protect the connections. Do not use insulation displacement connectors (e.g., 3M Scotchlock type con-
nectors).
2. Route wiring using grommets and sealant when passing through compartment walls. Minimize the number of splices to reduce voltage drop. High ambient
temperatures (e.g., under-hood) will significantly reduce the current carrying capacity of wires, fuses, and circuit breakers. All wiring should conform to the
minimum wire size and other recommendations of the manufacturer and be protected from moving parts and hot surfaces. Looms, grommets, cable ties, and
similar installation hardware should be used to anchor and protect all wiring.
3. Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring and devices.
4. Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosion and loss of
conductivity.
5. Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.
6. Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot environments or operated close to their capacity.
Installation and Operation Instructions
2.80" dia x 5.80"
0.8 lb.
Model 6262, 6263, 6267
Flush Mount:
Locate the unit in the desired position on a flat mounting surface, and
using the base as a template, mark the two mounting hole locations.
Drill the holes using a 7/32" (0.219") drill size. Drill a third hole,
exterior to the base to serve as a wire access hole. Mount the unit
using #10 hardware.
Caution: When drilling into any vehicle surface, make sure the area
is free from any electrical wires, fuel lines, vehicle upholstery, etc. that
could be damaged.
Page 1 of 2

Advertisement

Table of Contents
loading

Summary of Contents for Ecco 6260 Series

  • Page 1 Carefully remove the LED beacon from packaging. Examine the unit for transit damage. If damage is found, contact the transit company or ECCO. Do not use damaged or broken parts. Thread into a ½” NPT (pipe) female fitting.
  • Page 2: Wiring Instructions

    LED beacon. 2. If this has not remedied the problem, return product to your local dealer for warranty replacement, or call ECCO Customer Service for assistance. NOTE: THIS UNIT IS REVERSE POLARITY PROTECTED AND WILL NOT OPERATE IF WIRED BACKWARD.
  • Page 3: Especificaciones

    Si se detectan daños, comuníquese con la empresa de transporte o con ECCO. No utilice piezas dañadas o rotas. Enrosque en un accesorio hembra de 1,3 cm (½ pulg) NPT (tubo). No lo sobre apriete.
  • Page 4: Accesorios Y Piezas De Repuesto

    NOTA: ESTA UNIDAD ESTÁ PROTEGIDA CONTRA LA POLARIDAD que efectúe un cambio bajo garantía, o bien comuníquese con el Servicio de INVERTIDA Y NO FUNCIONA SI EL CABLEADO SE CONECTA atención al cliente ECCO para recibir asistencia. EN FORMA INCORRECTA. CONDUCTOR NEGRO...
  • Page 5 Limitación de responsabilidad y garantía limitada del fabricante: El fabricante garantiza que al momento de la compra, este producto cumple con las especificaciones del fabricante para el mismo (disponibles a pedido). El fabricante garantiza además que el presente producto está libre de defectos en sus materiales y en su fabricación.
  • Page 6: Caractéristiques Techniques

    été abîmée dans le transport. Si vous repérez un dommage, contactez la de canalisations d’essence, de garniture souple, etc. qui pourraient être société de transport ou ECCO. N’utilisez pas de pièces cassées ou abîmées. endommagés. Enfilez-le sur un raccord femelle NPT (tuyau) 12,7 mm (½ po.). Ne serrez pas trop.
  • Page 7: Instructions De Câblage

    DEL. 2. Si le problème persiste, renvoyez le produit à votre revendeur local pour le remplacer grâce à la garantie ou appelez le service client d’ECCO pour obtenir de l’assistance. REMARQUE : L’UNITÉ EST PROTÉGÉE CONTRE L’INVERSION DE POLARITÉ...
  • Page 8 Garantie limitée et limitation de responsabilité du fabricant : Le fabricant garantit qu’à la date d’achat ce produit sera conforme aux caractéristiques techniques définies par ses soins (disponibles sur demande) et qu’il est exempt de vices de fabrication et de main-d’œuvre. La présente garantie limitée est valable trente-six (36) mois à compter de la date d’achat.

This manual is also suitable for:

626262636267