INTRODUCTION Congratulations on your selection of the Triminator Rosin TRP Stack! We want to help you to get the best results from your new press and to operate it safely. This manual contains the informa- tion on how to do that; please read it carefully before you set up and use your rosin press.
Injuries and prop- erty damage arising from the use of the Triminator rosin press can be prevented by following all instructions in this manual and on the rosin press. The most common hazards are discussed below, along with the best way to protect yourself and others.
The labels shown here contain important safety information. Please read them carefully. These labels are considered a permanent part of your rosin press. If a label comes off or be- comes hard to read, promptly contact your authorized Triminator dealer for a replacement.
CONTROLS AND COMPONENTS Drip Tech Handle Pull down & up to operate. Steel Frame Cast in NorCal. Aluminum Platens 6 inch by 10 inch with two Drip Tech Pivot heating elements per plat- See graphic at bottom of page Power Button PID Temperature Gauge Controls temp for each platen.
Page 7
CONTROLS AND COMPONENTS (CONT) BEFORE OPERATION Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the rosin press and its operation before you begin using it. Know how to quickly shut off the machine in case of an emergency. Your safety is your responsibility.
STARTING THE ROSIN PRESS CONNECT POWER CORD Connect the Rosin Press power cord to a 20A 120V AC circuit. Optional air or electric power units may be plugged in to the same outlet. Do not connect and disconnect the power cord with wet hands.
ROSIN PRESS OPERATION Program optimal press platen temperature into temperaure control (PID) units. Typically press operation will be between 195 to 220 degrees fahrenheit. To adjust set value temperature on PID control push and hold up arrow button for three seconds.
PIDs further. For this reason we have included the following guide for advanced troubleshooting. PID Standard Operational Parameters The below graphic shows the pre-set advanced settings menu and general setting menu on the Rosin TRP Stack.
Page 11
PID TROUBLESHOOTING (CONT) Troubleshooting the PID If you find a platen or platens are not functioning properly, you may wish to reset the PID. Some of the most common issues people may have are below. Press Doesn’t Reach the Preset Temperature A press that doesn’t reach the preset temperature usually has the PID parameters set up incorrectly.
Page 12
Now the PID is unlocked and the parameters can be reset. Reset the General Settings PID Parameters to Default Values Menu 1 The following settings have been optimized by Triminator engineers to provide the best platen performance. Refer to the PID Manufacturing Settings graph. Follow these settings exactly.
Page 13
PID TROUBLESHOOTING (CONT) Once you have your PID parameters set. Lock your PID Menu to prevent any changes. Relock General Settings PID Menu 1 » Push SET button and hold for 3 seconds. Push SET button to advance through settings until you get to the screen Loc. »...
At your expense, take the Triminator product, part to be replaced, or the equipment on which the part to be replaced is installed, and a proof of purchase to the Triminator deal- er from whom you originally purchased the product, during the dealer’s normal business hours.
Neglect of the periodic maintenance as specified in this manual. » Improper repair or maintenance. » The use of non-genuine Triminator parts and/or products other than those approved by Mosman Machinery Company, Inc. Exposure of the product to chemical agents, sea water, sea breeze, salt or other »...
Need help?
Do you have a question about the Rosin TRP stack and is the answer not in the manual?
Questions and answers