Table of Contents

Advertisement

Quick Links

Teamline 5250

Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Teamline 5250

  • Page 1: Teamline 5250

    Teamline 5250 Installation Guide...
  • Page 2: Table Of Contents

    Skype for Business and Exchange requirements Teamline 5250 system specifications Dimensions Connecting Teamline 5250 to peripherals Positioning the Teamline 5250 system Connecting network cables to the Teamline system Connecting the StarLeaf Touch Connecting the camera and microphone Connecting displays and audio Connecting the audio injector...
  • Page 3 Skype for Business Online Outbound Inbound System LED behavior Network port LED StarLeaf Touch Port LED behavior Power and Status LED behavior Camera comparison for Teamline 5250 VHD-V61 Specs Sony SRG-120DH Specs Examples of the maximum field of view VHD-V61 at 2m...
  • Page 4: Before You Install Teamline 5250

    The connectors and pin positions Cable recommendations for room systems HDMI cables XLR cables USB cables Camera cables VISCA cable requirements Pinout Cable color information Teamline 5250 safety and compliance information Installation Ventilation Rack mounting Servicing Power requirements Over-current protection Operating environment Approvals information...
  • Page 5: Prerequisites

    Exchange 2010 SP2 Server Exchange 2013 Server Exchange Online Teamline systems require a room resource mailbox in Exchange and a Skype for Business user account that is associated with the room. For more details about provisioning room system accounts, refer to...
  • Page 6: Teamline 5250 System Specifications

    How to export Root Certification Authority Certificates on the Microsoft website. Teamline 5250 system specifications The following figure shows the connectors on the rear of the Teamline system: Connector Description Power An IEC mains power connector. The Teamline system automatically adjusts to the supply voltage.
  • Page 7: Dimensions

    10/100/1000 Mbit/s auto-sensing Ethernet port to connect to the network Connects to the StarLeaf Touch StarLeaf Controller Dimensions The Teamline 5250 system is designed to fit into a 19" communications rack and occupies 1.5U of height. Dimension Metric Imperial Width 420 mm 16.55 in...
  • Page 8: Positioning The Teamline 5250 System

    1. Using an Ethernet cable, connect the StarLeaf Controller Only connector on the Teamline system to the PoE network port on the rear of the touchscreen controller. The touchscreen controller must connect directly to the Teamline 5250. Do not connect the touchscreen controller through a switch.
  • Page 9: Connecting The Starleaf Touch

    Connecting Teamline 5250 to peripherals Status indicators A device is connected to the Teamline system The connected device is asleep (applicable to the Teamline 5250 system only) Connecting the StarLeaf Touch Using an Ethernet cable, connect the PoE Network port on the rear of the touchscreen to an Ethernet switch in your network.
  • Page 10: Connecting Pronto

    If it has been included with your system, you can use Pronto to share content and audio from devices (such as laptops) during meetings. Connect Pronto to the USB connector on the Teamline system using the USB-A cable, and ensure the other end of the cable is accessible to users to plug into their laptops.
  • Page 11: Mounting Pronto

    Computer In 2 on the rear of the Teamline system to display content locally on room displays and to share content during meetings. It is recommended that you leave a cable within easy access on the meeting room table for this purpose.
  • Page 12: Configuring Teamline 5250

    Connecting the system to Maestro To connect the Teamline system to Maestro: 1. Open the Maestro site. If you haven't created a new room for your Teamline system, see the Maestro management platform guide on the Teamline Knowledge Center.
  • Page 13: Configuring The Proxy Server (Optional)

    Configuring EAP authentication To deploy the Teamline system into a network that is using 802.1x with EAP-TLS authentication: 1. In a browser, enter the Teamline system IP address in the address bar. The Teamline configuration page is displayed. 2. Select Configure 802.1x:...
  • Page 14: Ports And Protocols

    CA. Ports and protocols This is a list of ports and protocols used by the Teamline system. You will need this if your network has Network Access Control (NAC) enabled, which analyzes traffic from the unit for security purposes.
  • Page 15: Inbound

    (also EWS server) 3478 Edge server Used for external (STUN/MSTURN) user access to AV sessions and media (UDP) 5061 Front End server TCP (MTLS) Used for client-to- server SIP traffic for external user access Teamline 5250 Page 15...
  • Page 16: Teamline Systems On External Networks

    PSOM Teamline systems on external networks If the Teamline system is not located on the same local network as the Skype for Business deployment (that is, if it connects using the Edge server), the following ports and protocols also apply.
  • Page 17: Skype For Business Online

    Audio (source port Skype for Business Online 50,000-50,019) servers Other client 50,000-59,999 TCP/UDP Video (source port Skype for Business Online 50,020-50,039) servers Other client 50,000-59,999 Application sharing Skype for Business Online (source port 50,040- servers 50,059) Other client Teamline 5250 Page 17...
  • Page 18: Inbound

    (On the left when looking at the port) Gigabit LED Green for 1000 Mbit/s link, off for 10/100 Mbit/s link or no link (On the right when looking at the port) Teamline 5250 Page 18...
  • Page 19: Power And Status Led Behavior

    There is a problem. This can indicate overheating and/or fan blue failure Camera comparison for Teamline 5250 The following cameras are supported with the Teamline 5250 system: VHD-V61 The VHD-V61 camera is suitable for small to large meeting rooms. If required, it can be mounted upside down.
  • Page 20: Specs

    The SRG-120DH camera is suitable for small to very large meeting rooms. Specs Horizontal field of view: 71° Teamline supports 1080p video calling @ 30fps Digital pan, tilt, and zoom 5x digital zoom, 12x optical zoom Camera dimensions (W x H x D): 153 x 156 x 153 mm...
  • Page 21: Mounting The Camera Upside Down

    2. Connect the supplied VISCA camera control cable to the RS-232 IN connector on the camera. Connect the other end to the VISCA connector on the Teamline system. 3. Connect power to the DC 12V power input on the back of the camera.
  • Page 22: Microphone Selection, Placement, And Setup

    This topic helps you to configure your microphones with the Teamline system. The 5250 system is shipped with a StarLeaf microphone. Features include: Omni-directional pick up pattern 80Hz - 16kHz frequency response >...
  • Page 23: Example Microphone Placement

    Up to two microphones are supported for the Teamline 5250 system. If two microphones are used, position them so that the distance between all participants and the closest microphone is minimized.
  • Page 24: Pinout For Starleaf Microphone Cable

    Pinout for StarLeaf microphone cable Horseshoe table: Round table: Pinout for StarLeaf microphone cable The table below shows the pinout for the XLR-to-mini USB cable that is provided with the StarLeaf Microphone for use with StarLeaf room systems. Teamline 5250 Page 24...
  • Page 25: The Connectors And Pin Positions

    Testing at StarLeaf shows good results with up to 100m of high quality cable. USB cables USB cables greater than 5 meters (16 feet) in length are not recommended. All USB extenders (such as active USB cables) are not supported by StarLeaf. Teamline 5250 Page 25...
  • Page 26: Camera Cables

    VISCA cable requirements Camera cables Teamline systems that include PTZ cameras are provided with 5 meter connection cables. To install cameras further than 5 meters from the system, you can extend cables using a third-party product called an extender. This product effectively carries the media and camera-control signals across a cat 6 Ethernet cable.
  • Page 27: Cable Color Information

    The Teamline 5250 uses side-to-side cooling fans. Allow an adequate space on the sides of the unit to promote a good air flow for cooling of the Teamline 5250. Do not block the fan inlet or outlets. Ensure that the fan intake is not placed inline with the outlet from any other fan or convection cooled device.
  • Page 28: Rack Mounting

    Power requirements Over-current protection Ensure the power supply to the Teamline 5250 is protected by a branch circuit protector rated by a maximum of 20A. Caution—over-current devices must meet applicable national and local electrical safety codes and be approved for the intended application.
  • Page 29: Usa

    Teamline 5250 safety and compliance information The Declaration of Conformity is available on request. Directive 2006/95/EC (Low Voltage Directive): Standard EN 60950-1 Directive 2004/108/EC (EMC Directive): Standard EN 55032 Class A Standard EN 55024 Standard EN 61000 Approved according to UL 60950-1...
  • Page 30: Legal Information

    All other product and company names herein may be trademarks of their respective owners. Document last updated 02 October 2019 Teamline 5250 Page 30...

Table of Contents