Download Print this page

Tek Division Minion User Manual

Personal vaporizer

Advertisement

Quick Links

TEKDIVISION S.R.O.
MinioN
Personal vaporizer
User manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the Minion and is the answer not in the manual?

Questions and answers

Summary of Contents for Tek Division Minion

  • Page 1 TEKDIVISION S.R.O. MinioN Personal vaporizer User manual...
  • Page 2: Let's Get Started

    Press few times the Fire button to turn the chip on. 2. Maintenance The body of the Minion box mod is made of non-corrosive aluminium alloy. Doesn’t need special treatment, however avoid contact whit aggressive liquids like: corrosive house hold cleaners (anticalc) , long exposure with acids ( juice from citrus type or pineapple fruit).
  • Page 3 1. Display 2. FIRE button 3. Charging led indicators RED- Charging BLUE- Charging completed 4. Mini USB 1Amp charging port 5. !!!Warranty sealing!!!
  • Page 4 2. Negative contact screw 3. 510 atomizer contact 4. DOWN button 5. UP button...
  • Page 5 Chip specifications / Evolv Dna 40 Minimum Typical Maximum Output Power 1 Watt 40 Watt Output Voltage 1 Volt 9.0 Volts Output Current, continous 16.0 Amps Output Current, instantaneous peak 23.0 Amps Atomizer Resistance, standard wire 0.16 Ohm 0.7 Ohm 2.0 Ohms Atomizer Resistance, temp.
  • Page 6 Because wattage, not temperature controls vapor volume, large vapor volumes can be produced without unnecessarily high temperatures. Temperature Protection is most helpful if the atomizer begins to dry out, the user pauses during a puff, the beginning or end of the puff, or if the wattage setting is inappropriate for the attached atomizer.
  • Page 7: Operation

    The Dna 40 uses the resistance of the atomizer to calculate the temperature of the heating coil. It continually looks to see whether a new or changed atomizer has been connected. If you are using temperature protection, be careful to only attach new atomizers that have cooled to room temperature to the device.
  • Page 8 Battery indicator: The current state of charge of the battery. Temperature display: When not firing, the maximum heating coil temperature setting. While firing, the actual temperature of the heating coil is displayed. Ohms display: The resistance of atomizer attached to the device. This is measured only when the unit is supplying power to the atomizer.
  • Page 9 seconds. This setting is stored to internal flash memory, and remains if power is removed. Right mode and Left mode: While locked, holding the Fire and UP buttons simultaneously for 5 seconds flips the display. This allows for accommodating to left or right handed use.
  • Page 10 Ohms Too High: The resistance of the atomizer coil is too high for the current wattage setting. If this happens, the Dna 40 will continue to fire, but will not be able to provide the desired wattage. The Ohms Too High message will continue to flash for a few seconds after the end of puff.